ergoCub 1.1 S/N:001
Right thumb does not calibrate. Moreover, there are a couple of disconnected cable hanging from it.
I've found the right thumb as in the images below. It does not calibrate and there are some cables coming out from it.
No response
The text was updated successfully, but these errors were encountered:
Hi @PasMarra, the thumb came off (a known problem) from the robot and the cables became disconnected.
@fbiggi glued the thumb to the hand and I reconnected the cables, the robot is working properly for the time being.
Warning
The probable cause of the detached thumb is the manual rotation. Never rotate the finger without loosening the screws first.
However, the piece is being redesigned.
Closing! ✅