[shelly] LOW_BATTERY alarm is raised even battery is full #6659
Labels
bug
An unexpected problem or unintended behavior of an add-on
Comments
markus7017
added
the
bug
An unexpected problem or unintended behavior of an add-on
label
Dec 22, 2019
This is a bug, the check of currentBatValue < 20% fixed with #6764 |
markus7017
added
about to close
Issue potentially resolved and no feedback received
and removed
PR pending
There is a pull request for resolving the issue
labels
Feb 8, 2020
markus7017
removed
the
about to close
Issue potentially resolved and no feedback received
label
Apr 18, 2020
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Log shows
2019-12-20 16:45:25.305 [vent.ItemStateChangedEvent] - Shellyht58f736_BatteryLevel changed from 98.00 to 100.00
2019-12-20 16:45:27.361 [WARN ] [y.internal.handler.ShellyBaseHandler] - shellyht-58f736: Alarm condition: LOW_BATTERY
I have an alarm of LOW_BATTERY with battery at 100%
Details: https://community.openhab.org/t/shelly-binding/56862/720?u=markus7017