-A sample .DAT file [TEST.DAT](http://sccn.ucsd.edu/eeglab/download/TEST.DAT) associated with the sample [TEST.CNT](http://sccn.ucsd.edu/eeglab/download/TEST.CNT) continuous file are available for download for testing purposes. Both the .DAT file and the .CNT files must contain the same number of events (in this case, 100). Neuroscan .DAT files contain data epoch information, so after importing the CNT file into EEGLAB, you must first extract data epochs. To do so, use the menu item <span style="color: brown">Tools → Extract epochs</font>. Select a time window from -0.1 to 0.5, and make sure 100 epochs are generated (if your time window is too large, some epochs at the onset and outset might be removed). Then to import the Neuroscan .DAT file, use the menu item <span style="color: brown">File → Import epoch info → From Neuroscan .DAT info file</span>. After selecting the file to import, a second window appears: