-
Notifications
You must be signed in to change notification settings - Fork 493
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
feat(e2e-tests): Add fault injection tests for properties operations
- Loading branch information
1 parent
ef1df70
commit d753f3a
Showing
1 changed file
with
223 additions
and
0 deletions.
There are no files selected for viewing
223 changes: 223 additions & 0 deletions
223
e2e/test/iothub/properties/PropertiesFaultInjectionTests.cs
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,223 @@ | ||
// Copyright (c) Microsoft. All rights reserved. | ||
// Licensed under the MIT license. See LICENSE file in the project root for full license information. | ||
|
||
using System; | ||
using System.Threading; | ||
using System.Threading.Tasks; | ||
using FluentAssertions; | ||
using Microsoft.Azure.Devices.Client; | ||
using Microsoft.Azure.Devices.E2ETests.Helpers; | ||
using Microsoft.Azure.Devices.E2ETests.Helpers.Templates; | ||
using Microsoft.Azure.Devices.Shared; | ||
using Microsoft.VisualStudio.TestTools.UnitTesting; | ||
|
||
namespace Microsoft.Azure.Devices.E2ETests.Properties | ||
{ | ||
[TestClass] | ||
[TestCategory("E2E")] | ||
[TestCategory("IoTHub")] | ||
[TestCategory("FaultInjection")] | ||
public class PropertiesFaultInjectionTests : E2EMsTestBase | ||
{ | ||
private static readonly string s_devicePrefix = $"E2E_{nameof(PropertiesFaultInjectionTests)}_"; | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceUpdateClientPropertiesTcpConnRecovery_Mqtt() | ||
{ | ||
await Properties_DeviceUpdateClientPropertiesRecoveryAsync( | ||
Client.TransportType.Mqtt_Tcp_Only, | ||
FaultInjection.FaultType_Tcp, | ||
FaultInjection.FaultCloseReason_Boom, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceUpdateClientPropertiesTcpConnRecovery_MqttWs() | ||
{ | ||
await Properties_DeviceUpdateClientPropertiesRecoveryAsync( | ||
Client.TransportType.Mqtt_WebSocket_Only, | ||
FaultInjection.FaultType_Tcp, | ||
FaultInjection.FaultCloseReason_Boom, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceUpdateClientPropertiesGracefulShutdownRecovery_Mqtt() | ||
{ | ||
await Properties_DeviceUpdateClientPropertiesRecoveryAsync( | ||
Client.TransportType.Mqtt_Tcp_Only, | ||
FaultInjection.FaultType_GracefulShutdownMqtt, | ||
FaultInjection.FaultCloseReason_Bye, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceUpdateClientPropertiesGracefulShutdownRecovery_MqttWs() | ||
{ | ||
await Properties_DeviceUpdateClientPropertiesRecoveryAsync( | ||
Client.TransportType.Mqtt_WebSocket_Only, | ||
FaultInjection.FaultType_GracefulShutdownMqtt, | ||
FaultInjection.FaultCloseReason_Bye, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceReceivePropertyUpdateTcpConnRecovery_Mqtt() | ||
{ | ||
await Properties_DeviceReceivePropertyUpdateRecoveryAsync( | ||
Client.TransportType.Mqtt_Tcp_Only, | ||
FaultInjection.FaultType_Tcp, | ||
FaultInjection.FaultCloseReason_Boom, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceReceivePropertyUpdateTcpConnRecovery_MqttWs() | ||
{ | ||
await Properties_DeviceReceivePropertyUpdateRecoveryAsync( | ||
Client.TransportType.Mqtt_WebSocket_Only, | ||
FaultInjection.FaultType_Tcp, | ||
FaultInjection.FaultCloseReason_Boom, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceReceivePropertyUpdateGracefulShutdownRecovery_Mqtt() | ||
{ | ||
await Properties_DeviceReceivePropertyUpdateRecoveryAsync( | ||
Client.TransportType.Mqtt_Tcp_Only, | ||
FaultInjection.FaultType_GracefulShutdownMqtt, | ||
FaultInjection.FaultCloseReason_Bye, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
[LoggedTestMethod] | ||
public async Task Properties_DeviceReceivePropertyUpdateGracefulShutdownRecovery_MqttWs() | ||
{ | ||
await Properties_DeviceReceivePropertyUpdateRecoveryAsync( | ||
Client.TransportType.Mqtt_WebSocket_Only, | ||
FaultInjection.FaultType_GracefulShutdownMqtt, | ||
FaultInjection.FaultCloseReason_Bye, | ||
FaultInjection.DefaultFaultDelay) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
private async Task Properties_DeviceUpdateClientPropertiesRecoveryAsync( | ||
Client.TransportType transport, | ||
string faultType, | ||
string reason, | ||
TimeSpan delayInSec, | ||
string proxyAddress = null) | ||
{ | ||
static async Task TestOperationAsync(DeviceClient deviceClient, TestDevice testDevice) | ||
{ | ||
string propName = Guid.NewGuid().ToString(); | ||
string propValue = Guid.NewGuid().ToString(); | ||
|
||
var properties = new ClientPropertyCollection(); | ||
properties.AddRootProperty(propName, propValue); | ||
|
||
await deviceClient.UpdateClientPropertiesAsync(properties).ConfigureAwait(false); | ||
|
||
ClientProperties clientProperties = await deviceClient.GetClientPropertiesAsync().ConfigureAwait(false); | ||
clientProperties.Should().NotBeNull(); | ||
|
||
bool isPropertyPresent = clientProperties.TryGetValue(propName, out string propFromCollection); | ||
isPropertyPresent.Should().BeTrue(); | ||
propFromCollection.Should().Be(propValue); | ||
} | ||
|
||
await FaultInjection | ||
.TestErrorInjectionAsync( | ||
s_devicePrefix, | ||
TestDeviceType.Sasl, | ||
transport, | ||
proxyAddress, | ||
faultType, | ||
reason, | ||
delayInSec, | ||
FaultInjection.DefaultFaultDuration, | ||
(d, t) => { return Task.FromResult(false); }, | ||
TestOperationAsync, | ||
() => { return Task.FromResult(false); }, | ||
Logger) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
private async Task RegistryManagerUpdateDesiredPropertyAsync(string deviceId, string propName, string propValue) | ||
{ | ||
using var registryManager = RegistryManager.CreateFromConnectionString(Configuration.IoTHub.ConnectionString); | ||
|
||
var twinPatch = new Twin(); | ||
twinPatch.Properties.Desired[propName] = propValue; | ||
|
||
await registryManager.UpdateTwinAsync(deviceId, twinPatch, "*").ConfigureAwait(false); | ||
await registryManager.CloseAsync().ConfigureAwait(false); | ||
} | ||
|
||
private async Task Properties_DeviceReceivePropertyUpdateRecoveryAsync( | ||
Client.TransportType transport, | ||
string faultType, | ||
string reason, | ||
TimeSpan delayInSec, | ||
string proxyAddress = null) | ||
{ | ||
TestDeviceCallbackHandler testDeviceCallbackHandler = null; | ||
using var cts = new CancellationTokenSource(FaultInjection.RecoveryTime); | ||
|
||
string propName = Guid.NewGuid().ToString(); | ||
|
||
// Configure the callback and start accepting property update notifications. | ||
async Task InitOperationAsync(DeviceClient deviceClient, TestDevice testDevice) | ||
{ | ||
testDeviceCallbackHandler = new TestDeviceCallbackHandler(deviceClient, testDevice, Logger); | ||
await testDeviceCallbackHandler.SetClientPropertyUpdateCallbackHandlerAsync<string>(propName).ConfigureAwait(false); | ||
} | ||
|
||
// Change the properties from the service side and verify the device received it. | ||
async Task TestOperationAsync(DeviceClient deviceClient, TestDevice testDevice) | ||
{ | ||
string propValue = Guid.NewGuid().ToString(); | ||
testDeviceCallbackHandler.ExpectedClientPropertyValue = propValue; | ||
|
||
Logger.Trace($"{nameof(Properties_DeviceReceivePropertyUpdateRecoveryAsync)}: name={propName}, value={propValue}"); | ||
|
||
await Task | ||
.WhenAll( | ||
RegistryManagerUpdateDesiredPropertyAsync(testDevice.Id, propName, propValue), | ||
testDeviceCallbackHandler.WaitForClientPropertyUpdateCallbcakAsync(cts.Token)) | ||
.ConfigureAwait(false); | ||
} | ||
|
||
// Cleanup references. | ||
Task CleanupOperationAsync() | ||
{ | ||
testDeviceCallbackHandler?.Dispose(); | ||
return Task.FromResult(false); | ||
} | ||
|
||
await FaultInjection | ||
.TestErrorInjectionAsync( | ||
s_devicePrefix, | ||
TestDeviceType.Sasl, | ||
transport, | ||
proxyAddress, | ||
faultType, | ||
reason, | ||
delayInSec, | ||
FaultInjection.DefaultFaultDuration, | ||
InitOperationAsync, | ||
TestOperationAsync, | ||
CleanupOperationAsync, | ||
Logger) | ||
.ConfigureAwait(false); | ||
} | ||
} | ||
} |