TLO probing inaccurate offset #262
Comments
Is this in from the Center finder tab or the Tool length offset tab? FYI I am on holiday and do not have access to a machine to test with so I cannot look into this before I am back home. |
Hello @terjeio Wish you happy New Year! |
Happy new year! You are correct in that the current position is incorrectly used instead of the probed position. I'll fix this and retest when I am back home.
I cannot immediately see this happening from looking at the code, so this has also to wait until I am back. |
I have now uploaded a new edge version with a fix. |
Verifyed with 2.0.43p3 |
sender 2.0.41p8
In TLO probing circle offset aplyed with G10L20P1Z0 which use current position instead of probbing result. I's give some speed and acceleration depended error relaive to actual probbing results.
In my case I get 0.02 - 0.04 mm difference to edge-finder Z mesurement results with reasonable slow feed rate.
I also found, G10L20P1Z0 applyed twice ( shown in terminal window)
@terjeio could you please set the same algoithm as for egde finder