Prevent false readings in IRAPT during unvoiced periods #2

Open
jessa0 opened this issue Oct 15, 2021 · 2 comments
Open

Prevent false readings in IRAPT during unvoiced periods #2

jessa0 opened this issue Oct 15, 2021 · 2 comments
Labels
C-enhancement Category: An issue proposing an enhancement or a PR with one.

Comments

@jessa0
Copy link
Contributor

jessa0 commented Oct 15, 2021

When no speech is present (or during consonants of speech) the IRAPT algorithm currently still reports pitch data and spikes to the maximum of its configured pitch range. irapt-rs issue #1 may be a potential fix to this.

@jessa0
Copy link
Contributor Author

jessa0 commented Oct 18, 2021

partially mitigated in 4c53ddc, which at least makes the graph more readable in the presence of outliers.

@jessa0 jessa0 added the C-enhancement Category: An issue proposing an enhancement or a PR with one. label Oct 18, 2021
@jessa0
Copy link
Contributor Author

jessa0 commented Oct 23, 2021

ca52520 also mitigates this, as it filters out the default 880Hz output of IRAPT during unvoiced periods.