This documents lists all the measurements that are done on the PRP1 for design characterisation.
The measurements were done on two separate units, results are published in folders
Verifies the gain errors across the frequency span\
Equipment used:
- Siglent SDS804X HD Oscilloscope
- Siglent SDG1032X HD Generator
Settings:
- 10Hz to 10MHz
- 10 point/decade
- 100mV peak to peak
- 0V offset
- Frequency mode: Linear
- DUT input CH1
- DUT output CH3
- Load 50 Ohm
Pass criteria: 1dB maximum deviation between minimum and maximum of the gain plot
Note: Crossover frequency is ~ 100 KHz
Note: 1.3:1 is 0.77 or -2dB
Verifies the 1.3:1 probe attenuation\
Equipment used:
- Siglent SDS804X HD Oscilloscope
- Siglent SDG1032X HD Generator
Settings on generator:
- 10MHz sine wave
- 100mV peak to peak
- 0V offset
- Load 50 Ohm
- Using 1:1 setting on the PRP1
Pass criteria: 5% maximum deviation between RMS and Peak to peak value of CH1 and CH3\
Verifies the noise figure of the PRP1\
Settings:
- PRP1 zeroed-out
- PRP1 powered by lab linear power supply
- PRP1 input shorted by SMA shoring plug or 50Ohm load
- 2 mV/div on CH1
- 1:1 probe on CH1
- CH1 terminated with a 50 Ohm terminator
- 2.6 mV/div on CH3
- 1.3:1 probe on CH3
- 1 ms/div time scale
- 20MHz bandwidth limit
Pass criteria:
Verifies the 1.3:1 probe attenuation on DC\
Equipment used:
- Siglent SDS804X HD Oscilloscope
- Siglent SDG1032X HD Generator
Settings:
- PRP1 zeroed out on Oscilloscope with 0V input
- 10 Hz square wave
- 100mV peak to peak
- 0V offset
Pass criteria:
Measured 100mV peak to peak on the oscilloscope on CH1 and CH3
Two measurements are 5% within each other
Verifies the +/-24V Cancellation range of the PRP1\
Equipment used:
- Siglent SDS804X HD Oscilloscope
- Rigol DP832 Power supply
Settings:
- PRP1 zeroed-out after each change of the voltage on power supply
- Set up 5V, 12V, 24V with 0.1A current limit on power supply
- Flip BNC to banana adapter and repeat measurement
Pass criteria: PRP1 can be adjusted to less than 100mV measured on the oscilloscope Output current of the power supply is less than 1mA
Verifies the active signal range of the PRP1\
Equipment used:
- Siglent SDS804X HD Oscilloscope
- Siglent SDG1032X HD Generator
Settings:
- PRP1 zeroed out on Oscilloscope with 0V input
- 10 KHz square wave
- 500mV peak to peak
- 0V offset
Pass criteria: Measured 500mV peak to peak on the oscilloscope
Verifies the 50KOhm input impedance in DC conditions of the PRP1\
Equipment used:
- Siglent SDS804X HD Oscilloscope
- HP 34401A multimeter
Settings:
- PRP1 zeroed out on Oscilloscope with 0V input
- resistance measurement auto range
Pass criteria: 50Kohm +/- 2% measured on DMM
Verifies the minimum 2 GHz bandwidth of the PRP1\
Equipment used:
- LiteVNA
- Rigol DP832 Power supply
- MegiQ VNA calibration kit
- LiteVNA SS405 Coax cables
Settings:
- 10 MHz to 3 GHz sweep
Pass criteria: 1dB maximum deviation between minimum and maximum of S12 up to 2 GHz
Nominal gain is -2dB +/- 1dB
Note: 1.3:1 is 0.77 or -2dB
Verifies the minimum 2 GHz bandwidth of the PRP1 with a more accurate VNA\
Note: Minimum frequency setting of the VNA is 400 MHz
Equipment used:
- MegiQ VNA-0440e
- Rigol DP832 Power supply
- MegiQ VNA calibration kit
- LiteVNA SS405 Coax cables
Settings:
- 400 MHz to 3 GHz sweep
- S11,S12 measured
Pass criteria: 1dB maximum deviation between minimum and maximum of S12 up to 2 GHz
Nominal gain is -2dB +/- 1dB
Equipment used:
- LiteVNA
- Rigol DP832 Power supply
- MegiQ VNA calibration kit
- LiteVNA SS405 Coax cables Settings:
- 10 MHz to 3 GHz sweep
Pass criteria: None S parameters provided for reference
Equipment used:
- MegiQ VNA-0440e
- Rigol DP832 Power supply
- MegiQ VNA calibration kit
- LiteVNA SS405 Coax cables
Pass criteria: VSWR < 1.5 up to 2 GHz
This is equivalent to Return loss < -13dB
Or capacitive loading of ~ 0.5pF
Verifies the high freqency noise content of the PRP1\
2 GHz scope should be used for ideal conditions, but I don't have access to one
Equipment used:
- Keysight MSOX 3104T Oscilloscope
- Keithley 2221A Power supply Settings:
- PRP1 zeroed-out
- PRP1 powered by lab linear power supply
- PRP1 input shorted by SMA shoring plug or 50Ohm load
- 2 mV/div on CH1
- 1:1 probe on CH1
- 2.6 mV/div on CH3
- 1.3:1 probe on CH3
- 20 us/div time scale to get the full samplerate and bandwidth
- 50 Ohm input CH1 and CH3
Pass criteria: TBD
- Siglent SDS804X HD Oscilloscope
- Rigol DP832 Power supply
Settings:
- 5V, 0.1A
- PRP1 zeroed-out
Pass criteria: Power consumption less than 20mA