dmode9000 commented Apr 11, 2024

Got two identical DS-2CD2132F-IS cameras. The motion sensor entities isn't working, although the cameras record video upon detecting motion to the internal storage. Notify Surveillance Center activated.

I've attached the log and diagnostic files. If you need any more logs, just let me know.

@maciej-or maciej-or added the bug Something isn't working label Apr 23, 2024
@maciej-or
Copy link
Owner

Thanks for sharing log, that was really helpful. All http headers values of notification event have redundant space on the end. Looks like a firmware bug but I will handle that case in the incoming release.