Enphase Inverters provide either cloud-based or local API access, which allows querying of Solar Generation information.
This module supports either the querying of the public web-based API, or querying of the local inverter API, depending on the configuration supplied.
The following table shows the available configuration parameters for the Enphase EMS module.
Parameter | Value |
---|---|
enabled | required Boolean value, true or false . Determines whether we will poll the Enphase API. |
systemID | required The System ID allocated to your Enphase Envoy inverter. |
userID | required The User ID allocated to your Enphase Envoy installation. |
Parameter | Value |
---|---|
enabled | required Boolean value, true or false . Determines whether we will poll the Enphase API. |
serverIP | required The IP address of the Enphase Envoy Inverter. We will poll this device's HTTP API. |
serverPort | optional Defaults to Port 80. |
"Enphase": {
"enabled": true,
"apiKey": "abcdef",
"systemID": 1234,
"userID": 1234
}
"Enphase": {
"enabled": true,
"serverIP": "192.168.1.2",
"serverPort": 80
}