Fix slide_2 action sensor always triggered by any command (T5-3C-86) #1252

Closed
catalinescu-sudo opened this issue Nov 1, 2023 · 5 comments
Closed
Assignees
Labels
bug Something isn't working
Milestone

Comments

@catalinescu-sudo
Copy link

Hi, I want to use capabilities of T5-3C-86 with slide_1 and slide_2. The problem is that everytime I turn on or off one of the light channels of the device, also "slide_2" action is received by home assistant, and this disturbs my other plans, so I can't make usable automations with this function. Is a bug perhaps of the new update? Thank you!

@catalinescu-sudo catalinescu-sudo changed the title Slide_2 in action sensor always triggered by any command (T5-3C-86) Slide_2 action sensor always triggered by any command (T5-3C-86) Nov 1, 2023
@AlexxIT AlexxIT added the debug logs Waiting debug logs label Nov 1, 2023
@AlexxIT
Copy link
Owner

AlexxIT commented Nov 1, 2023

You need to collect debug logs with this problem

@catalinescu-sudo
Copy link
Author

home-assistant_sonoff_2023-11-01T14-56-29.455Z.log
Is this what you need?

@catalinescu-sudo
Copy link
Author

Another observation: this behavior is happening when I use switches in home assistant interface. If I press actual physical switches or in ewelink app is not happening, is working correctly.

@AlexxIT AlexxIT changed the title Slide_2 action sensor always triggered by any command (T5-3C-86) Fix slide_2 action sensor always triggered by any command (T5-3C-86) Nov 2, 2023
@AlexxIT AlexxIT added bug Something isn't working and removed debug logs Waiting debug logs labels Nov 2, 2023
@Opontios
Copy link

Another observation: this behavior is happening when I use switches in home assistant interface. If I press actual physical switches or in ewelink app is not happening, is working correctly.

I also have noticed that if you trigger the lights off as in a "all off" group command, the slide sensor gets triggered. I have automations created with slide triggers that are executed while sending the all off command to the group that has the T5 included.

@AlexxIT AlexxIT added this to the v3.5.4 milestone Jan 4, 2024
@AlexxIT AlexxIT self-assigned this Jan 4, 2024
@AlexxIT
Copy link
Owner

AlexxIT commented Jan 4, 2024

@AlexxIT AlexxIT closed this as completed Jan 4, 2024