You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
For period t = 1 only, the constraints on storage dispatch and base scenario energy bounds, (4.33)-(4.34) in the MOST manual, are currently implemented as though rho = 1, independent of the actual value of rho.
The difference is a subtle one, with the stored energy at t = 0 represented by mdi.Storage.InitialStorage for rho = 0 and by the bounds mdi.Storage.InitialStorage[Lower/Upper]Bound for rho = 1.
The text was updated successfully, but these errors were encountered:
For period t = 1 only, the constraints on storage dispatch and base scenario energy bounds, (4.33)-(4.34) in the MOST manual, are currently implemented as though
rho = 1
, independent of the actual value ofrho
.The difference is a subtle one, with the stored energy at t = 0 represented by
mdi.Storage.InitialStorage
forrho = 0
and by the boundsmdi.Storage.InitialStorage[Lower/Upper]Bound
forrho = 1
.The text was updated successfully, but these errors were encountered: