ergoCub 1.1 S/N:001

Request/Failure description

After pressing the battery switch in the robot torso nothing happens.
The battery status is not displayed on the robot monitor on the back

Detailed context

This is the only error displayed on the YRI

[ERROR] from BOARD 10.0.1.2 (left_arm-eb2-j0_1) time=9396s 46m 605u : SYS: a service has detected that some CAN boards are still not transmitting. Type of service category is eomn_serv_category_battery. Lost CAN boards are on (can1map, can2map) = ([  ] , [ 2 ]). Total disappearance time: 20001 [ms]

Additional context

No response

How does it affect you?

No response

@github-actions github-actions bot changed the title The robot doesn't switch to battery mode ergoCub 1.1 S/N:001 – The robot doesn't switch to battery mode May 28, 2024
@github-actions github-actions bot added the ergoCub 1.1 S/N:001 ergoCub1.1 platform label May 28, 2024
@AntonioConsilvio
Copy link
Contributor

AntonioConsilvio commented May 29, 2024

Hi @SimoneMic, I investigated the problem yesterday.

Probably, the battery was accidentally forgotten switched on over the weekend which caused the battery to discharge completely.

The BMS (the battery control board) sent the battery into undervoltage protection and so to restore the battery functioning, I connected the charger directly to the battery in order to charge it to the minimum amount needed to overcome the undervoltage threshold.

Now the battery is charged and working properly. Closing!