Start the gui by typing instamatic
in the command line.
On the left side, a live view of the camera will be shown if the camera can be streamed, such as the Timepix. On the top, there are some fields to change the output of the view. The exposure time for the live view, brightness, and display range can be changed here. Pressing the Save Image
button will dump the current frame to a tiff file in the active directory.
On the right side, there is a pane for file i/o, and the available modules for data collection.
Each of the modules can be turned off (except the io module) in the global.yaml
.
Module: io
This panel deals with input and output of the experimental data.
Directory
Root directory to work in. By default this is C:/instamatic/work_$date/
Sample name and number
This determines the subdirectory where experimental data are stored.
The number is automatically incremenbed when a new experiment is started. Data are never overwritten.
Flatfield
Here the path to the flatfield image can be specified. The default
value is read from config/global.yaml
and can be left blank if no flatfield should be used.
Open work directory
Open the current work directory, which is a combination of the root
directory, sample name, and experiment number. In this case C:/instamatic/work_2017-11-19/experiment_1
. All experimental data for the current experiment will be saved here.
Open config directory
By default %APPDATA%/instamatic/
. The configuration files for the
microscope, camera, and calibration files go here.
Delete last experiment
Sometimes, a data collection will go wrong... Pressing this button will
mark the last experiment directy for deletion. It will not actually delete anything.
Module: sed
Serial electron diffraction (serialED) is a technique to collect diffraction data on a large number of crystals. One diffraction pattern per crystal is collected. These can then be combined for structure determination, or used for screening/phase analysis.
Data collection can be started from the ‘serialED’ tab by pressing the ‘Start Collection’ button. Follow the instructions in the terminal to setup and calibrate the experiment.
Scan area
Radius for the area to scan area for crystals (in micrometer).
Exp. time image
Exposure time for images.
Exp. time diff
Exposure time for diffraction pattern.
Brightness
Default value for the brightness of the focused beam.
Spot size
Spot size to use.
Module: cred
Continuous RED (cRED) data collection can be started from the cRED
tab.
The data collection procedure can be initiated by pressing ‘Start Collection’. The program will then wait for the rotation to start. The moment the pedal is pressed to start the rotation, the program will start the data collection with the specified options. Do not release your foot until after you press ‘Stop Collection’. This will signal the program to stop data collection, and write the images. Images are written in TIFF, MRC, and SMV format. Input files for REDp (.ed3d) and XDS (XDS.INP) are also written.
Exposure time
change the data collection time for each image.
Beam unblanker
If this option is selected, the beam will be automatically unblanked
when data collection starts, and blanked after data collection has finished (i.e. after ‘Stop Collection’ has been pressed)
With this feature, an image of the crystal will be shown every N frames. This is useful to control the position of the crystal in the beam for more reliable and reproducable data collections. This is achieved by applying a small defocus (diffraction focus) to every Nth image. a small defocus of the diffraction focus. If the defocus is large enough, this will show a view of the crystal in the aperture.
Enable Image interval
This option will enable the image interval.
Image interval
Change the interval at which the image will be defocused. For example,
if the value is 10, then every 10th image will be defocused.
Diff. defocus
This is the defocus value to apply. It is better not to make this value
too large, because the larger the difference with the proper diffraction focus, the longer the lenses need to recover. The microscope has to switch to the defocus value, take an image, and back within the time it takes to collect a single image (i.e. 0.5 s in this example).
Toggle defocus
This toggle applies the defocus value, which is used for checking. It
does not affect the data collection.
Other specific cRED modules: cred_fei
, cred_tvips
, autocred
Module: red
Simple module to collect electron diffraction using discrete rotation steps.
Pressing Start Collection
will collect a series of frames with the given tilt step and range. The data collection is then paused, enabling the user to recenter the crystal or finalize the data collection. The program will automatically switch to diffraction mode if it is in image mode, and go back to image mode afterwards. Pressing Continue
will continue from the current point, and collect another series of frames with the given tilt range. Pressing Finalize
will, not unsurprisingly, finalize the data collection, save the data, and write any input files.
Exposure time
The exposure time for each frame in seconds
Tilt range
The total tilt range for the next sequence in degrees
Step size
The step size in degrees
Data are output to .tiff
and .mrc
, including input files to read the data in PETS and REDp.
Module: machine_learning
Running instamatic.learn
on a series of diffraction patterns collected by SerialED will use a deep convoluted neural network to classify the images in 'good' and 'bad' quality, i.e. those with nice looking diffraction spots are separted from those with powder rings, no signal, lots of overlapping crystals.
The data can be loaded into this tab, to navigate back to the selected crystals.
Module: ctrl
This module allows some control over the microscope from the GUI and is updated as needed. At the moment, controls to control the stage position have been implemented, as well as a basic alpha wobbler which will rock the stage back and forth to find the eucentric height for rotation.
This module gives access to several debugging functions, as well as more advanced features.
It also gives the option to run custom python scripts from the GUI. The scripts give access to the ctrl
variable, an instance of TEMController. The scripts are picked up from the directory %APPDATA/Instamatic/scripts
or as defined by the Instamatic
environment variable.
It is also possible to associate an indexing server with the data collection (currently cred
, autocred
), which will attempt to index the data immediately after data collection
There are also functions to collect a flatfield image.
Report status
will report the current status of the microscope to the command line.
Close down
will close down the microscope. It is associated to the script close_down.py
in the scripts directory. It is meant to put the microscope in a state so that the sample can be removed, this means it will neutralize the sample stage, put down the fluorescence screen, maximize the brightness, etc.
Open IPython shell
will open an IPython shell, so that the program state or microscope can be directly interacted with.
Reset triggers
and Empty queue
are for debugging, and probably redundant at this stage.
Module: debug
Module: about