Notifications
You must be signed in to change notification settings - Fork 13
Transports
A transport is configured by creating a configuration section, starting with "transport."
[transport.0]
{transport config here}
or
[transport.growatt]
{transport config here}
the section header is dual purpose and acts as naming mechanism for parameters like "bridge"
Transports using ambigious open ended protocols, such as ModBus, Canbus, or register / address based protocols require a map to be defined. this is done so in the /protocols/ folder through csv tables.
protocol = v0.14
see Protocol Wiki for more on this.
Other transport protocols such as MQTT, do not require this configuration, as the variable names are provided during transmision and therefore do not need interpretation.
Some transports are Event based, such as MQTT, while others are require active reading. for protocols that require active reading such as ModBus, the scan interval is set via "read_interval"
read_interval = 10
For ambigious sensitive protocols/transports such as ModBus, a safety mechanism is in place to help prevent "bricking" your devices or causing potentially catostrophic damages.
In order to write, the configuration csv file must be at least 90% verifiable. Alternatively a manual verification method will be implemented in the future. This mainly entails that the current values in the writeable register ( probably holding ), be within the value range specified in the csv.
Finally, to enable writing for a transport:
write_enabled = true
Finally, to write, "read" data on any bridged transport. In most cases this will likely be MQTT.
custom transports can be created by naming them name.custom and creating the appropriate .py file. for example a custom mqtt transport: copy classes/transports/mqtt.py to classes/transports/mqtt.custom.py
to use this custom transport:
transport=mqtt.custom
naming your transport with .custom will ensure that it won't be overwritten when updating.
These are parameters that apply to all transports
transport =
device_name =
manufacturer =
model =
serial_number =
bridge =
write_enabled = False
Interval = 10
Error_Interval = 60
Transport is the type or method of reading and writing data
transport = modbus_rtu
device_name is used as an identifier and is passed on where applicable. if left blank, device_name will be set to manufacturer + model
device_name = My Solar Inverter 1
manufacturer is used as an identifier and is passed on where applicable.
manufacturer = Growatt
model is used as an identifier and is passed on where applicable.
model = SPF 12000T
serial_number is used as an identifier and is passed on where applicable. If left empty, serial number may be automatically fetched if protocol supports it.
serial_number =
bridge determines which transports to translate data to this value can be a csv to specify multiple transports if bridge is set to "broadcast", data will be broadcasted / sent over all configured transports
bridge = transport.mqtt
write_enabled allows writting to this transport if enabled. many protocols have this disabled by default and require accurate registry maps to enable writing, as misconfiguration can have fatal unintended consequences. by default mqtt allows writing.
write_enabled = True
#Interval Interval ( seconds ), sets the frequency of how often data is actively read from a transport. If interval is not set, data is only sent passively as events occur.
Interval = 10
###required
Transport = MQTT
Host
Port
User
Pass
Base_Topic =
discovery_enabled = True
discovery_topic = homeassistant
###optional
Json = False
Error_Topic = /error
holding_register_prefix =
input_register_prefix =
mqtt "reads" data via the "write" topic. data that is "read" on the mqtt transport is "written" on any bridged transports. i know... confusing :P
during the initialization process, MQTT subscribes to "write enabled" variables / topics, based on the bridged transport's protocol. the writable topics are given a prefix of "/write/"
{base topic}/write/{variable name}
by default mqtt writes data from the bridged transport.
###required
transport = modbus_rtu
protocol_version =
Port =
BaudRate =
Address =
Port is the path to the communications port. on Windows this would be COM#, for Linux /dev/ttyUSB#
these port numbers can change upon restarting, therefore alternatively, the port can be specified via hardware ids (v1.1.2+):
port = [0x1a86:0x7523::1-4]
The hardware ids format is:
[vendor id:product id:serial number:location]
for convience the hardware ids are outputted during script startup.
Serial Port : COM11 = [0x1a86:0x7523::1-4]
needs a lot of work. on the todo to improve. low priority
analyze_protocol = true
when this mode runs, it attempt to read all of the registers of your inverter and attempt to determine which protocol best fits. the higher the value, the more likely that the protocol matches.
=== growatt_2020_v1.24 - 710 ===
input register : 405 of 695
holding register : 305 of 561
=== sigineer_v0.11 - 62 ===
input register : 31 of 150
holding register : 31 of 63
=== v0.14 - 60 ===
input register : 19 of 63
holding register : 41 of 101
the results above suggests that "growatt_2020_v1.24" is the most likely protocol for the inverter.
analyze_protocol = true
analyze_protocol_save_load = true
When enabled, the analyzer will save dump files containing the raw data found while scanning