Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Tare always 8388607 weight nan #32

Open
dawidwekwejt opened this issue Dec 9, 2020 · 0 comments
Open

Tare always 8388607 weight nan #32

dawidwekwejt opened this issue Dec 9, 2020 · 0 comments

Comments

@dawidwekwejt
Copy link

dawidwekwejt commented Dec 9, 2020

First time I connected C to WHITE, + to RED and - to BLACK. With this I got always 0 weight, so I changed wiring: C to RED, + to WHITE and - to BLACK. After that I had tared scale and calibrate it with 1L botle. In calibration mode I set 1.000000000000. Why no I got nan value?

Current state

Wiring
UL, UR, LL, LR
C -> RED
+ -> WHITE
- -> BLACK

IMG_20201209_145621

Configuration
Serial Load Cell Converter version 1.2
By SparkFun Electronics
No remote sensor found
System Configuration

  1. Tare scale to zero [8388607]
  2. Calibrate scale [0]
  3. Timestamp [On]
  4. Set report rate [2000]
  5. Set baud rate [9600 bps]
  6. Change units of measure [kg]
  7. Decimals [2]
  8. Average amount [4]
  9. Local temp [Off]
    r) Remote temp [Off]
    s) Status LED [Off]
    q) Raw reading [On]
    t) Serial trigger [On]
    c) Trigger character: [48 / '0']
    x) Exit

Log
1006550,nan,kg,8388607,
1008651,nan,kg,8388607,

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment