Releases: Gozilla01/OpenWebNet2-OpenHab-PRE
Releases · Gozilla01/OpenWebNet2-OpenHab-PRE
v2.5.0.M3.pre12
-
Bug fix
- [FIX #80] thermo: setmode in MANUAL not work
- FIX bug
normalizeWhere
for group command - FIX bug Lib
- Temporary modification to the
message.Lighting
, correction for group command management for differentLighting.Type
- Temporary modification to the
message.Automation
, correction for group command management for differentAutomation.Type
-
New features
- [FIX #12 and #32] Add bus AUX for managing auxiliary controls (WHO = 9)
- [FIX #63] Rollershutter items do not track changes in movement from external commands
- [BREAKING CHANGE] channel
shutter
changed the name toshutterPosition
- New channel
shutterMotion
(0
= stop,1
= up,2
= down)
- [BREAKING CHANGE] channel
- [FIX #69] Updating of article statuses, lighting and automation, with the received AMB-GR-GEN commands.
- [Issue #35] Support for group addresses (WHERE=#n)
- For lighting and automation
- New parameter
addrtype
(1
= Point to Point,2
= Area,3
= Group,4
= General) - See the tables Lighting group addresses and Automation group addresses
- Temporary modification to the
message.Lighting
- Added management for new timed WHAT
- Added management for
bus_motion_detector
- [Issue #79] Add what parameter to lighting for
bus_on_off_switch
andzb_on_off_switch
- Added parameters
what
(defaultwhat
= 0),hour
,minute
andsecond
- Added parameters
- Add bus
bus_motion_detector
for motion decector (movement and lux value detected)- Tested with type
BMSE-3003
,BMSE-1001
and048834
- Request lux value
- Parameter
where
andautomaticToOff
- Channel
switch
stateON
to the movement and after 2 seconds automaticallyOFF
- Channel
value
numeric with detected value lux
- Tested with type
- [FIX #52 and #22] Add bus
bus_command
- Translation Italian
For details see changelog