# Load Cells | ||
|
||
This document describes Klipper's support for load cells. Basic load cell | ||
functionality can be used to read force data and to weigh things like filament. | ||
A calibrated force sensor is an important part of a load cell based probe. | ||
|
||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. not knowing what a load cell does/means for a 3d printer, could you add a sentence or two describing it's usage/benefits for 3d printers/klipper? There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I made some updates to the documentation including a little bit more exposition at the top and a section about how to read the load cell gram force |
||
## Related Documentation | ||
|
||
* [load_cell Config Reference](Config_Reference.md#load_cell) | ||
* [load_cell G-Code Commands](G-Codes.md#load_cell) | ||
* [load_cell Status Reference](Status_Reference.md#load_cell) | ||
|
||
## Using `LOAD_CELL_DIAGNOSTIC` | ||
|
||
When you first connect a load cell its good practice to check for issues by | ||
running `LOAD_CELL_DIAGNOSTIC`. This tool collects 10 seconds of data from the | ||
load cell and resport statistics: | ||
|
||
``` | ||
$ LOAD_CELL_DIAGNOSTIC | ||
// Collecting load cell data for 10 seconds... | ||
// Samples Collected: 3211 | ||
// Measured samples per second: 332.0 | ||
// Good samples: 3211, Saturated samples: 0, Unique values: 900 | ||
// Sample range: [4.01% to 4.02%] | ||
// Sample range / sensor capacity: 0.00524% | ||
``` | ||
|
||
Things you can check with this data: | ||
* The configured sample rate of the sensor should be close to the 'Measured | ||
samples per second' value. If it is not you may have a configuration or wiring | ||
issue. | ||
* 'Saturated samples' should be 0. If you have saturated samples it means the | ||
load sell is seeing more force than it can measure. | ||
* 'Unique values' should be a large percentage of the 'Samples | ||
Collected' value. If 'Unique values' is 1 it is very likely a wiring issue. | ||
* Tap or push on the sensor while `LOAD_CELL_DIAGNOSTIC` runs. If | ||
things are working correctly ths should increase the 'Sample range'. | ||
|
||
## Calibrating a Load Cell | ||
|
||
Load cells are calibrated using the `CALIBRATE_LOAD_CELL` command. This is an | ||
interactive calibration utility that walks you though a 3 step process: | ||
1. First use the `TARE` command to establish the zero force value. This is the | ||
`reference_tare_counts` config value. | ||
2. Next you apply a known load or force to the load cell and run the | ||
`CALIBRATE GRAMS=nnn` command. From this the `counts_per_gram` value is | ||
calculated. See [the next section](#applying-a-known-force-or-load) for some | ||
suggestions on how to do this. | ||
3. Finally, use the `ACCEPT` command to save the results. | ||
|
||
You can cancel the calibration process at any time with `ABORT`. | ||
|
||
### Applying a Known Force or Load | ||
|
||
The `CALIBRATE GRAMS=nnn` step can be accomplished in a number of ways. If your | ||
load cell is under a platform like a bed or filament holder it might be easiest | ||
to put a known mass on the platform. E.g. you could use a couple of 1KG filament | ||
spools. | ||
|
||
If your load cell is in the printer's toolhead a different approach is easier. | ||
Put a digital scale on the printers bed and gently lower the toolhead onto the | ||
scale (or raise the bed into the toolhead if your bed moves). You may be able to | ||
do this using the `FORCE_MOVE` command. But more likely you will have to | ||
manually moving the z axis with the motors off until the toolhead presses on the | ||
scale. | ||
|
||
A good calibration force would ideally be a large percentage of the load cell's | ||
rated capacity. E.g. if you have a 5Kg load cell you would ideally calibrate it | ||
with a 5kg mass. This might work well with under-bed sensors that have to | ||
support a lot of weight. For toolhead probes this may not be a load that your | ||
printer bed or toolhead can tolerate without damage. Do try to use at least 1Kg | ||
of force, most printers should tolerate this without issue. | ||
|
||
When calibrating make careful note of the values reported: | ||
``` | ||
$ CALIBRATE GRAMS=555 | ||
// Calibration value: -2.78% (-59803108), Counts/gram: 73039.78739, | ||
Total capacity: +/- 29.14Kg | ||
``` | ||
The `Total capacity` should be close to the rating of the load cell itself. If | ||
it is much larger you could have used a higher gain setting in the sensor or a | ||
more sensitive load cell. This isn't as critical for 32bit and 24bit sensors but | ||
is much more critical for low bit width sensors. | ||
|
||
## Reading Force Data | ||
Force data can be read with a GCode command: | ||
|
||
``` | ||
READ_LOAD_CELL | ||
// 10.6g (1.94%) | ||
``` | ||
|
||
Data is also continuously read and can be consumed from the load_cell printer | ||
object in a macro: | ||
|
||
``` | ||
{% set grams = printer.load_cell.force_g %} | ||
``` | ||
|
||
This provides an average force over the last 1 second, similar to how | ||
temperature sensors work. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Consider adding a note that weighing things is only possible on printers with the load cells in the bed, and not those with the cell in the extruder.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I don't want to get into applications because there are many. You don't even have to put it in the printer! Several people want to use this functionality to weigh filament spools mounted outside the printer. E.g. https://klipper.discourse.group/t/filament-spool-scale-hx711/19800/
In the future this may be in an application that is just a dry box and not even a printer.
One community member is even working on runout detection in a resin printer.