Exception while calling fromZigbee converter: 'energy_calibration' is not a number, got string ()} #18169

Closed
Nardol opened this issue Jul 1, 2023 · 46 comments
Labels
problem Something isn't working stale Stale issues

Comments

@Nardol
Copy link

Nardol commented Jul 1, 2023

What happened?

Since version 1.32.0 I have errors about "Exception while calling fromZigbee converter: 'energy_calibration' is not a number, got string ()}"

What did you expect to happen?

I did not have these error before

How to reproduce it (minimal and precise)

I did not something else than starting Zigbee2MQTT after I updated it.

Zigbee2MQTT version

1.32.0

Adapter firmware version

20230507

Adapter

Sonoff dongle 2652P not ezsp

Debug log

debug 01/07/2023 14:48:51: Received Zigbee message from 'prise_entree', type 'attributeReport', cluster 'genBasic', data '{"65506":54,"65508":0,"appVersion":192}' from endpoint 1 with groupID 0
debug 01/07/2023 14:49:04: Received Zigbee message from 'prise_meuble_bureau', type 'attributeReport', cluster 'genBasic', data '{"65506":54,"65508":0,"appVersion":192}' from endpoint 1 with groupID 0
debug 01/07/2023 14:49:37: Received Zigbee message from 'prise_meuble_bureau', type 'readResponse', cluster 'seMetering', data '{"currentSummDelivered":[0,1]}' from endpoint 1 with groupID 0
info 01/07/2023 14:49:37: MQTT publish: topic 'zigbee2mqtt/prise_meuble_bureau', payload '{"child_lock":"UNLOCK","current":0,"elapsed":60079,"energy":0.01,"indicator_mode":"off/on","last_seen":"2023-05-21T16:39:03+02:00","linkquality":58,"power":0,"power_outage_memory":"restore","state":"ON","update":{"installed_version":192,"latest_version":192,"state":"idle"},"update_available":null,"voltage":240}'
debug 01/07/2023 14:49:37: Received Zigbee message from 'prise_entree', type 'readResponse', cluster 'seMetering', data '{"currentSummDelivered":[0,39]}' from endpoint 1 with groupID 0
error 01/07/2023 14:49:37: Exception while calling fromZigbee converter: 'energy_calibration' is not a number, got string ()}
debug 01/07/2023 14:49:37: Error: 'energy_calibration' is not a number, got string ()
at assertNumber (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:502:42)
at calibrateAndPrecisionRoundOptions (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:90:5)
at Object.convert (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/converters/fromZigbee.js:768:34)
at Receive.onDeviceMessage (/opt/zigbee2mqtt/lib/extension/receive.ts:150:51)
at EventEmitter.emit (node:events:525:35)
at EventBus.emitDeviceMessage (/opt/zigbee2mqtt/lib/eventBus.ts:102:22)
at Controller. (/opt/zigbee2mqtt/lib/zigbee.ts:106:27)
at Controller.emit (node:events:513:28)
at Controller.selfAndDeviceEmit (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14)
at Controller.onZclOrRawData (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:726:18)
debug 01/07/2023 14:49:37: Received Zigbee message from 'Prise Salle de Bain', type 'readResponse', cluster 'haElectricalMeasurement', data '{"activePower":1,"rmsCurrent":12,"rmsVoltage":238}' from endpoint 1 with groupID 0
info 01/07/2023 14:49:37: MQTT publish: topic 'zigbee2mqtt/Prise Salle de Bain', payload '{"current":0.01,"elapsed":60086,"energy":30.27,"indicator_mode":"off/on","last_seen":"2023-05-21T16:38:27+02:00","linkquality":80,"power":1,"power_outage_memory":"restore","state":"ON","voltage":238}'
debug 01/07/2023 14:49:38: Received Zigbee message from 'Prise Masque Ingrid', type 'attributeReport', cluster 'genBasic', data '{"65506":30,"appVersion":66}' from endpoint 1 with groupID 0
debug 01/07/2023 14:49:46: Received Zigbee message from 'Prise Salle de Bain', type 'attributeReport', cluster 'seMetering', data '{"currentSummDelivered":[0,3027]}' from endpoint 1 with groupID 0
info 01/07/2023 14:49:46: MQTT publish: topic 'zigbee2mqtt/Prise Salle de Bain', payload '{"current":0.01,"elapsed":8026,"energy":30.27,"indicator_mode":"off/on","last_seen":"2023-05-21T16:38:27+02:00","linkquality":76,"power":1,"power_outage_memory":"restore","state":"ON","voltage":238}'
debug 01/07/2023 14:50:05: Received Zigbee message from 'prise_entree', type 'read', cluster 'genTime', data '["localTime"]' from endpoint 1 with groupID 0
debug 01/07/2023 14:50:12: Received Zigbee message from 'prise_entree', type 'attributeReport', cluster 'haElectricalMeasurement', data '{"activePower":0,"rmsCurrent":0,"rmsVoltage":237}' from endpoint 1 with groupID 0
error 01/07/2023 14:50:12: Exception while calling fromZigbee converter: 'power_calibration' is not a number, got string ()}
debug 01/07/2023 14:50:12: Error: 'power_calibration' is not a number, got string ()
at assertNumber (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:502:42)
at calibrateAndPrecisionRoundOptions (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:90:5)
at Object.convert (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/converters/fromZigbee.js:830:41)
at Receive.onDeviceMessage (/opt/zigbee2mqtt/lib/extension/receive.ts:150:51)
at EventEmitter.emit (node:events:525:35)
at EventBus.emitDeviceMessage (/opt/zigbee2mqtt/lib/eventBus.ts:102:22)
at Controller. (/opt/zigbee2mqtt/lib/zigbee.ts:106:27)
at Controller.emit (node:events:513:28)
at Controller.selfAndDeviceEmit (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14)
at Controller.onZclOrRawData (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:726:18)
debug 01/07/2023 14:50:12: Received Zigbee message from 'prise_entree', type 'attributeReport', cluster 'seMetering', data '{"currentSummDelivered":[0,39]}' from endpoint 1 with groupID 0
error 01/07/2023 14:50:12: Exception while calling fromZigbee converter: 'energy_calibration' is not a number, got string ()}
debug 01/07/2023 14:50:12: Error: 'energy_calibration' is not a number, got string ()
at assertNumber (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:502:42)
at calibrateAndPrecisionRoundOptions (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:90:5)
at Object.convert (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/converters/fromZigbee.js:768:34)
at Receive.onDeviceMessage (/opt/zigbee2mqtt/lib/extension/receive.ts:150:51)
at EventEmitter.emit (node:events:525:35)
at EventBus.emitDeviceMessage (/opt/zigbee2mqtt/lib/eventBus.ts:102:22)
at Controller. (/opt/zigbee2mqtt/lib/zigbee.ts:106:27)
at Controller.emit (node:events:513:28)
at Controller.selfAndDeviceEmit (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14)
at Controller.onZclOrRawData (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:726:18)
debug 01/07/2023 14:50:35: Saving state to file /home/homeassistant/config/zigbee2mqtt/state.json
debug 01/07/2023 14:50:37: Received Zigbee message from 'Prise Bureau', type 'readResponse', cluster 'genBasic', data '{"zclVersion":3}' from endpoint 1 with groupID 0
debug 01/07/2023 14:50:37: Successfully pinged 'Prise Bureau' (attempt 1/2)
debug 01/07/2023 14:50:37: Received Zigbee message from 'prise_meuble_bureau', type 'readResponse', cluster 'seMetering', data '{"currentSummDelivered":[0,1]}' from endpoint 1 with groupID 0
info 01/07/2023 14:50:38: MQTT publish: topic 'zigbee2mqtt/prise_meuble_bureau', payload '{"child_lock":"UNLOCK","current":0,"elapsed":60108,"energy":0.01,"indicator_mode":"off/on","last_seen":"2023-05-21T16:39:03+02:00","linkquality":51,"power":0,"power_outage_memory":"restore","state":"ON","update":{"installed_version":192,"latest_version":192,"state":"idle"},"update_available":null,"voltage":240}'
debug 01/07/2023 14:50:38: Received Zigbee message from 'prise_entree', type 'readResponse', cluster 'seMetering', data '{"currentSummDelivered":[0,39]}' from endpoint 1 with groupID 0
error 01/07/2023 14:50:38: Exception while calling fromZigbee converter: 'energy_calibration' is not a number, got string ()}
debug 01/07/2023 14:50:38: Error: 'energy_calibration' is not a number, got string ()
at assertNumber (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:502:42)
at calibrateAndPrecisionRoundOptions (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:90:5)
at Object.convert (/opt/zigbee2mqtt/node_modules/zigbee-herdsman-converters/src/converters/fromZigbee.js:768:34)
at Receive.onDeviceMessage (/opt/zigbee2mqtt/lib/extension/receive.ts:150:51)
at EventEmitter.emit (node:events:525:35)
at EventBus.emitDeviceMessage (/opt/zigbee2mqtt/lib/eventBus.ts:102:22)
at Controller. (/opt/zigbee2mqtt/lib/zigbee.ts:106:27)
at Controller.emit (node:events:513:28)
at Controller.selfAndDeviceEmit (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14)
at Controller.onZclOrRawData (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/controller/controller.ts:726:18)
debug 01/07/2023 14:50:38: Received Zigbee message from 'Prise Salle de Bain', type 'readResponse', cluster 'haElectricalMeasurement', data '{"activePower":1,"rmsCurrent":12,"rmsVoltage":238}' from endpoint 1 with groupID 0
info 01/07/2023 14:50:38: MQTT publish: topic 'zigbee2mqtt/Prise Salle de Bain', payload '{"current":0.01,"elapsed":52123,"energy":30.27,"indicator_mode":"off/on","last_seen":"2023-05-21T16:38:27+02:00","linkquality":80,"power":1,"power_outage_memory":"restore","state":"ON","voltage":238}'
debug 01/07/2023 14:50:40: Received Zigbee message from 'Prise Chambre d'Amis', type 'readResponse', cluster 'genBasic', data '{"zclVersion":3}' from endpoint 1 with groupID 0
debug 01/07/2023 14:50:40: Successfully pinged 'Prise Chambre d'Amis' (attempt 1/2)
debug 01/07/2023 14:50:42: Received Zigbee message from 'Spot Canapé', type 'readResponse', cluster 'genBasic', data '{"zclVersion":8}' from endpoint 11 with groupID 0
debug 01/07/2023 14:50:42: Successfully pinged 'Spot Canapé' (attempt 1/2)
debug 01/07/2023 14:51:00: Received Zigbee message from 'prise_meuble_bureau', type 'attributeReport', cluster 'haElectricalMeasurement', data '{"activePower":0,"rmsCurrent":0,"rmsVoltage":239}' from endpoint 1 with groupID 0
info 01/07/2023 14:51:00: MQTT publish: topic 'zigbee2mqtt/prise_meuble_bureau', payload '{"child_lock":"UNLOCK","current":0,"elapsed":22245,"energy":0.01,"indicator_mode":"off/on","last_seen":"2023-05-21T16:39:03+02:00","linkquality":43,"power":0,"power_outage_memory":"restore","state":"ON","update":{"installed_version":192,"latest_version":192,"state":"idle"},"update_available":null,"voltage":239}'
debug 01/07/2023 14:51:00: Received Zigbee message from 'prise_meuble_bureau', type 'attributeReport', cluster 'seMetering', data '{"currentSummDelivered":[0,1]}' from endpoint 1 with groupID 0
info 01/07/2023 14:51:00: MQTT publish: topic 'zigbee2mqtt/prise_meuble_bureau', payload '{"child_lock":"UNLOCK","current":0,"elapsed":84,"energy":0.01,"indicator_mode":"off/on","last_seen":"2023-05-21T16:39:03+02:00","linkquality":54,"power":0,"power_outage_memory":"restore","state":"ON","update":{"installed_version":192,"latest_version":192,"state":"idle"},"update_available":null,"voltage":239}'

@Nardol Nardol added the problem Something isn't working label Jul 1, 2023
@keithskillicorn
Copy link

I also have the same issue, after upgrading. Every message from Develco Electricity meter is creating an error:

Error 2023-07-01 15:26:58Exception while calling fromZigbee converter: 'power_calibration' is not a number, got string ()}
Debug 2023-07-01 15:26:58Error: 'power_calibration' is not a number, got string () at assertNumber (/app/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:502:42) at calibrateAndPrecisionRoundOptions (/app/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:90:5) at Object.convert (/app/node_modules/zigbee-herdsman-converters/src/converters/fromZigbee.js:752:33) at Object.convert (/app/node_modules/zigbee-herdsman-converters/src/devices/develco.ts:83:40) at Receive.onDeviceMessage (/app/lib/extension/receive.ts:150:51) at EventEmitter.emit (node:events:525:35) at EventBus.emitDeviceMessage (/app/lib/eventBus.ts:102:22) at Controller. (/app/lib/zigbee.ts:106:27) at Controller.emit (node:events:513:28) at Controller.selfAndDeviceEmit (/app/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14)
Info 2023-07-01 15:26:58MQTT publish: topic 'zigbee2mqtt/Develco Electricity Meter', payload '{"battery_low":false,"check_meter":false,"current_summation":0,"energy":1202.191,"interface_mode":"electricity","linkquality":72,"power":309,"pulse_configuration":1000}'

@zzz676
Copy link

zzz676 commented Jul 1, 2023

In the same way, it constantly writes such an error.

Zigbee2MQTT:error 2023-07-01 19:15:08: Exception while calling fromZigbee converter: 'power_calibration' is not a number, got string ()}
Zigbee2MQTT:error 2023-07-01 19:15:38: Exception while calling fromZigbee converter: 'power_calibration' is not a number, got string ()}

@Coldness00
Copy link

I had to downgrade, as I had same issue to control my IKEA ICPSHC24-10EU-IL-1.

@zzz676
Copy link

zzz676 commented Jul 1, 2023

I had to downgrade, as I had same issue to control my IKEA ICPSHC24-10EU-IL-1.

How did you downgrade?

@hellcry37
Copy link

same for me, the problem is i can not downgrade so easily since is not a docker container

@Emilef22
Copy link

Emilef22 commented Jul 1, 2023

same here

@alray31
Copy link

alray31 commented Jul 1, 2023

Same:
image

@lior532
Copy link

lior532 commented Jul 2, 2023

i have the same issue i like to find a solution for this

@Koenkk
Copy link
Owner

Koenkk commented Jul 2, 2023

Make sure in your zigbee2mqtt configuration that e.g. energy_calibration is a number not string.

@zzz676
Copy link

zzz676 commented Jul 2, 2023

Make sure in your zigbee2mqtt configuration that e.g. energy_calibration is a number not string.

I have a repeated error about power_calibration. The error appeared immediately after updating to 1.32, there were no errors on the previous version. no new devices connected.

@zzz676
Copy link

zzz676 commented Jul 2, 2023

Screenshot_2023-07-02-11-12-49-32_c3a231c25ed346e59462e84656a70e50

@NecoPastor
Copy link

I got rid of the error by removing the power_calibration: '' line from the zigbee2mqtt config

@JackTalisker
Copy link

I had the same error with a smartplug.

I choose a 0 for the field of power_calibration in the device "Settings (specific)" page and the error seems to be gone

@Nardol
Copy link
Author

Nardol commented Jul 2, 2023

Thanks, I also had a power_calibration: '' line in my config, error is gone after removing it.
I also remove all other lines I found with value '' to be sure, for other devices I did not have these and now all looks good.

I don't know why I did not have this error before but it is now fixed.

@alray31
Copy link

alray31 commented Jul 2, 2023

Make sure in your zigbee2mqtt configuration that e.g. energy_calibration is a number not string.

I just realized that if you go to the device setting (specific) page of z2m and touch a field when scrolling with a touch screen i.e power_calibration, Z2m will add automatically a line on your configuration. yaml with no value:

yaml before
Screenshot_20230702-082711_Home Assistant

Scrolling and touching the power_calibtation field by mistake:
Screenshot_20230702-082755_Home Assistant

Result:
Screenshot_20230702-082829_Home Assistant

Is there a way to avoid that apart from not using a touchscreen?

@Nardol
Copy link
Author

Nardol commented Jul 2, 2023

Maybe in fact this issue should be opened against ZB2MQTT frontend?

@hellcry37
Copy link

hellcry37 commented Jul 2, 2023

I found the issue, had in my device config some temperature_calibration: '' so basically a null or empty string, after removing them all it was OK.

The problem is, I did not put them there, it was the UI who did when i saved some confs for that sensor. Since i did not put anything there, UI decided to put temperature_calibration: ''

@vadne
Copy link

vadne commented Jul 2, 2023

I have the same trouble... While I'm waiting for the fix, I rolled back to the old version.

@zekje
Copy link

zekje commented Jul 2, 2023

Solved for my by remplacing
power_precision: ' '
by
power_precision: 0
in /config/zigbee2mqtt/devices.yaml
(and reload z2m )

@alray31
Copy link

alray31 commented Jul 2, 2023

Maybe in fact this issue should be opened against ZB2MQTT frontend?

Done
nurikk/zigbee2mqtt-frontend#1750

@zzz676
Copy link

zzz676 commented Jul 2, 2023

I got rid of the error by removing the power_calibration: '' line from the zigbee2mqtt config

Thanks. Removed this line, now there are no more errors.

@Gybrsh
Copy link

Gybrsh commented Jul 3, 2023

Make sure in your zigbee2mqtt configuration that e.g. energy_calibration is a number not string.

This did the trick. I had a space in one of my smartplugs power_calibration, replaced it with a 0 (zero).

@Coldness00
Copy link

Hello,
As I run this from Docker, I just reinstall the DOcker with the specific ver: koenkk/zigbee2mqtt:1.31.2

Worked well

@Nardol
Copy link
Author

Nardol commented Jul 3, 2023

So I close this issue which is more related to the frontend, thanks @alray31 for opening nurikk/zigbee2mqtt-frontend#1750

@Nardol Nardol closed this as completed Jul 3, 2023
Koenkk added a commit to Koenkk/zigbee-herdsman-converters that referenced this issue Jul 4, 2023
@Koenkk
Copy link
Owner

Koenkk commented Jul 4, 2023

Pushed a fix!

Changes will be available in the dev branch in a few hours from now. (https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html)

@Kepro
Copy link

Kepro commented Jul 8, 2023

hey @Koenkk I have HA with z2m -> 1.32.1-1 which should have Updated Zigbee2MQTT to version [1.32.1] which should be included in 1.32.1 release but issue still persist

@Koenkk Koenkk reopened this Jul 8, 2023
@Koenkk
Copy link
Owner

Koenkk commented Jul 8, 2023

Can you provide the debug log with 1.32.1?

@Kepro
Copy link

Kepro commented Jul 8, 2023

here

Zigbee2MQTT:debug 2023-07-08 18:24:22: Received Zigbee message from 'Air Quality', type 'commandDataReport', cluster 'manuSpecificTuya', data '{"dpValues":[{"data":{"data":[0,0,0,242],"type":"Buffer"},"datatype":2,"dp":18}],"seq":0}' from endpoint 1 with groupID 0
Zigbee2MQTT:error 2023-07-08 18:24:22: Exception while calling fromZigbee converter: 'temperature_calibration' is not a number, got string ()}
Zigbee2MQTT:debug 2023-07-08 18:24:22: Error: 'temperature_calibration' is not a number, got string ()
    at toNumber (/app/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:509:15)
    at Object.calibrateAndPrecisionRoundOptions (/app/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:89:29)
    at Object.convert (/app/node_modules/zigbee-herdsman-converters/src/lib/legacy.ts:3981:44)
    at Receive.onDeviceMessage (/app/lib/extension/receive.ts:150:51)
    at EventEmitter.emit (node:events:525:35)
    at EventBus.emitDeviceMessage (/app/lib/eventBus.ts:102:22)
    at Controller.<anonymous> (/app/lib/zigbee.ts:106:27)
    at Controller.emit (node:events:513:28)
    at Controller.selfAndDeviceEmit (/app/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14)
    at Controller.onZclOrRawData (/app/node_modules/zigbee-herdsman/src/controller/controller.ts:726:18)
Zigbee2MQTT:info  2023-07-08 18:24:22: MQTT publish: topic 'zigbee2mqtt/Air Quality', payload '{"co2":362,"formaldehyd":2,"humidity":56.2,"last_seen":"2023-07-08T16:24:22.106Z","linkquality":153,"temperature":24,"voc":1}'
Zigbee2MQTT:debug 2023-07-08 18:24:22: Received Zigbee message from 'Air Quality', type 'commandDataReport', cluster 'manuSpecificTuya', data '{"dpValues":[{"data":{"data":[0,0,2,46],"type":"Buffer"},"datatype":2,"dp":19}],"seq":0}' from endpoint 1 with groupID 0

okay, looks like this device had temperature_calibration: '' for some reason in YAML :-X Please close the issue it's fixed when I removed it

@Koenkk
Copy link
Owner

Koenkk commented Jul 9, 2023

'' is indeed not a valid number so the error is correct.

@kam821
Copy link

kam821 commented Jul 11, 2023

'' is indeed not a valid number so the error is correct.

@Koenkk
All you need is click on the value field (of e.g. power_calibration) in Firefox to make the entry: '' reappear in YAML configuration file.
This issue is still present in latest and latest-dev branches, latest usable version is 1.31.2, which also generates this entry, but doesn't panic about it.

@Kepro
Copy link

Kepro commented Jul 11, 2023

this is most likely an issue with the Frotnend part/package not this package... which has more issues with inputs and numbers...

@Koenkk
Copy link
Owner

Koenkk commented Jul 11, 2023

Please create an issue in the frontend repo: https://github.com/nurikk/zigbee2mqtt-frontend

@Nardol
Copy link
Author

Nardol commented Jul 11, 2023

Except if there is now something different, nurikk/zigbee2mqtt-frontend#1750 is still opened.

@popy2k14
Copy link

popy2k14 commented Aug 4, 2023

Similar log entries here. I did not changed any device in my network and did not had such messages.
Here is an log entry:

Debug 2023-08-04 15:38:24Error: 'illuminance_calibration' is not a number, got string () at toNumber (/app/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:509:15) at calibrateAndPrecisionRoundOptions (/app/node_modules/zigbee-herdsman-converters/src/lib/utils.ts:89:29) at Object.convert (/app/node_modules/zigbee-herdsman-converters/src/converters/fromZigbee.js:4052:35) at Receive.onDeviceMessage (/app/lib/extension/receive.ts:150:51) at EventEmitter.emit (node:events:525:35) at EventBus.emitDeviceMessage (/app/lib/eventBus.ts:102:22) at Controller.<anonymous> (/app/lib/zigbee.ts:107:27) at Controller.emit (node:events:513:28) at Controller.selfAndDeviceEmit (/app/node_modules/zigbee-herdsman/src/controller/controller.ts:515:14) at Controller.onZclOrRawData (/app/node_modules/zigbee-herdsman/src/controller/controller.ts:726:18)

@Kepro
Copy link

Kepro commented Aug 4, 2023

@popy2k14 did you check your configuration.yaml?

@popy2k14
Copy link

popy2k14 commented Aug 4, 2023

@Kepro thx for the hint. In my configuration.yaml was illuminance_calibration: '' for one device. Removed it, restarted Z2M and issue is gone. Dont know why this value was in there.

Anyway, it's solved now.
thx a lot

@pkasarda
Copy link

pkasarda commented Aug 4, 2023

@popy2k14 so same as I wrote above, it is an issue with frontend, adding empty string to config.. issue nurikk/zigbee2mqtt-frontend#1750

btw if you read a couple of messages above you will find out what to do :-P

@popy2k14
Copy link

popy2k14 commented Aug 5, 2023

Thx for the hint.

Those who can read have a clear advantage 😉😂

@github-actions
Copy link
Contributor

github-actions bot commented Sep 5, 2023

This issue is stale because it has been open 30 days with no activity. Remove stale label or comment or this will be closed in 7 days

@github-actions github-actions bot added the stale Stale issues label Sep 5, 2023
@github-actions github-actions bot closed this as not planned Won't fix, can't repro, duplicate, stale Sep 13, 2023
@xelemorf
Copy link

xelemorf commented Oct 31, 2023

I had the same with voltage_calibration: ''
Did a find/replace for it and seems to be resolved.

Find: voltage_calibration: ''
Replace: voltage_calibration: '0'

Need to do the same with all powered devices apparently.

@AndKe
Copy link

AndKe commented Nov 26, 2023

updated docker gave me "1.33.2 commit: 9996c93" - and I still see this issue?

@AndKe
Copy link

AndKe commented Jan 21, 2024

still the same issue with 1.35.1 commit: 9eaaa0f
"Failed to apply calibration to 'pressure': 'pressure_calibration' is not a number, got string ()"

is this going to get fixed?

@Kepro
Copy link

Kepro commented Jan 22, 2024

@AndKe you didn't even try to read the whole issue, right? ad 1 remove pressure_calibration from yaml manually, ad 2, it is or it was issue with frontend not with core package

@AndKe
Copy link

AndKe commented Jan 23, 2024

@Kepro thanks, no the issue consists of lots of posts, and none contains a described workaround.
I understood that there is a file in one of the docker volumes, named configuration.yaml
So far, I can only guess that I am looking for something like:
pressure_calibration : ''
which should be corrected to
pressure_calibration :

  • and I still hoped for the frontend or core, to handle such invalid setting from a previous build, simply correcting it on load .

@hellcry37
Copy link

hellcry37 commented Jan 23, 2024

@Kepro thanks, no the issue consists of lots of posts, and none contains a described workaround. I understood that there is a file in one of the docker volumes, named configuration.yaml So far, I can only guess that I am looking for something like: pressure_calibration : '' which should be corrected to pressure_calibration :

* and I still hoped for the frontend or core, to handle such invalid setting from a previous build, simply correcting it on load .

no man just remove in configuration.yaml or devices.yaml or what you have it set to, entire line.

for example I have this device:

'0x00xxxxxxxxxxxxx8':
  friendly_name: Master Bedroom Motion
  temperature_calibration: 2
  temperature_precision: 1

now if is set like this will error out:

'0x00xxxxxxxxxxxxx8':
  friendly_name: Master Bedroom Motion
  temperature_calibration: 2
  temperature_precision: ''

because temperature_precision is NULL

Observe how values between quotes are strings and no quotes are usually numbers (this is not mandatory) depends on the programming language but usually is like this. - hope this addresses comments about strings and stuff!

For this error to be gone remove the hole line that contains the null string in this case: temperature_precision: ''

Restart zigbee2mqtt

note: I had exactly this explained half a year ago, others did to (on Jul 2, 2023) read the thread please

@AndKe
Copy link

AndKe commented Jan 25, 2024

Thank you, fixed it after locating the file in docker. - I hoped this was automatically handled in newer releases.