Windows named pipes hits unreachable code during read operation #1819
Comments
last version 1.0.1 |
Even if it's a similar bug #1660. In any case, it is not fixed. |
I can not understand. If |
Here https://github.com/akahan/mio/tree/v1.0.1-dev is the code that I used to temporarily solve this problem. |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
The error occurs at this location:
mio/src/sys/windows/named_pipe.rs
Line 871 in 4a5114e
In
io.read
comesState::Err
with:Err The pipe has been ended. (os error 109)
This appears on both Windows 11 and Windows 10.
It reproduced almost stably when closing the laptop lid with running service and client, apparently after switching to standby mode.
If I handle this state and simply exit the
read_done
method without callingunreachable
(and assign the same error state toio.read
again. Perhaps it's better not to do this?), everything continues to work, seemingly normal. Any comments guys?My environment works like this:
The Windows service creates a named pipe as an administrator (both
PipeMode::Bytes
andPipeMode::Message
modes were tested). After which the client connects to it and sends a message 2 times per second and reads the response.The text was updated successfully, but these errors were encountered: