Homebridge plugin for SIEMENS Step7 and compatible PLCs
Note
- Now compatible with the beta version of Homebridge 2.0.0
- Now compatible with Node.js v22 and the latest Docker images of Homebridge
SIEMENS S7 PLC plugin for Homebridge
- This plugin uses snap7 via node-snap7, making it compatible with the following PLCs:
- S7 300
- S7 400
- S7 1200 (see Snap7 notes)
- S7 1500 (see Snap7 notes)
- Compatible PLCs such as YASKAWA / VIPA:
- SLIO e.g.
- 013-CCF0R00
- 014-CEF0R01
- 015-CEFNR00
- 015-CEFPR01
- 017-CEFPR00
- MICRO PLC
- 300S+
- SLIO e.g.
- The plugin uses PG-Communication (programming device communication) to connect to the PLC
- Optionally, OP-Communication (HMI or panel communication) can also be used to connect to the PLC
- NOTE: You may need to increase the connection resources for PG-Communication or OP-Communication within Siemens Simatic Manager or Siemens TIA Portal. The default value is 1, which may lead to connection problems when using the programming tool or panel and this plugin simultaneously.
- Tested with S7-300, S7-1200, and S7-300 compatible PLCs from YASKAWA and VIPA
- Implementation is based on the documentation of the Homebridge API
- Supports polling of the PLC from the homebridge-plc plugin with a per-accessory defined interval
- Supports push from the PLC to the homebridge-plc plugin via HTTP PUT/GET
- Supports control of PLC accessories via HTTP PUT/GET
- Supported Accessories:
- LightBulb as
PLC_LightBulb
- Outlet as
PLC_Outlet
- Switch as
PLC_Switch
- Temperature Sensor as
PLC_TemperatureSensor
- Humidity Sensor as
PLC_HumiditySensor
- Thermostat as
PLC_Thermostat
- Humidifier/Dehumidifier as
PLC_HumidifierDehumidifier
- Shutter as
PLC_WindowCovering
- Window as
PLC_Window
- Door as
PLC_Door
- Occupancy Sensor as
PLC_OccupancySensor
- Motion Sensor as
PLC_MotionSensor
- Contact Sensor as
PLC_ContactSensor
- Leak Sensor as
PLC_LeakSensor
- Faucet as
PLC_Faucet
- Valve as
PLC_Valve
- Security System as
PLC_SecuritySystem
- Push button attached to PLC as
PLC_StatelessProgrammableSwitch
- Doorbell push button attached to PLC as
PLC_Doorbell
- Lock mechanism as
PLC_LockMechanism
- Boolean lock mechanism as
PLC_LockMechanismBool
- Garage door as
PLC_GarageDoorOpener
- Smoke Sensor as
PLC_SmokeSensor
- Fan as
PLC_Fan
- Light Sensor as
PLC_LightSensor
- Air Purifier as
PLC_AirPurifier
- Filter Maintenance as
PLC_FilterMaintenance
- CarbonDioxideSensor as
PLC_CarbonDioxideSensor
- CarbonMonoxideSensor as
PLC_CarbonMonoxideSensor
- LightBulb as
-
Basic Installation
- Install this plugin using:
sudo npm install -g homebridge-plc
- Edit
config.json
to add the PLC platform and its accessories. - Run Homebridge
- Install this plugin using:
-
Install via Homebridge UI (recommended)
- Search for
plc
on the plugin screen of Homebridge UI. - Find
homebridge-plc
- Click install.
- Edit configuration
- Search for
The plugin is configured as a single platform by defining a PLC
platform.
Parameters:
ip
: the IPv4 address of the PLCrack
: the rack number of the PLC (typically0
)slot
: the slot number of the PLC (S7 300/400 typically2
, S7 1200/1500 typically1
)communicationOP
: (optional) when set totrue
, OP-Communication is used instead of PG-Communication. Default isfalse
to use PG-Communication.enablePolling
: (optional) when set totrue
, a background task is executed every second to enable polling for the accessories. Default isfalse
.defaultPollInterval
: (optional) default polling interval for all accessories in seconds. Default value is10
seconds.distributePolling
: (optional) when set totrue
, the polling of the accessories does not start at the same time to distribute the PLC load for the queries. Default isfalse
.enablePush
: (optional) when set totrue
, the configuredport
is opened to push updates of values from the PLC to the plugin. Default isfalse
.enableControl
: (optional) when set totrue
, the configuredport
is opened to control accessories by HTTP request. Default isfalse
.port
: (optional) port for HTTP server to handle incoming HTTP requests for push and control functionality. Default port is8888
.- Experimental features
forward
: (optional) there is a limit of a maximum of 149 supported accessories by Homebridge. To overcome this limit, you can create a second instance of Homebridge running homebridge-plc and forward all push and control with no matchingdb
to the other instance. Set the destination address of the second instance e.g.http:\\127.0.0.1:8889
.mirror
: (optional) There are environments where it could make sense to share the same accessories on two Homebridge instances to allow pairing with another Home with Apple Home App or Home Assistant. This option mirrors all values read from the PLC by this instance to a second instance. It also forwards all push requests to the second instance. The optionenablePush
has to be enabled on the second instance. Set the destination address of the second instance e.g.http:\\192.168.1.11:8888
.
- In the platform, you can declare different types of accessories.
- The notation (push support) identifies that the parameter supports direct updates from the PLC.
- The notation (control support) identifies parameters that can be controlled by HTTP request.
Normal light. See also simple PLC example for single bit and separate bits.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_On
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_On
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_On)
- Separate Bits for on/off:
set_On
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Off
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
get_Brightness
: (optional) (push support) get brightness value S7 typeByte
e.g.56
forDB4DBB56
set_Brightness
: (optional but required whenget_Brightness
is defined) (control support) set brightness value S7 typeByte
e.g.57
forDB4DBB57
- Brightness range definitions (optional)
minBrightnessValue
default value: 0maxBrightnessValue
default value: 100minBrightnessStep
default value: 1
Outlet, possible to show also as ventilator or light.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_On
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_On
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_On)
- Separate Bits for on/off:
set_On_Set
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_On_Reset
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
Switch, possible to show also as ventilator or light.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_On
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_On
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_On)
- Separate Bits for on/off:
set_On
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Off
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
Normal temperature sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current Temperature:
get_CurrentTemperature
: (push support) offset to get current temperature S7 typeReal
e.g.55
forDB4DBD55
- Temperature range (optional)
minTemperatureValue
default value: -270maxTemperatureValue
default value: 100minTemperatureStep
default value: 0.1
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Normal humidity sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current Humidity:
get_CurrentRelativeHumidity
: (push support) offset to get current humidity S7 typeReal
e.g.55
forDB4DBD55
- Humidity range (optional)
minHumidityValue
default value: 0maxHumidityValue
default value: 100minHumidityStep
default value: 1
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Temperature/humidity sensor with regulation.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current Temperature:
get_CurrentTemperature
: (push support) offset to get current temperature S7 typeReal
e.g.0
forDB4DBD0
- Temperature range (optional)
minTemperatureValue
default value: -270maxTemperatureValue
default value: 100minTemperatureStep
default value: 0.1
- Target Temperature:
get_TargetTemperature
: (push support) offset to get target temperature S7 typeReal
e.g.4
forDB4DBD4
set_TargetTemperature
: (control support) offset to set target temperature S7 typeReal
e.g.4
forDB4DBD4
(can have the same value as get_TargetTemperature)- Target temperature range definitions (optional)
minTargetTemperatureValue
default value: 10maxTargetTemperatureValue
default value: 38minTargetTemperatureStep
default value: 0.1 Note: lower values may not be supported by Homekit
- Current Humidity:
get_CurrentRelativeHumidity
: (optional) (push support) offset to get current humidity S7 typeReal
e.g.0
forDB4DBD0
- Humidity range (optional)
minHumidityValue
default value: 0maxHumidityValue
default value: 100minHumidityStep
default value: 1
- Target Humidity:
get_TargetRelativeHumidity
: (optional) (push support) offset to get target humidity S7 typeReal
e.g.4
forDB4DBD4
set_TargetRelativeHumidity
: (optional) (control support) offset to set target humidity S7 typeReal
e.g.4
forDB4DBD4
(can have the same value as get_TargetRelativeHumidity)- Target relative humidity range definitions (optional)
minTargetHumidityValue
default value: 0maxTargetHumidityValue
default value: 100minTargetHumidityStep
default value: 1
- Current State:
get_CurrentHeatingCoolingState
: (optional) (push support) offset to get current heating/cooling state S7 typeByte
e.g.8
forDB4DBB8
. When not defined, fixed1
: heating is used.0
: inactive (shown as green in home app)1
: heating (shown as orange in home app)2
: cooling (shown as blue in home app)
mapGetCurrentHeatingCoolingState
: (optional) define mapping array forget_CurrentHeatingCoolingState
. The PLC value is used as an index into the table. e.g.[0, 2]
which maps the PLC value0->0 1->2
when the PLC supports only two states with0:inactive
and1:cooling
.
- Target State:
get_TargetHeatingCoolingState
: (optional) (push support) offset to get target heating/cooling state. S7 typeByte
e.g.9
forDB4DBB9
. When not defined, fixed3
: automatic is used.0
: off1
: heat2
: cool3
: automatic
mapGetTargetHeatingCoolingState
: (optional) define mapping array forget_TargetHeatingCoolingState
. The PLC value is used as an index into the table. e.g.[0, 3]
which maps the PLC value0->0 1->3
when the PLC supports only two states with0:off
and1:automatic
.set_TargetHeatingCoolingState
: (optional) (control support) offset to set target heating/cooling state. Can be identical withget_TargetHeatingCoolingState
. Has to be defined whenget_TargetHeatingCoolingState
is defined. When not defined, writes changes are ignored. S7 typeByte
e.g.9
forDB4DBB9
.0
: off1
: heat2
: cool3
: automatic
mapSetTargetHeatingCoolingState
: (optional) define mapping array forset_TargetHeatingCoolingState
. The home app value is used as an index into the table. e.g.[0, 1, 0, 3]
which maps the PLC value0->0 1->1 2->0, 3->3
when the PLC supports only two states with0:off
and1:heat
and3:automatic
. The state cool is mapped to off.
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Humidifier and/or Dehumidifier.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_CurrentRelativeHumidity
: (push support) offset to get current humidity S7 typeReal
e.g.55
forDB4DBD55
get_Active
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_Active
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_Active)
- Separate Bits for on/off:
set_Active_Set
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Active_Reset
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
- Current State:
get_CurrentHumidifierDehumidifierState
: (optional) (push support) offset to get current state. Default value1:idle
. S7 typeByte
e.g.55
forDB4DBD55
0
: inactive1
: idle2
: humidifying3
: dehumidifying
mapGetCurrentHumidifierDehumidifierState
: (optional) define mapping array forget_CurrentHumidifierDehumidifierState
. The PLC value is used as an index into the table. e.g.[1, 3]
which maps the PLC value0->1 1->3
when the PLC supports only two states with0:idle
and1:dehumidifying
.
- Target State:
default_TargetHumidifierDehumidifierState
: (optional) defines an alternative value that's returned whenget_TargetHumidifierDehumidifierState
is not defined. Default value0:auto
0
: auto (humidifier or dehumidifier)1
: humidifier2
: dehumidifier
get_TargetHumidifierDehumidifierState
: (optional) (push support) offset to get current target state S7 typeByte
e.g.55
forDB4DBD55
0
: auto (humidifier or dehumidifier)1
: humidifier2
: dehumidifier
set_TargetHumidifierDehumidifierState
: (optional) (control support) offset to set current target state. Needs to be defined whenget_TargetHumidifierDehumidifierState
is set. S7 typeByte
e.g.55
forDB4DBD55
0
: auto (humidifier or dehumidifier)1
: humidifier2
: dehumidifier
mapGetTargetHumidifierDehumidifierState
: (optional) define mapping array forget_TargetHumidifierDehumidifierState
. The PLC value is used as an index into the table. e.g.[2,1]
which maps the PLC value0->1 1->2
when the PLC supports only one state with0:dehumidifier 1:humidifier
.mapSetTargetHumidifierDehumidifierState
: (optional) define mapping array forset_TargetHumidifierDehumidifierState
. The home app value is used as an index into the table. e.g.[2, 2, 2]
writes always the value 2 to the PLC regardless of what's set in the home app.
- Rotation Speed:
- Byte:
get_RotationSpeedByte
: (optional) (push support) offset to get rotation speed state S7 typeByte
e.g.8
forDB4DBB8
.set_RotationSpeedByte
: (optional but required whenget_RotationSpeedByte
is defined) (push support) offset to get set speed state. S7 typeByte
e.g.9
forDB4DBB9
.
- Real:
get_RotationSpeed
: (optional) (push support) offset to get rotation speed state S7 typeReal
e.g.8
forDB4DBB8
.set_RotationSpeed
: (optional but required whenget_RotationSpeed
is defined) (push support) offset to get set speed state. S7 typeReal
e.g.9
forDB4DBB9
.
- Byte:
- Swing Mode:
get_SwingMode
: (optional) (push support) offset to get swing mode. S7 typeByte
e.g.8
forDB4DBB8
.0
: swing disabled1
: swing enabled
set_SwingMode
: (optional) (control support) offset to set swing mode. S7 typeByte
e.g.9
forDB4DBB9
.0
: swing disabled1
: swing enabled
- Water Level:
get_WaterLevel
: (optional) (push support) offset to water level S7 typeReal
e.g.8
forDB4DBD8
.
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Motor-driven blinds, windows, and doors. Supports also manually driven blinds, windows, and doors to show just the current position in percent. Note: If your sensor shows only open/close, you may also have a look at PLC_ContactSensor
.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
adaptivePolling
: (optional) when set totrue
, the current position will be polled until the target position is reached. Polling starts with the set target position from the home app. This allows showing the shutter as opening... or closing... in the home app during movement.adaptivePollingInterval
: (optional) poll interval in seconds during high-frequency polling. Default value is1
second.forceCurrentPosition
: (optional) when set totrue
, the position set byset_TargetPosition
is directly used as the current position. By this, it seems in the home app as the target position was directly reached. This is recommended when not usingadaptivePolling
or pushing the value from the PLC.enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current position:
get_CurrentPosition
: (push support) offset to get current position0:closed 100:open
S7 typeByte
e.g.0
forDB4DBB0
0
: closedin between
: partly open100
: open
invertPosition
: (optional) set totrue
to invert the values of current and target position from0:closed 100:open
to100:closed 0:open
mapGetCurrentPosition
: (optional) define mapping array for get position. The PLC value is used as an index into the table. e.g.[0, 25, 100]
which maps the PLC value0->0 1->25 2->100
this is useful e.g. for window open state.
- Target position:
- If one of the (optional) target position settings is specified, all are needed. If not specified, it is not movable and sticks to the current position.
get_TargetPosition
: (optional) (push support) offset to get target position S7 typeByte
e.g.1
forDB4DBB1
(can have the same value as set_TargetPosition)0
: closedin between
: partly open100
: open
set_TargetPosition
: (optional) (control support) offset to set current position0:closed 100:open
S7 typeByte
e.g.2
forDB4DBB2
(can have the same value as get_TargetPosition)0
: closedin between
: partly open100
: open
get_PositionState
: (optional) (push support) offset to current movement state. If not defined, fixed2
is returned. S7 typeByte
e.g.3
forDB4DBB3
0
: down1
: up2
: stop
set_HoldPosition
: (optional) (control support) offset and bit to set to 1 to stop movement. (Seems not to be used by HomeApp) When not defined, writes will be ignored. S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
Presence detection sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
invertOccupancy
: (optional) set totrue
to invert the bit tofalse:presence
andtrue:no-presence
.enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_OccupancyDetected
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
false
: no occupancytrue
: occupancy detected
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Movement detection sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
invertMotionDetected
: (optional) set totrue
to invert the bit tofalse:motion
andtrue:no-motion
.enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_MotionDetected
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
false
: no motiontrue
: motion detected
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Generic contact sensor. The home app allows displaying as window, door, blind/shutter, garage door, or contact sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
invertContactSensorState
: (optional) set totrue
to invert the bit tofalse:closed
andtrue:open
.enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_ContactSensorState
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
false
: closedtrue
: open
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Leak sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
invertLeakDetected
: (optional) set totrue
to invert the bit tofalse:leak detected
andtrue:no leak detected
.enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_LeakDetected
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
false
: no leak detectedtrue
: leak detected
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Watering for the garden.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_Active
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_Active
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_Active)
- Separate Bits for on/off:
set_Active
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Deactivate
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
Valve configurable as generic valve, irrigation, shower head, or water faucet.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.ValveType
: configures the valve type that is returned0
: generic valve1
: irrigation2
: shower head3
: water faucet
get_Active
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_Active
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_Active)
- Separate Bits for on/off:
set_Active
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Deactivate
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
- If one of the (optional) duration settings is specified, all are needed:
get_SetDuration
: (optional) (push support) offset to get duration 0..3600 sec S7 typeTime
e.g.10
forDB4DBD10
set_SetDuration
: (optional) (control support) offset to set duration 0..3600 sec S7 typeTime
e.g.14
forDB4DBD14
get_RemainingDuration
: (optional) (push support) offset to get remaining duration 0..3600 sec S7 typeTime
e.g.18
forDB4DBD18
Alarm system.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state of the security system will be polled.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current State:
get_SecuritySystemCurrentState
: (push support) offset to current security system state S7 typeByte
e.g.3
forDB4DBB3
0
: armed stay at home1
: armed away from home2
: armed night3
: disarmed4
: alarm triggered
mapGetSecuritySystemCurrentState
: (optional) define mapping array for get security system state. The PLC value is used as an index into the table. e.g.[3, 1]
which maps the PLC value0->3 1->2
when the PLC supports only two states with0:disarmed
and1:armed
and2:alarm
.
- Target State:
set_SecuritySystemTargetState
: (control support) offset to set target security system state S7 typeByte
e.g.5
forDB4DBB4
get_SecuritySystemTargetState
: (push support) offset to set target security system state S7 typeByte
e.g.6
forDB4DBB6
0
: armed stay at home1
: armed away from home2
: armed night3
: disarmed
mapSetSecuritySystemTargetState
: (optional) define mapping array for set security system state. The home app value is used as an index into the table. e.g.[1, 1, 1, 0, 2]
which maps the PLC value0->1 1->1 2->1, 3->0, 4->2
when the PLC supports only two states with0:disarmed
and1:armed
and2:alarm
.mapGetSecuritySystemTargetState
: (optional) define mapping array for get security system state. The PLC value is used as an index into the table. e.g.[3, 1]
which maps the PLC value0->3 1->2
when the PLC supports only two states with0:disarmed
and1:armed
and2:alarm
.
Stateless switch from PLC to home app.
Trigger actions in the home app only works with control center e.g. AppleTV or HomePod. Polling or push from PLC required!
Polling mode homebridge-plc polls isEvent
. The PLC sets the bit to true
. homebridge-plc reads get_ProgrammableSwitchEvent
and sets the isEvent
bit to false
.
Push mode PLC informs homebridge-plc by HTTP request with the value for get_ProgrammableSwitchEvent
.
Control External simulates event by HTTP request with the value for get_ProgrammableSwitchEvent
.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.isEvent
: offset and bit that is polled by homebridge-plc. PLC has to set totrue
. Whentrue
, the event is read fromget_ProgrammableSwitchEvent
and set tofalse
by homebridge-plc to confirm that the event is handled. S7 typeBool
e.g.55.1
forDB4DBX55.1
(polling only, not used for push)get_ProgrammableSwitchEvent
: (push support) (control support) offset to read current event of the switch. This is reported towards the home app S7 typeByte
e.g.3
forDB4DBB3
0
: single press1
: double press2
: long press
Lock mechanism.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.forceCurrentLockState
: (optional) when set totrue
, the position set byset_LockTargetState
is directly used as the current state. By this, it seems in the home app as the target state was directly reached. This is recommended when not usingenablePolling
or pushing the value from the PLC.get_LockCurrentState
: (push support) offset to read current state S7 typeByte
e.g.3
forDB4DBB3
0
: unsecured1
: secured2
: jammed3
: unknown
get_LockTargetState
: (push support) offset to read target state S7 typeByte
e.g.3
forDB4DBB3
0
: unsecured1
: secured
set_LockTargetState
: (control support) offset to write target state S7 typeByte
e.g.3
forDB4DBB3
0
: unsecured1
: secured
Lock mechanism implemented as bool on the PLC.
NOTE: The convention 0
=false
: closed/secured 1
=true
: open/unsecured
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.forceCurrentLockState
: (optional) when set totrue
, the state set byset_LockTargetState
is directly used as the current state. By this, it seems in the home app as the target state was directly reached. This is recommended when not usingenablePolling
or pushing the value from the PLC.invertLockState
: (optional) when set totrue
, all states are inverted (current and target state)false
: unsecured andtrue
: secured.get_LockCurrentStateBool
: (push support) offset to read current state S7 typeBool
e.g.3.1
forDB4DBB3
false
: securedtrue
: unsecured
get_LockTargetStateBool
: (push support) offset to read target state S7 typeBool
e.g.3.1
forDB4DBB3
false
: securedtrue
: unsecured
- Single Bit for secure/unsecured:
set_LockTargetStateBool
: (control support) offset to write target state S7 typeBool
e.g.3.1
forDB4DBB3
false
: securedtrue
: unsecured
- Separate Bits for secure/unsecured:
set_LockTargetStateBool_Secured
: (control support) offset and bit to set totrue
when switching to target state secured S7 typeBool
PLC has to set tofalse
e.g.3.3
forDB4DBX55.1
set_LockTargetStateBool_Unsecured
: offset and bit to set totrue
when switching to target state unsecured S7 typeBool
PLC has to set tofalse
e.g.3.4
forDB4DBX55.2
Garage door.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.forceCurrentDoorState
: (optional) when set totrue
, the position set byset_TargetDoorState
is directly used as the current state. By this, it seems in the home app as the target state was directly reached. This is recommended when not usingenablePolling
or pushing the value from the PLC.get_ObstructionDetected
: (optional) (push support) offset and bit for obstruction detection. True means that the door was blocked. S7 typeBool
e.g.55.1
forDB4DBX55.1
get_CurrentDoorState
: (push support) offset to read current state S7 typeByte
e.g.3
forDB4DBB3
0
: open1
: closed2
: opening3
: closing4
: stopped
get_TargetDoorState
: (push support) offset to read target state S7 typeByte
e.g.3
forDB4DBB3
0
: open1
: closed
set_TargetDoorState
: (control support) offset to write target state S7 typeByte
e.g.3
forDB4DBB3
0
: open1
: closed
Fire alarm.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.get_SmokeDetected
: (push support) offset and bit for smoke detection. S7 typeBool
e.g.55.1
forDB4DBX55.1
false
: oktrue
: smoke detected
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Ventilator.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current State:
default_CurrentFanState
: (optional) defines an alternative value that's returned whenget_CurrentFanState
is not defined. Default value0:inactive
get_CurrentFanState
: (optional) (push support) offset to get current heating/cooling state S7 typeByte
e.g.8
forDB4DBB8
.0
: inactive1
: idle2
: blowing
mapCurrentFanStateGet
: (optional) define mapping array forget_CurrentFanState
. The PLC value is used as an index into the table. e.g.[0, 2]
which maps the PLC value0->1 1->2
when the PLC supports only two states with0:idle
and1:blowing
.
- Target State:
default_TargetFanState
: (optional) defines an alternative value that's returned whenget_TargetFanState
is not defined. Default value0:manual
0
: manual1
: automatic
get_TargetFanState
: (optional) (push support) offset to get target heating/cooling state. S7 typeByte
e.g.9
forDB4DBB9
. When not defined, fixed1
: automatic is used.0
: manual1
: automatic
set_TargetFanState
: (optional but required whenget_TargetFanState
is defined) (control support) offset to get target heating/cooling state. S7 typeByte
e.g.9
forDB4DBB9
. When not defined, fixed1
: automatic is used.0
: manual1
: automatic
mapTargetFanStateGet
: (optional) define mapping array forget_TargetFanState
. The PLC value is used as an index into the table. e.g.[1, 0]
which maps the PLC value0->1 1->0
when the PLC supports only two states with0:automatic
and1:manual
.mapTargetFanStateSet
: (optional) define mapping array forset_TargetFanState
. The home app value is used as an index into the table. e.g.[1, 0]
which maps the PLC value0->1 1->0
when the PLC supports only two states with0:automatic
and1:manual
.
- Rotation Direction:
get_RotationDirection
: (optional) (push support) offset to get rotation direction state. S7 typeByte
e.g.9
forDB4DBB9
. When not defined, fixed0
: clockwise is used.0
: clockwise1
: counterclockwise
set_RotationDirection
: (optional) (control support) offset to set rotation direction state. S7 typeByte
e.g.9
forDB4DBB9
.0
: clockwise1
: counterclockwise
mapRotationDirectionGet
: (optional) define mapping array forget_RotationDirection
. The PLC value is used as an index into the table. e.g.[1, 0]
inverts the direction.mapRotationDirectionSet
: (optional) define mapping array forset_RotationDirection
. The home app value is used as an index into the table. e.g.[1, 0]
inverts the direction.
- Rotation Speed:
- Byte:
get_RotationSpeedByte
: (optional) (push support) offset to get rotation speed state S7 typeByte
e.g.8
forDB4DBB8
.set_RotationSpeedByte
: (optional but required whenget_RotationSpeedByte
is defined) (push support) offset to get set speed state. S7 typeByte
e.g.9
forDB4DBB9
.
- Real:
get_RotationSpeed
: (optional) (push support) offset to get rotation speed state S7 typeReal
e.g.8
forDB4DBB8
.set_RotationSpeed
: (optional but required whenget_RotationSpeed
is defined) (push support) offset to get set speed state. S7 typeReal
e.g.9
forDB4DBB9
.
- Byte:
get_Active
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_Active
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_Active)
- Separate Bits for on/off:
set_Active_Set
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Active_Reset
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
Illuminance sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- AmbientLightLevel:
- DInt:
get_CurrentAmbientLightLevelDInt
: (push support) offset to get current illumination in LUX S7 typeDInt
value limited to 0.0001 ~ 100,000 e.g.55
forDB4DBD55
- Real:
get_CurrentAmbientLightLevel
: (push support) offset to get current illumination in LUX S7 typeReal
value limited to 0.0001 ~ 100,000 e.g.55
forDB4DBD55
- DInt:
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Air filter.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Current State:
default_CurrentAirPurifierState
: (optional) defines an alternative value that's returned whenget_CurrentAirPurifierState
is not defined. Default value0:inactive
get_CurrentAirPurifierState
: (optional) (push support) offset to get current heating/cooling state S7 typeByte
e.g.8
forDB4DBB8
.0
: inactive1
: idle2
: purifying air
mapCurrentAirPurifierState
: (optional) define mapping array forget_CurrentAirPurifierState
. The PLC value is used as an index into the table. e.g.[0, 2]
which maps the PLC value0->1 1->2
when the PLC supports only two states with0:inactive
and1:idle
.
- Target State:
default_TargetAirPurifierState
: (optional) defines an alternative value that's returned whenget_TargetAirPurifierState
is not defined. Default value0:manual
0
: manual1
: automatic
get_TargetAirPurifierState
: (optional) (push support) offset to get target heating/cooling state. S7 typeByte
e.g.9
forDB4DBB9
. When not defined, fixed1
: automatic is used.0
: manual1
: automatic
set_TargetAirPurifierState
: (optional but required whenget_TargetAirPurifierState
is defined) (control support) offset to get target heating/cooling state. S7 typeByte
e.g.9
forDB4DBB9
. When not defined, fixed1
: automatic is used.0
: manual1
: automatic
mapTargetAirPurifierStateGet
: (optional) define mapping array forget_TargetAirPurifierState
. The PLC value is used as an index into the table. e.g.[1, 0]
which maps the PLC value0->1 1->0
when the PLC supports only two states with0:automatic
and1:manual
.mapTargetAirPurifierStateSet
: (optional) define mapping array forset_TargetAirPurifierState
. The home app value is used as an index into the table. e.g.[1, 0]
which maps the PLC value0->1 1->0
when the PLC supports only two states with0:automatic
and1:manual
.
- Swing Mode:
get_SwingMode
: (optional) (push support) offset to get swing mode. S7 typeByte
e.g.8
forDB4DBB8
.0
: swing disabled1
: swing enabled
set_SwingMode
: (optional) (control support) offset to set swing mode. S7 typeByte
e.g.9
forDB4DBB9
.0
: swing disabled1
: swing enabled
- Rotation Speed:
- Byte:
get_RotationSpeedByte
: (optional) (push support) offset to get rotation speed state S7 typeByte
e.g.8
forDB4DBB8
.set_RotationSpeedByte
: (optional but required whenget_RotationSpeedByte
is defined) (push support) offset to get set speed state. S7 typeByte
e.g.9
forDB4DBB9
.
- Real:
get_RotationSpeed
: (optional) (push support) offset to get rotation speed state S7 typeReal
e.g.8
forDB4DBB8
.set_RotationSpeed
: (optional but required whenget_RotationSpeed
is defined) (push support) offset to get set speed state. S7 typeReal
e.g.9
forDB4DBB9
.
- Byte:
get_Active
: (push support) offset and bit to get the current status S7 typeBool
e.g.55.0
forDB4DBX55.0
- Single Bit for on/off:
set_Active
: (control support) offset and bit to set on/off S7 typeBool
e.g.55.0
forDB4DBX55.0
(could be the same as get_Active)
- Separate Bits for on/off:
set_Active_Set
: (control support) offset and bit to set on S7 typeBool
PLC has to set to 0 e.g.55.1
forDB4DBX55.1
set_Active_Reset
: offset and bit to set off S7 typeBool
PLC has to set to 0 e.g.55.2
forDB4DBX55.2
- Filter change:
get_FilterChangeIndication
: (push support) offset and bit for filter change indication S7 typeBool
e.g.55.3
forDB4DBX55.3
0
: filter oktrue
: change filter
get_FilterLifeLevel
: (optional) (push support) offset and bit for filter life level S7 typeByte
e.g.56
forDB4DBX56
0
: change filter100
: filter is new
set_ResetFilterIndication
: (optional) (control support) offset and bit for filter change indication S7 typeBool
PLC has to set to 0 after detecting change to true via homebridge e.g.55.4
forDB4DBX55.4
NOTE: Currently not used by HomeApp
Filter change indication (Currently neither supported in HomeApp and HomeBridge).
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Filter change:
get_FilterChangeIndication
: (push support) offset and bit for filter change indication S7 typeBool
e.g.55.3
forDB4DBX55.3
false
: filter oktrue
: change filter
get_FilterLifeLevel
: (optional) (push support) offset and bit for filter life level S7 typeByte
e.g.56
forDB4DBX56
0
: change filter100
: filter is new
set_ResetFilterIndication
: (optional) (control support) offset and bit for filter change indication S7 typeBool
PLC has to set to 0 after detecting change to true via homebridge e.g.55.4
forDB4DBX55.4
NOTE: Currently not used by HomeApp
Carbon Dioxide Sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Detected:
get_CarbonDioxideDetected
: (push support) offset and bit for CO2 detection S7 typeBool
e.g.55.3
forDB4DBX55.3
false
: normal CO2 leveltrue
: abnormal CO2 level
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Carbon Monoxide Sensor.
name
: unique name of the accessorymanufacturer
: (optional) descriptiondb
: S7 data base number e.g.4
forDB4
enablePolling
: (optional) when set totrue
, the current state will be polled. It is mandatory to enable polling mode on the platform level.pollInterval
: (optional) poll interval in seconds. Default value is defined in the platform definition.- Detected:
get_CarbonMonoxideDetected
: (push support) offset and bit for CO detection S7 typeBool
e.g.55.3
forDB4DBX55.3
false
: normal CO leveltrue
: abnormal CO level
get_StatusTampered
: (optional) (push support) offset and bit for tamper detection S7 typeBool
(e.g.,55.2
forDB4DBX55.2
) (Home app shows this only within the options)false
: oktrue
: tampered
get_StatusLowBattery
: (optional) (push support) offset and bit for battery low detection S7 typeBool
(e.g.,55.3
forDB4DBX55.3
) (Home app does not inform with push notification)false
: oktrue
: battery low
Note: The example is just an example. It contains also some optional settings. For testing purposes, all accessories are set to one DB.
{
"bridge": {
"name": "Homebridge DEMO",
"username": "0E:54:47:36:82:26",
"port": 52609,
"pin": "031-55-155"
},
"accessories": [],
"platforms": [
{
"name": "Config",
"port": 8888,
"platform": "config"
},
{
"platform": "PLC",
"ip": "10.10.10.32",
"rack": 0,
"slot": 2,
"communicationOP": false,
"enablePolling": true,
"defaultPollInterval": 15,
"distributePolling": true,
"enablePush": true,
"enableControl": true,
"port": 8888,
"accessories": [
{
"accessory": "PLC_LightBulb",
"name": "LightBulb0",
"manufacturer": "normal light bulb",
"enablePolling": true,
"db": 12,
"get_On": 0.0,
"set_On": 0.1,
"set_Off": 0.2
},
{
"accessory": "PLC_LightBulb",
"name": "LightBulb1",
"manufacturer": "with dim function",
"enablePolling": true,
"db": 12,
"get_On": 2.0,
"set_On": 2.1,
"set_Off": 2.2,
"get_Brightness": 1,
"set_Brightness": 1
},
{
"accessory": "PLC_LightBulb",
"name": "LightBulb2",
"manufacturer": "single bit for on/off",
"enablePolling": true,
"db": 12,
"get_On": 2.3,
"set_On": 2.3
},
{
"accessory": "PLC_Outlet",
"name": "Outlet",
"enablePolling": true,
"db": 12,
"get_On": 2.4,
"set_On": 2.5
},
{
"accessory": "PLC_Switch",
"name": "Switch",
"enablePolling": true,
"db": 12,
"get_On": 2.6,
"set_On": 2.7,
"set_Off": 3.0
},
{
"accessory": "PLC_TemperatureSensor",
"name": "Temperature",
"db": 12,
"get_CurrentTemperature": 4,
"enablePolling": true,
"pollInterval": 60
},
{
"accessory": "PLC_HumiditySensor",
"name": "Humidity",
"db": 12,
"get_CurrentRelativeHumidity": 8,
"enablePolling": true,
"pollInterval": 120
},
{
"accessory": "PLC_Thermostat",
"name": "Thermostat",
"manufacturer": "ground floor",
"db": 12,
"enablePolling": true,
"get_CurrentTemperature": 12,
"get_TargetTemperature": 16,
"set_TargetTemperature": 16,
"get_CurrentHeatingCoolingState": 20,
"mapSetTargetHeatingCoolingState": [
0,
1,
0,
3
]
},
{
"accessory": "PLC_WindowCovering",
"name": "Blind",
"manufacturer": "ground floor",
"db": 12,
"invertPosition": false,
"adaptivePolling": true,
"adaptivePollingInterval": 1,
"enablePolling": true,
"pollInterval": 180,
"get_CurrentPosition": 21,
"get_TargetPosition": 22,
"set_TargetPosition": 1
},
{
"accessory": "PLC_Window",
"name": "Window",
"manufacturer": "ground floor",
"enablePolling": true,
"pollInterval": 60,
"db": 12,
"get_CurrentPosition": 23,
"mapGetCurrentPosition": [
0,
25,
100
]
},
{
"accessory": "PLC_Door",
"name": "Door",
"manufacturer": "ground floor",
"enablePolling": true,
"pollInterval": 10,
"db": 12,
"get_CurrentPosition": 24,
"mapGetCurrentPosition": [
0,
100
]
},
{
"accessory": "PLC_OccupancySensor",
"name": "Presence",
"enablePolling": true,
"db": 12,
"get_OccupancyDetected": 25.0
},
{
"accessory": "PLC_MotionSensor",
"name": "Motion",
"enablePolling": true,
"db": 12,
"get_MotionDetected": 25.1
},
{
"accessory": "PLC_ContactSensor",
"name": "ContactSensor",
"enablePolling": true,
"pollInterval": 5,
"db": 12,
"get_ContactSensorState": 25.2
},
{
"accessory": "PLC_LeakSensor",
"name": "LeakSensor",
"enablePolling": true,
"pollInterval": 5,
"db": 12,
"get_LeakDetected": 25.3
},
{
"accessory": "PLC_Faucet",
"name": "Faucet",
"enablePolling": true,
"db": 12,
"get_Active": 28.0,
"set_Active": 28.0
},
{
"accessory": "PLC_Valve",
"name": "Valve",
"db": 12,
"enablePolling": true,
"ValveType": 2,
"get_Active": 28.1,
"set_Active": 28.1,
"get_SetDuration": 30,
"set_SetDuration": 30,
"get_RemainingDuration": 34
},
{
"accessory": "PLC_SecuritySystem",
"name": "SecuritySystem",
"db": 12,
"enablePolling": true,
"pollInterval": 60,
"get_SecuritySystemCurrentState": 26,
"set_SecuritySystemTargetState": 27,
"get_SecuritySystemTargetState": 27,
"mapGetSecuritySystemCurrentState": [
3,
1,
4
],
"mapGetSecuritySystemTargetState": [
3,
1
],
"mapSetSecuritySystemTargetState": [
1,
1,
1,
0
]
},
{
"accessory": "PLC_StatelessProgrammableSwitch",
"name": "Stateless Switch",
"enablePolling": true,
"pollInterval": 10,
"db": 12,
"isEvent": 29.2,
"get_ProgrammableSwitchEvent": 38
},
{
"accessory": "PLC_Doorbell",
"name": "Doorbell",
"enablePolling": true,
"pollInterval": 10,
"db": 12,
"isEvent": 29.2,
"get_ProgrammableSwitchEvent": 38
},
{
"accessory": "PLC_LockMechanism",
"name": "Lock",
"db": 12,
"enablePolling": true,
"get_LockCurrentState": 39,
"get_LockTargetState": 40,
"set_LockTargetState": 40
},
{
"accessory": "PLC_LockMechanismBool",
"name": "LockBool",
"db": 12,
"enablePolling": true,
"get_LockCurrentState": 41.0,
"get_LockTargetState": 41.1,
"set_LockTargetState": 41.1
},
{
"accessory": "PLC_GarageDoorOpener",
"name": "GarageDoor",
"db": 12,
"enablePolling": true,
"get_ObstructionDetected": 41.2,
"get_CurrentDoorState": 42,
"get_TargetDoorState": 43,
"set_TargetDoorState": 43
},
{
"accessory": "PLC_SmokeSensor",
"name": "SmokeSensor",
"db": 12,
"enablePolling": true,
"get_SmokeDetected": 44.0,
"get_StatusTampered": 44.1,
"get_StatusLowBattery": 44.2
},
{
"accessory": "PLC_Fan",
"name": "Fan",
"manufacturer": "Test",
"db": 12,
"set_Active": 44.3,
"get_Active": 44.3,
"get_RotationDirection": 45,
"set_RotationDirection": 45,
"get_RotationSpeed": 46,
"set_RotationSpeed": 46,
"get_CurrentFanState": 47,
"get_TargetFanState": 48,
"set_TargetFanState": 48,
"enablePolling": true
},
{
"accessory": "PLC_LightSensor",
"name": "LightSensor",
"db": 12,
"enablePolling": true,
"get_CurrentAmbientLightLevel": 50,
"pollInterval": 180
}
]
}
]
}
The current values of the accessories are only updated in the following cases:
- Apple Home App:
- App is closed and opened
- Switch between rooms is done
- Homebridge Devices page is opened
The home app does not regularly poll for updates of values. Only when switching rooms or closing/opening the app, the actual values are requested. This behavior is even the case when an AppleTV or HomePod is configured as a control center.
There are three possible ways to handle this:
- That's ok for you
- You enable the polling mode
- You enable the push mode and instrument your PLC code to send the values
To enable this, you have to set "enablePolling": true;
at the platform level and on each individual accessory with an individual interval in seconds "enablePolling": true, "pollInterval": 10,
Example to poll the contact sensor state every 10 seconds:
{
"platforms": [
{
"platform": "PLC",
"ip": "10.10.10.32",
"rack": 0,
"slot": 2,
"enablePolling": true,
"accessories": [
{
"accessory": "PLC_ContactSensor",
"name": "ContactSensor",
"enablePolling": true,
"pollInterval": 10,
"db": 12,
"get_ContactSensorState": 25.2
}
]
}
]
}
It is possible to send updates of values directly from the PLC to the homebridge-plc plugin. This is especially useful when you want notifications from your home app about open/close of doors or just a faster response e.g. with PLC_StatelessProgrammableSwitch.
To enable this, you have to set "enablePush": true,
at the platform level and optionally the port
.
The push takes place via an HTTP request to the configured port with the keyword "push". In order to avoid additional configurations to be shared between the PLC and the homebridge-plc-Plugin, the interface is kept very simple.
The interface that the PLC has to use consists only of the keyword 'push', the database number 'db', the address within the db 'offset' and the value 'value'. This allows the PLC to create a simple interface to push changed values to the homebridge-plc plugin e.g. I created a FC with just one input of type ANY
to push all kinds of values.
The value is assigned to all matching ('db' and 'offset') get_* accessory configurations. All information is transmitted within the URL and in decimal. Parameters that support push are marked with [push] in the description.
It's also possible to forward all push requests where no matching accessory matches the db
configuration to another instance of homebridge-plc. See parameter forward
.
For example, the push from the PLC is done as 'http://homebridgeIp:8888/?push&db=1014&offset=1&value=3' With the following configuration:
{
"platforms": [
{
"platform": "PLC",
"ip": "10.10.10.32",
"rack": 0,
"slot": 2,
"enablePush": true,
"accessories": [
{
"accessory": "PLC_SecuritySystem",
"name": "AlarmSystem",
"db": 1014,
"get_SecuritySystemCurrentState": 1,
"set_SecuritySystemTargetState": 1,
"get_SecuritySystemTargetState": 1
}
]
}
]
}
The value '3' (disarmed) will be used for both 'get_SecuritySystemCurrentState' as well as 'get_SecuritySystemTargetState'.
The request has to be done as an HTTP PUT
or GET
operation. There will be no logging when doing a PUT
operation while there will be detailed output when doing a GET
operation. This is especially intended for testing with the browser as the browser performs a GET
operation per default.
Example for float values when triggered from the browser:
http://homebridgeIp:8888/?push&db=3&offset=22&value=12.5
Example for bool values when triggered from the browser:
http://homebridgeIp:8888/?push&db=5&offset=5.1&value=1
Example for byte values when triggered from the browser:
http://homebridgeIp:8888/?push&db=2&offset=3&value=255
NOTE: Chrome/Edge does at minimum two requests with different parameters resulting in some error messages. I recommend Talend API Tester - Free Edition
It is also possible to control PLC accessories via HTTP PUT
or GET
operation. This might be useful for integration into other automation systems.
To enable this, you have to set "enableControl": true,
at the platform level and optionally the port
.
NOTE: It is currently not possible to query the current state
The interface that the PLC operates consists only of the keyword 'control', the database number 'db', the address within the db 'offset' and the value 'value'. The value is assigned to the matching ('db' and 'offset') set_* accessory configurations. All configurations that are supported are marked with (control support) in the description.
For accessories with separate on/off configurations e.g. PLC_LightBulb
set_On
/set_Off
the set_On
or PLC_LockMechanismBool
set_Secured
/set_Unsecured
the set_Secured
has to be used. With 1
for on and 0
for off.
All information is transmitted within the URL and in decimal.
It's also possible to forward all control requests where no matching accessory matches the db
configuration to another instance of homebridge-plc. See parameter forward
.
**NOTE: Options like invert*
, mapGet*
and mapSet*
are not affecting the control interface. In example for PLC_Window, the value is 0
: closed and 100
: open regardless if invertPosition
is set or not.
The request has to be done as an HTTP PUT
or GET
operation. There will be no logging when doing a PUT
operation while there will be detailed output when doing a GET
operation. This is especially intended for testing with the browser as the browser performs a GET
operation per default.
Example to switch a light bulb from the browser. Let's say the light bulb has the following config:
"platforms": [ { "platform": "PLC", "ip": "10.10.10.32", "rack": 0, "slot": 2, "enableControl": true, "accessories": [ { "accessory": "PLC_LightBulb", "name": "Light", "db": 6096, "set_On": 1.1, "set_Off": 1.0, "get_On": 0.0 } ] } ]
Use this to switch the light bulb on from the browser:
http://homebridgeIp:8888/?control&db=6096&offset=1.1&value=1
Use this to switch the light bulb off from the browser:
http://homebridgeIp:8888/?control&db=6096&offset=1.1&value=0
NOTE: Chrome/Edge does at minimum two requests with different parameters resulting in some error messages. I recommend Talend API Tester - Free Edition
The easiest way is to open the terminal from Homebridge, delete the index.js
file of this plugin, open nano, and paste in the new content.
Afterward, Homebridge can be restarted.
The delete and open of the index.js file can be done by the following command line.
rm node_modules/homebridge-plc/index.js && nano node_modules/homebridge-plc/index.js
npm publish --access public