I used the 60MHz ULPI clock as input for the example file. |
In general, you could set it up like this
With constraints
Technically, one should be using |
This is moot at the moment because none of the signals in bank 14 on the Genesys2 connect to a steady clock source. Possibly JTAG_CLK could be used from the external USB to JTAG converter. |
This should be fixed now, I committed a working example for the STLV7325 board, and would leave the adaptation and test for the Kintex board to you. |