iCubGenova08 S/N:043
During the robot calibration the right hand does not calibrate properly and it gets stuck.
The issue appears without having noticed any critical problem in the previous sessions. It's important to mention that the problem seems recurring.
The impact is severe because we need to start testing soon.
The text was updated successfully, but these errors were encountered:
Please let us know a possible date of the intervention, possibly no later than the 10th of May. cc @lornat75
Sorry, something went wrong.
Hi @ddetommaso, @AntonioAzocar and I replaced the broken tendon in 9th May. We tested the robot and it works properly now!