The discussion on this page is mostly about the NIFTI-1 file format. Tensors in other file formats supported by ITK (such as MetaIO or NRRD) may also work, but are less likely to have been tested. If you have used other formats successfully and have example code to include below, please let us know.
The NIFTI file should be 5D and have dimensions [X,Y,Z,1,6] where X,Y,Z are the number of voxels. The intent code should be set to NIFTI_INTENT_SYMMATRIX. The NIFTI format specifies a symmetric matrix in lower triangular format. For the DT, this means the six components of the image are ordered [dxx, dxy, dyy, dxz, dyz, dzz].
The header describes the transformation of the image voxels into physical space, as for scalar images. In ITK, this is called the "Direction" matrix, and is always a rigid transform (affine transforms, like those defined in the NIFTI "sform", are not supported).
The correct convention for the tensor coordinate system is software dependent, and extracting them from the raw scanner data has required considerable effort from the creators of tools like dcm2niix
. See here for discussion and sample data.
On the post-processing side, see here and here for bvec requirements in FSL and here for an example using Camino.
Errors in the bvecs can go unnoticed because invariant scalar characteristics like fractional anisotropy and mean diffusion are not affected, but tractography will be affected.
The examples below describe how to convert the tensors into the correct file format for ANTs.
To work with ANTs, the tensors should be in index space, such that a tensor can be correctly reoriented into physical space by applying the direction matrix.
dtifit -k dwi.nii.gz -o dti -m mask.nii.gz -r bvecs -b bvals --save_tensor
This produces a tensor component image dti_tensor.nii.gz
which is stored as a 4D NIFTI image in upper-triangular order. This needs to be converted into a 5D lower-triangular image for ANTs by first splitting the 4D image into 3D components, and then labeling them by their matrix indices [xx,xy,xz,yy,yz,zz]. Then ImageMath
can combine them into a NIFTI_SYMMATRIX image.
ImageMath 4 dtiComp.nii.gz TimeSeriesDisassemble dti_tensor.nii.gz
i=0
for index in xx xy xz yy yz zz; do
mv dtiComp100${i}.nii.gz dtiComp_${index}.nii.gz
i=$((i+1))
done
ImageMath 3 dtAnts.nii.gz ComponentTo3DTensor dtiComp_
As stated here, FSL always requires a radiological (left-handed) coordinate system for bvecs, regardless of whether the DWI image is radiological or neurological. You can check the orientation of the data with:
fslorient dwi.nii.gz
If this reports RADIOLOGICAL
, and output of dtifit
looks correct in fsleyes
, then the tensors should be compatible with ANTs. If fslorient
reports NEUROLOGICAL
, the bvecs still have to be radiological for FSL, but then image and bvec coordinate system will not agree and the tensors will not be correctly oriented by ANTs.
The procedure is similar to FSL but the dwi2tensor command uses a different component ordering, so the iteration over components is different:
ImageMath 4 dtiComp.nii.gz TimeSeriesDisassemble dt.nii.gz
i=0
for index in xx, yy, zz, xy, xz, yz; do
mv dtiComp100${i}.nii.gz dtiComp_${index}.nii.gz
i=$((i+1))
done
ImageMath 3 dtAnts.nii.gz ComponentTo3DTensor dtiComp_
modelfit -model ldt_wtd -inputfile dwi.nii.gz -schemefile a.scheme \
-brainmask mask.nii.gz -outputfile wdt.Bdouble
dt2nii -inputfile wdt.Bdouble -header dwi.nii.gz -outputroot nifti_
This will produce nifti_dt.nii.gz, which is in the required format. The bvecs should agree with the voxel ordering of the image. Camino uses the voxel space internally and uses the NIFTI header to convert streamline tracts into physical space.