You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
We run our Thanos Ruler in HA with some recording rules and have alerts in place for some of these recording rules. We are experiencing some issues with alerting. We see that the alerts are getting closed and instantly getting created again.
For debugging we created a watchdog alert:
name: ruler-watchdogrules:
- alert: ruler-watchdogexpr: sum(up{namespace="thanos",app_kubernetes_io_component="query"}) by (app_kubernetes_io_component) > 0for: 1mannotations:
summary: Watchdog for Thanos Rulermessage: Watchdog for Thanos Rulerlabels:
severity: warning
This one is always firing and we see the same thing happening.
We don't really see a pattern when these opening and closing of alerts happen. We first thought is was due to some restarts or something. The Alertmanager we use for Thanos Ruler is also used by Prometheus on the same cluster, which doesn't show this behavior.
What you expected to happen:
I would expect that once an alert is created, it's stays open until the alert is solved.
How to reproduce it (as minimally and precisely as possible):
Ruler in HA with 3 instances
Alertmanager in HA with 3 instances
Create a watchdog alert
Anything else we need to know:
The ruler is created via the Prometheus Operator, but deployed in the same namespace as Thanos on the same cluster. The recording rules are working properly and we don't see any gaps in these metrics.
The text was updated successfully, but these errors were encountered:
Hello 👋 Looks like there was no activity on this issue for the last two months. Do you mind updating us on the status? Is this still reproducible or needed? If yes, just comment on this PR or push a commit. Thanks! 🤗
If there will be no activity in the next two weeks, this issue will be closed (we can always reopen an issue if we need!). Alternatively, use remind command if you wish to be reminded at some point in future.
Thanos, Prometheus and Golang version used:
Thanos version: 0.21.1
Prometheus version: 2.27.1
Alertmanager: 0.22.2
Object Storage Provider:
GCS
What happened:
We run our Thanos Ruler in HA with some recording rules and have alerts in place for some of these recording rules. We are experiencing some issues with alerting. We see that the alerts are getting closed and instantly getting created again.
For debugging we created a watchdog alert:
This one is always firing and we see the same thing happening.
We don't really see a pattern when these opening and closing of alerts happen. We first thought is was due to some restarts or something. The Alertmanager we use for Thanos Ruler is also used by Prometheus on the same cluster, which doesn't show this behavior.
What you expected to happen:
I would expect that once an alert is created, it's stays open until the alert is solved.
How to reproduce it (as minimally and precisely as possible):
Anything else we need to know:
The ruler is created via the Prometheus Operator, but deployed in the same namespace as Thanos on the same cluster. The recording rules are working properly and we don't see any gaps in these metrics.