You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This commit was created on GitHub.com and signed with GitHub’s verified signature.
The key has expired.
Allow State variable set check_init=False to skip
initialization test. One use case is for integrators
with non-zero inputs (such as state-of-charge integration).
Solves power flow for systems with multiple areas, each with
one Slack generator.
Added Jumper for connecting two buses with zero impedance.
REGCA1 and synchronous generators can take power ratio
parameters gammap and gammaq.
New models: IEESGO and IEEET1, EXAC4.
Refactored exciters, turbine governors, and renewable models
into modules.