Hi
I am a newbie, so please check my contribution.
Setting up autolevelling was a pain in the a*** because this guide was totally outdated.
What's still missing is a description of how to set the borders right.
I do not fully understand this part, ie it does not work yet as expected.

this was done with Marlin 2.1.2.2 on two Creality configs that do not yet exist in the repo.
Should I already post them even if I am not finished yet?

@@ -24,7 +24,7 @@ UBL is a superset of previous automatic leveling systems, but it does not necess

The printer must be already fully functional and tested, with a well-constrained movement system. The more physically level and straight the bed is, the better your results will be. See `Configuration.h` and `Configuration_adv.h` for all of UBL's settings.

You should be able to successfully print a small object at the center of the bed with bed leveling turned off. It's very important to verify that your `Configuration.h` settings make this possible before trying to bring up UBL. Most problems bringing up the UBL Bed Leveling system occur when this step has been ignored. Please pay particular attention to your `Z_PROBE_OFFSET_FROM_EXTRUDER` value. Usually it's best to home the Z-Axis in the center of the bed. But wherever you decide to home, the Z value reported on the LCD (or with [`M114`](/docs/gcode/M114.html)) should be _very_ close to 0.0 mm when the nozzle is just touching the bed. Failure to calibrate `Z_PROBE_OFFSET_FROM_EXTRUDER` properly will result in dimensional errors in your printed parts.
You should be able to successfully print a small object at the center of the bed with bed leveling turned off. It's very important to verify that your `Configuration.h` settings make this possible before trying to bring up UBL. Most problems bringing up the UBL Bed Leveling system occur when this step has been ignored. Please pay particular attention to your `Z_PROBE_OFFSET_FROM_EXTRUDER` value (`NOZZLE_TO_PROBE_OFFSET` in Marilin 2.1). Usually it's best to home the Z-Axis in the center of the bed. But wherever you decide to home, the Z value reported on the LCD (or with [`M114`](/docs/gcode/M114.html)) should be _very_ close to 0.0 mm when the nozzle is just touching the bed. Failure to calibrate `Z_PROBE_OFFSET_FROM_EXTRUDER` properly will result in dimensional errors in your printed parts.
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Suggested change
You should be able to successfully print a small object at the center of the bed with bed leveling turned off. It's very important to verify that your `Configuration.h` settings make this possible before trying to bring up UBL. Most problems bringing up the UBL Bed Leveling system occur when this step has been ignored. Please pay particular attention to your `Z_PROBE_OFFSET_FROM_EXTRUDER` value (`NOZZLE_TO_PROBE_OFFSET` in Marilin 2.1). Usually it's best to home the Z-Axis in the center of the bed. But wherever you decide to home, the Z value reported on the LCD (or with [`M114`](/docs/gcode/M114.html)) should be _very_ close to 0.0 mm when the nozzle is just touching the bed. Failure to calibrate `Z_PROBE_OFFSET_FROM_EXTRUDER` properly will result in dimensional errors in your printed parts.
You should be able to successfully print a small object at the center of the bed with bed leveling turned off. It's very important to verify that your `Configuration.h` settings make this possible before trying to bring up UBL. Most problems bringing up the UBL Bed Leveling system occur when this step has been ignored. Please pay particular attention to your `Z_PROBE_OFFSET_FROM_EXTRUDER` value (`NOZZLE_TO_PROBE_OFFSET` in Marlin 2.1). Usually it's best to home the Z-Axis in the center of the bed. But wherever you decide to home, the Z value reported on the LCD (or with [`M114`](/docs/gcode/M114.html)) should be _very_ close to 0.0 mm when the nozzle is just touching the bed. Failure to calibrate `Z_PROBE_OFFSET_FROM_EXTRUDER` properly will result in dimensional errors in your printed parts.

@sjasonsmith
Copy link
Contributor

Perhaps @thisiskeithb or @ellensp could look this over and suggest whether they think the changes are worthwhile.