Another heat pump protocol observed in #45 with an Austria Email BWWP 200 WT SMART COZY heat pump.
Message Format
ID LEN PAYLOAD CHECKSUM
C1 23 2E00230018001800150000000000000000000000008200000000454528CB000E0111 44
C2 22 32120000001000062C01D0020000003A211E0C0C000000004E450000060422013E FA
43 2D 0000071D0000000000000000071D0000EEB2390000000000000000000B4C105AFB27FB250B1B000000000000 57
Identifier
1 byte message identifier
1 byte payload length (length field and payload size)
1-254 bytes payload
1 bytes checksum
Checksum
Is a regular XOR checksum on length field plus payload:
staticuint8_tgenerateNextChecksum(constuint8_t* buffer, uint8_t length){
int desiredChecksum = 0;
// checksum is calculated on length field and payloadfor (size_t i = 0; i < length; i++)
{
// XOR the current byte with the accumulated checksum
desiredChecksum ^= buffer[i];
}
return desiredChecksum;
}
Messages
HMI Message (194)
Byte Number
Example (dec)
Purpose/Function
Other Information
0
34
Length Field
1
50
Water Target Temperature
2
18
Operation Mode, Operation Type
See table below
3
0
?
4
0
?
5
0
?
6
16
?
7
0
?
8
6
?
9
44
?
10
1
?
11
208
?
12
2
?
13
0
?
14
0
?
15
0
?
16
59
Time Seconds
17
33
Date Day, Month
18
30
Date Year, Month
19
12
Time Minutes
20
12
Time Hours
21
0
?
22
0
?
23
0
?
24
0
?
25
78
?
26
69
?
27
0
Error Number Requested
28
0
Error Request Id
29
6
?
30
4
?
31
34
?
32
1
?
33
62
?
Byte No. 2: Operation Mode
Bit Number
Purpose/Function
Other Information
0 - 3
Operation Mode
Interpreted as integer, 0 == Auto, 1 == ECO ON, 2 == ECO OFF, 9 == BOOST
4 - 7
Operation Type
Interpreted as integer, 1 == Timer, 4 == Continious
Help Required:
TODO: OperationMode: Boost, Eco On, Eco Off, Auto, Absence
TODO: Exhaust Fan Config: (Only in EXT/INT): STOP, LOW-SPEED, HIGH-SPEED
TODO: Heating Element Enabled On/Off
TODO: PV Mode allowed On/Off
Main Message (193)
Byte Number
Example (dec)
Purpose/Function
Other Information
0
35
Length Field
1
46
?
2
0
?
3
35
?
4
0
?
5
24
?
6
0
?
7
24
?
8
0
?
9
21
?
10
0
?
11
0
?
12
0
?
13
0
?
14
0
?
15
0
?
16
0
?
17
0
?
18
0
?
19
0
?
20
0
?
21
0
?
22
130
?
23
0
?
24
0
?
25
0
?
26
0
?
27
69
?
28
69
?
29
40
?
30
203
?
31
0
?
32
14
?
33
1
?
34
17
?
Help Required:
To identify this attributes within the message, try to locate the information within the HMI controller,
and provide a photo of the HMI controller together with a dump of the main message. We should find the values shown in the HMI controller within the message.
For determining the values from super secret menu, you change a setting in the super secret menu of the hmi controller and watch the change of main message.
TODO: Hot Water Temp
TODO: Input Air Temp
TODO: Lower Evaporator Temp
TODO: Upper Evaporator Temp
TODO: PWM Level Settings (Super Secret Menu)
TODO: Status Bitmask (Fan On/Off, Defrost On/Off, PV On/Off, Solar On/Off, HeatElement On/Off, HeatPump On/Off, Boiler Backup On/Off)
TODO: Current Fan PWM Level
TODO: Min T Target (Super Secret Menu)
TODO: Anti-Legionella T Target (Super Secret Menu)
TODO: Error Codes
TODO: Wattage Heat Element (Super Secret Menu)
TODO: Boiler Capacity (Super Secret Menu)
TODO: Brand (Super Secret Menu)
TODO: Setting Bitflags (Super Secret Menu)
Energy Message (67)
Byte Number
Example (dec)
Purpose/Function
Other Information
0
45
Length Field
1
0
?
2
0
?
3
7
?
4
29
?
5
0
?
6
0
?
7
0
?
8
0
?
9
0
?
10
0
?
11
0
?
12
0
?
13
7
?
14
29
?
15
0
?
16
0
?
17
238
?
18
178
?
19
57
?
20
0
?
21
0
?
22
0
?
23
0
?
24
0
?
25
0
?
26
0
?
27
0
?
28
0
?
29
11
?
30
76
?
31
16
?
32
90
?
33
251
?
34
39
?
35
251
?
36
37
?
37
11
?
38
27
?
39
0
?
40
0
?
41
0
?
42
0
?
43
0
?
44
0
?
Help Required:
To identify this attributes within the message, try to locate the information within the HMI controller,
and provide a photo of the HMI controller together with a dump of the energy message. We should find the values shown in the HMI controller within the message.