ergoCub 1.2 S/N:003 β Right Ankle Roll goes in over temperature #1809
Comments
We also had a similar issue on the left ankle. Here the log overheating_left_leg_nonsense.txt The values seems weird:
@valegagge @MSECode are them particular error codes? |
We did not notice that the joint was in HF and we tried to walk. It made a weird motion causing the knee to go in overcurrent. Anyhow, we tested it afterwards and it seemed all fine. |
Thanks for the update since more data are good for the analysis, we know that there could still be issues on the ankles but we're gonna check all asap. |
Hi @S-Dafarra , The issue is due to the electromagnetic noise. In any case, we could improve the documentation regarding the temperature errors. stay tuned! cc @MSECode |
Robot Name π€
ergoCub 1.1 S/N:002
Request/Failure description
We were conducting some walking on ergoCub002, and at certain point the right ankle roll went in hardware fault due to overheating.
There is no video attached since the failure occurs when the robot was hang so we were not recording it.
Detailed context
At the moment of the HF the robot was hang for the approximately 5 minutes and the motors did not seem to be warm at all. The robot interface showed a negative value for the temperature, which most likely correspond to an error with the sensor.
It was fixed just by relaunching the robot.
Additional context
No response
How does it affect you?
It needs to be track and consider for upcoming updates and demos.
cc @S-Dafarra
The text was updated successfully, but these errors were encountered: