Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

VE.Smart Networking #196

Open
pmknowles opened this issue Jul 15, 2024 · 3 comments
Open

VE.Smart Networking #196

pmknowles opened this issue Jul 15, 2024 · 3 comments
Labels
enhancement New feature or request

Comments

@pmknowles
Copy link

I have a Smart Shunt connected via Bluetooth to a Smart Solar MPPT 250/60 which is connected by a USB VE-Direct cable and a Raspberry Pi running Venus. There's also a RS Smart Inverter. The Smart Shunt sends the data to the charger but there doesn't seem to be a way to get it into node-red (or into the Remote Console for that matter) unless I'm missing something.

Node-red nodes with data from the VE.Smart bluetooth network

Read the VE.Smart Networking manual

image

@pmknowles pmknowles added the enhancement New feature or request label Jul 15, 2024
@dirkjanfaber
Copy link
Collaborator

Did you try getting the data with https://flows.nodered.org/node/node-red-contrib-victron-vedirect-usb ?

@pmknowles
Copy link
Author

Did you try getting the data with https://flows.nodered.org/node/node-red-contrib-victron-vedirect-usb ?

Missing the point. The data is available via the CANBus in VRM but not avaiable in the Node. I get it from the VE.Bus but not all data points are available there either.

@dirkjanfaber
Copy link
Collaborator

Indeed getting the feeling that I am missing something here too. I am not a magician that knows the ins and outs of your system. I do know that system data in VRM is not available via the CAN bus. The only information that goes into VRM is running via the underlying dbus and posted to VRM via vrmlogger or real-time via a MQTT connection.

All of that information (on the dbus) can be fetched via the custom input node, if you know the right service and path on the dbus. Most paths are also linked using one of the more specific nodes.
Besides this, extra information on the system can also be obtained using a USB VE-Direct cable, which can be accessed using the named node-red-contrib-vedirect-usb node. Hence that suggestion.

VE.Smart networking is not available from Venus, so the information on that network can't be accessed using any node.

But that doesn't help you much, so lets try to get the data that you want to have. What data points exactly are you looking for? Please provide some screenshot clarifying it. "The data" isn't that helpful.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment