You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Please provide the following information (all fields are mandatory unless specified otherwise)
Thies Clima
[This is the name of the manufacturer or institution which made the instrument. If there is a manufacturer but you have not been able to confirm this information or there is no official manufacturer, input 'Inapplicable'. If you are creating a generic instrument (e.g. a generic temperature sensor, then input 'Unspecified'.]
Wind measuring technology
[The manufacturer's instrument model range (e.g. WindObserver). If there is no official model range then input 'n/a'.]
4.3120.22.xxx
[Name of the instrument model. If there is no official model name, input 'n/a'.]
Model version
[Name of the sub-model (e.g. 'D', 'v3.2'). If there is no official version/sub-model then input 'n/a'.]
[Alternative name for the model. E.g. Glider Payload CTD alternative name is GPCTD]
Potentiometer-wind-direction-transmitters are equipped with a sliding potentiometer which
offers a theoretically unlimited resolution.
The heating is electronically controlled. A plug-connection is situated in the shaft of the instrument. The instrument is mounted preferably onto a mast or traverse. All main parts are made of anodised aluminium.
[Describes any modifications to the instrument design, such as a manufactured device that has been modified 'in-house' or a plankton net that has been modified since its first description.]
Qualification (if applicable)
[Qualification of the instrument type i.e. a word or words that further describe the instrument type (e.g. 'portable','automated','pressure-compensated','large' etc.). Sometimes these are used in manufacturer names.]
wind vane
[Please indicate what type of instrument it is (e.g. global positioning system, fluorometer, etc.)]
Does the tool describe a series of instruments?
[Does the term describe a manufacturing 'series' of instruments, a 'system' of instruments, an 'individual' instrument or other?]
Reference (if applicable)
[Citation for the instrument (e.g. Hall and Bumpus 1937, 1944). Use if the instrument is manufactured and built according to a design in a paper.]
Short name
[Shortened name of the instrument. This is usually a shortened version of name limited to make, model and version. It can also be an alternative name.]
[Please enter a link to the documentation describing the instrument. This could be a journal reference, manufacturer data sheet, web site, manual etc.]
Mapping to external terminologies (optional)
[Is your submission related to any existing terms in external resources: please enter one or a list of URIs]
ORCID (optional)
[Enter your ORCID if desired]
The text was updated successfully, but these errors were encountered:
roswri
changed the title
NTR: NTR:Thies Clima Wind Direction Transmitter Classic
NTR: NTR:Thies Clima Wind Direction Transmitter Classic [BODCNVS-2573]
Jan 24, 2025
Please provide the following information (all fields are mandatory unless specified otherwise)
Thies Clima
[This is the name of the manufacturer or institution which made the instrument. If there is a manufacturer but you have not been able to confirm this information or there is no official manufacturer, input 'Inapplicable'. If you are creating a generic instrument (e.g. a generic temperature sensor, then input 'Unspecified'.]
Wind measuring technology
[The manufacturer's instrument model range (e.g. WindObserver). If there is no official model range then input 'n/a'.]
4.3120.22.xxx
[Name of the instrument model. If there is no official model name, input 'n/a'.]
Model version
[Name of the sub-model (e.g. 'D', 'v3.2'). If there is no official version/sub-model then input 'n/a'.]
[Alternative name for the model. E.g. Glider Payload CTD alternative name is GPCTD]
Potentiometer-wind-direction-transmitters are equipped with a sliding potentiometer which
offers a theoretically unlimited resolution.
The heating is electronically controlled. A plug-connection is situated in the shaft of the instrument. The instrument is mounted preferably onto a mast or traverse. All main parts are made of anodised aluminium.
[Describes any modifications to the instrument design, such as a manufactured device that has been modified 'in-house' or a plankton net that has been modified since its first description.]
Qualification (if applicable)
[Qualification of the instrument type i.e. a word or words that further describe the instrument type (e.g. 'portable','automated','pressure-compensated','large' etc.). Sometimes these are used in manufacturer names.]
wind vane
[Please indicate what type of instrument it is (e.g. global positioning system, fluorometer, etc.)]
Does the tool describe a series of instruments?
[Does the term describe a manufacturing 'series' of instruments, a 'system' of instruments, an 'individual' instrument or other?]
Reference (if applicable)
[Citation for the instrument (e.g. Hall and Bumpus 1937, 1944). Use if the instrument is manufactured and built according to a design in a paper.]
Short name
[Shortened name of the instrument. This is usually a shortened version of name limited to make, model and version. It can also be an alternative name.]
(https://www.thiesclima.com/en/Products/Wind-measuring-technology-Classic/?art=275
[Please enter a link to the documentation describing the instrument. This could be a journal reference, manufacturer data sheet, web site, manual etc.]
Mapping to external terminologies (optional)
[Is your submission related to any existing terms in external resources: please enter one or a list of URIs]
ORCID (optional)
[Enter your ORCID if desired]