Skip to content

Commit

Permalink
Simplify extrapolation bounds.
Browse files Browse the repository at this point in the history
  • Loading branch information
shorowit committed Jan 3, 2025
1 parent 5a8c811 commit 143b37e
Show file tree
Hide file tree
Showing 2 changed files with 28 additions and 83 deletions.
6 changes: 3 additions & 3 deletions HPXMLtoOpenStudio/measure.xml
Original file line number Diff line number Diff line change
Expand Up @@ -3,8 +3,8 @@
<schema_version>3.1</schema_version>
<name>hpxm_lto_openstudio</name>
<uid>b1543b30-9465-45ff-ba04-1d1f85e763bc</uid>
<version_id>c58ea94a-6212-4c94-b852-241fcd694bc9</version_id>
<version_modified>2025-01-03T23:32:21Z</version_modified>
<version_id>cdbf2c2a-f1ea-4b0f-beda-be89fe3ec62f</version_id>
<version_modified>2025-01-03T23:43:25Z</version_modified>
<xml_checksum>D8922A73</xml_checksum>
<class_name>HPXMLtoOpenStudio</class_name>
<display_name>HPXML to OpenStudio Translator</display_name>
Expand Down Expand Up @@ -387,7 +387,7 @@
<filename>hvac.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>3696F857</checksum>
<checksum>6C956C9C</checksum>
</file>
<file>
<filename>hvac_sizing.rb</filename>
Expand Down
105 changes: 25 additions & 80 deletions HPXMLtoOpenStudio/resources/hvac.rb
Original file line number Diff line number Diff line change
Expand Up @@ -36,8 +36,8 @@ def self.apply_hvac_systems(runner, model, weather, spaces, hpxml_bldg, hpxml_he
apply_unit_multiplier(hpxml_bldg, hpxml_header)
ensure_nonzero_sizing_values(hpxml_bldg)
apply_ideal_air_system(model, weather, spaces, hpxml_bldg, hpxml_header, hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
apply_cooling_system(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map, hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
hp_backup_obj = apply_heating_system(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map, hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
apply_cooling_system(runner, model, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map, hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
hp_backup_obj = apply_heating_system(runner, model, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map, hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
apply_heat_pump(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map, hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs, hp_backup_obj)

return airloop_map
Expand All @@ -48,7 +48,6 @@ def self.apply_hvac_systems(runner, model, weather, spaces, hpxml_bldg, hpxml_he
#
# @param runner [OpenStudio::Measure::OSRunner] Object typically used to display warnings
# @param model [OpenStudio::Model::Model] OpenStudio Model object
# @param weather [WeatherFile] Weather object containing EPW information
# @param spaces [Hash] Map of HPXML locations => OpenStudio Space objects
# @param hpxml_bldg [HPXML::Building] HPXML Building object representing an individual dwelling unit
# @param hpxml_header [HPXML::Header] HPXML Header object (one per HPXML file)
Expand All @@ -58,7 +57,7 @@ def self.apply_hvac_systems(runner, model, weather, spaces, hpxml_bldg, hpxml_he
# @param hvac_unavailable_periods [Hash] Map of htg/clg => HPXML::UnavailablePeriods for heating/cooling
# @param hvac_remaining_load_fracs [Hash] Map of htg/clg => Fraction of heating/cooling load that has not yet been met
# @return [nil]
def self.apply_cooling_system(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map,
def self.apply_cooling_system(runner, model, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map,
hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
conditioned_zone = spaces[HPXML::LocationConditionedSpace].thermalZone.get

Expand Down Expand Up @@ -92,7 +91,7 @@ def self.apply_cooling_system(runner, model, weather, spaces, hpxml_bldg, hpxml_
case cooling_system.cooling_system_type
when HPXML::HVACTypeCentralAirConditioner, HPXML::HVACTypeRoomAirConditioner,
HPXML::HVACTypeMiniSplitAirConditioner, HPXML::HVACTypePTAC
airloop_map[sys_id] = apply_air_source_hvac_systems(runner, model, weather, cooling_system, heating_system, hvac_sequential_load_fracs,
airloop_map[sys_id] = apply_air_source_hvac_systems(runner, model, cooling_system, heating_system, hvac_sequential_load_fracs,
conditioned_zone, hvac_unavailable_periods, schedules_file, hpxml_bldg, hpxml_header)
when HPXML::HVACTypeEvaporativeCooler
airloop_map[sys_id] = apply_evaporative_cooler(model, cooling_system, hvac_sequential_load_fracs, conditioned_zone, hvac_unavailable_periods,
Expand All @@ -106,7 +105,6 @@ def self.apply_cooling_system(runner, model, weather, spaces, hpxml_bldg, hpxml_
#
# @param runner [OpenStudio::Measure::OSRunner] Object typically used to display warnings
# @param model [OpenStudio::Model::Model] OpenStudio Model object
# @param weather [WeatherFile] Weather object containing EPW information
# @param spaces [Hash] Map of HPXML locations => OpenStudio Space objects
# @param hpxml_bldg [HPXML::Building] HPXML Building object representing an individual dwelling unit
# @param hpxml_header [HPXML::Header] HPXML Header object (one per HPXML file)
Expand All @@ -116,7 +114,7 @@ def self.apply_cooling_system(runner, model, weather, spaces, hpxml_bldg, hpxml_
# @param hvac_unavailable_periods [Hash] Map of htg/clg => HPXML::UnavailablePeriods for heating/cooling
# @param hvac_remaining_load_fracs [Hash] Map of htg/clg => Fraction of heating/cooling load that has not yet been met
# @return [TODO] TODO
def self.apply_heating_system(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map,
def self.apply_heating_system(runner, model, spaces, hpxml_bldg, hpxml_header, schedules_file, airloop_map,
hvac_season_days, hvac_unavailable_periods, hvac_remaining_load_fracs)
conditioned_zone = spaces[HPXML::LocationConditionedSpace].thermalZone.get
hp_backup_obj = nil
Expand Down Expand Up @@ -152,7 +150,7 @@ def self.apply_heating_system(runner, model, weather, spaces, hpxml_bldg, hpxml_
sys_id = heating_system.id
case heating_system.heating_system_type
when HPXML::HVACTypeFurnace
airloop_map[sys_id] = apply_air_source_hvac_systems(runner, model, weather, nil, heating_system, hvac_sequential_load_fracs,
airloop_map[sys_id] = apply_air_source_hvac_systems(runner, model, nil, heating_system, hvac_sequential_load_fracs,
conditioned_zone, hvac_unavailable_periods, schedules_file, hpxml_bldg, hpxml_header)
when HPXML::HVACTypeBoiler
airloop_map[sys_id] = apply_boiler(runner, model, heating_system, hvac_sequential_load_fracs, conditioned_zone, hvac_unavailable_periods)
Expand Down Expand Up @@ -215,7 +213,7 @@ def self.apply_heat_pump(runner, model, weather, spaces, hpxml_bldg, hpxml_heade
airloop_map[sys_id] = apply_water_loop_to_air_heat_pump(model, heat_pump, hvac_sequential_load_fracs, conditioned_zone, hvac_unavailable_periods)
when HPXML::HVACTypeHeatPumpAirToAir, HPXML::HVACTypeHeatPumpMiniSplit,
HPXML::HVACTypeHeatPumpPTHP, HPXML::HVACTypeHeatPumpRoom
airloop_map[sys_id] = apply_air_source_hvac_systems(runner, model, weather, heat_pump, heat_pump, hvac_sequential_load_fracs,
airloop_map[sys_id] = apply_air_source_hvac_systems(runner, model, heat_pump, heat_pump, hvac_sequential_load_fracs,
conditioned_zone, hvac_unavailable_periods, schedules_file, hpxml_bldg, hpxml_header)
when HPXML::HVACTypeHeatPumpGroundToAir
airloop_map[sys_id] = apply_ground_to_air_heat_pump(runner, model, weather, heat_pump, hvac_sequential_load_fracs,
Expand All @@ -237,7 +235,6 @@ def self.apply_heat_pump(runner, model, weather, spaces, hpxml_bldg, hpxml_heade
#
# @param runner [OpenStudio::Measure::OSRunner] Object typically used to display warnings
# @param model [OpenStudio::Model::Model] OpenStudio Model object
# @param weather [WeatherFile] Weather object containing EPW information
# @param cooling_system [HPXML::CoolingSystem or HPXML::HeatPump] The HPXML cooling system or heat pump of interest
# @param heating_system [HPXML::HeatingSystem or HPXML::HeatPump] The HPXML heating system or heat pump of interest
# @param hvac_sequential_load_fracs [Array<Double>] Array of daily fractions of remaining heating/cooling load to bet met by the HVAC system
Expand All @@ -247,7 +244,7 @@ def self.apply_heat_pump(runner, model, weather, spaces, hpxml_bldg, hpxml_heade
# @param hpxml_bldg [HPXML::Building] HPXML Building object representing an individual dwelling unit
# @param hpxml_header [HPXML::Header] HPXML Header object (one per HPXML file)
# @return [OpenStudio::Model::AirLoopHVAC] The newly created air loop hvac object
def self.apply_air_source_hvac_systems(runner, model, weather, cooling_system, heating_system, hvac_sequential_load_fracs,
def self.apply_air_source_hvac_systems(runner, model, cooling_system, heating_system, hvac_sequential_load_fracs,
control_zone, hvac_unavailable_periods, schedules_file, hpxml_bldg, hpxml_header)
is_heatpump = false

Expand Down Expand Up @@ -353,7 +350,7 @@ def self.apply_air_source_hvac_systems(runner, model, weather, cooling_system, h
fan_cfms = []
if not cooling_system.nil?
# Cooling Coil
clg_coil = create_dx_cooling_coil(model, obj_name, cooling_system, max_rated_fan_cfm, weather.data.AnnualMaxDrybulb, has_deadband_control)
clg_coil = create_dx_cooling_coil(model, obj_name, cooling_system, max_rated_fan_cfm, has_deadband_control)

clg_cfm = cooling_system.cooling_airflow_cfm
clg_ap.cool_fan_speed_ratios.each do |r|
Expand Down Expand Up @@ -392,7 +389,7 @@ def self.apply_air_source_hvac_systems(runner, model, weather, cooling_system, h
end

# Heating Coil
htg_coil = create_dx_heating_coil(model, obj_name, heating_system, max_rated_fan_cfm, weather.data.AnnualMinDrybulb, hpxml_header.defrost_model_type, p_dot_defrost, has_deadband_control)
htg_coil = create_dx_heating_coil(model, obj_name, heating_system, max_rated_fan_cfm, hpxml_header.defrost_model_type, p_dot_defrost, has_deadband_control)

# Supplemental Heating Coil
htg_supp_coil = create_supp_heating_coil(model, obj_name, heating_system, hpxml_header, runner, hpxml_bldg)
Expand Down Expand Up @@ -1100,7 +1097,7 @@ def self.apply_ideal_air_system(model, weather, spaces, hpxml_bldg, hpxml_header
elsif weather.header.StateProvinceRegion.downcase == 'nv'
heating_load_frac = 0.0
else
fail 'Unexpected weather file for ASHRAE 140 run.'
fail 'Unexpected location for ASHRAE 140 run.'
end
end
hvac_sequential_load_fracs = { htg: [heating_load_frac],
Expand Down Expand Up @@ -2818,9 +2815,8 @@ def self.convert_net_to_gross_capacity_cop(net_cap, fan_power, mode, net_cop = n
# @param mode [Symbol] Heating (:htg) or cooling (:clg)
# @param max_rated_fan_cfm [Double] Maximum rated fan flow rate
# @param hp_temp [Double] Minimum (for heating) or maximum (for cooling) heat pump compressor operating temperature
# @param weather_temp [Double] Minimum (for heating) or maximum (for cooling) outdoor drybulb temperature
# @return [nil]
def self.process_neep_detailed_performance(hvac_system, mode, max_rated_fan_cfm, hp_temp, weather_temp)
def self.process_neep_detailed_performance(hvac_system, mode, max_rated_fan_cfm, hp_temp)
detailed_performance_data_name = (mode == :clg) ? 'cooling_detailed_performance_data' : 'heating_detailed_performance_data'
detailed_performance_data = hvac_system.send(detailed_performance_data_name)
hvac_ap = hvac_system.additional_properties
Expand Down Expand Up @@ -2852,7 +2848,7 @@ def self.process_neep_detailed_performance(hvac_system, mode, max_rated_fan_cfm,
end

convert_data_points_net_to_gross(data_array, hvac_system, mode, cfm_per_ton, max_rated_fan_cfm)
extrapolate_data_points(data_array, mode, hp_temp, weather_temp)
extrapolate_data_points(data_array, mode, hp_temp)
convert_data_points_net_to_gross(data_array, hvac_system, mode, cfm_per_ton, max_rated_fan_cfm)
add_data_point_adaptive_step_size(data_array, mode)
convert_data_points_net_to_gross(data_array, hvac_system, mode, cfm_per_ton, max_rated_fan_cfm)
Expand Down Expand Up @@ -2886,35 +2882,23 @@ def self.convert_data_points_net_to_gross(data_array, hvac_system, mode, cfm_per
# @param data_array [TODO] TODO
# @param mode [Symbol] Heating (:htg) or cooling (:clg)
# @param hp_temp [Double] Minimum (for heating) or maximum (for cooling) heat pump compressor operating temperature
# @param weather_temp [Double] Minimum (for heating) or maximum (for cooling) outdoor drybulb temperature
# @return [nil]
def self.extrapolate_data_points(data_array, mode, hp_temp, weather_temp)
def self.extrapolate_data_points(data_array, mode, hp_temp)
# Set of data used for table lookup
data_array.each do |data|
user_odbs = data.map { |dp| dp.outdoor_temperature }
# Determine min/max ODB temperatures to cover full range of equipment operation
outdoor_dry_bulbs = []
if mode == :clg
# Calculate ODB temperature at which COP or capacity is zero, so we don't extrapolate beyond that and get negative values
high_odb_at_zero_cop = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_efficiency_cop, true)
high_odb_at_zero_capacity = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_capacity, true)
low_odb_at_zero_cop = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_efficiency_cop, false)
low_odb_at_zero_capacity = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_capacity, false)

outdoor_dry_bulbs << [low_odb_at_zero_cop, low_odb_at_zero_capacity, 60.0].max # Min cooling ODB
outdoor_dry_bulbs << [high_odb_at_zero_cop, high_odb_at_zero_capacity, hp_temp, weather_temp].min # Max cooling ODB
# Extrapolate to 60F and maximum HP operating temperature
outdoor_dry_bulbs << 60.0
outdoor_dry_bulbs << hp_temp
else
# Calculate ODB temperature at which COP or capacity is zero, so we don't extrapolate beyond that and get negative values
low_odb_at_zero_cop = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_efficiency_cop, false)
low_odb_at_zero_capacity = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_capacity, false)
high_odb_at_zero_cop = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_efficiency_cop, true)
high_odb_at_zero_capacity = calculate_odb_at_zero_cop_or_capacity(data, user_odbs, :gross_capacity, true)

outdoor_dry_bulbs << [low_odb_at_zero_cop, low_odb_at_zero_capacity, hp_temp, weather_temp].max # Min heating ODB
outdoor_dry_bulbs << [high_odb_at_zero_cop, high_odb_at_zero_capacity, 60.0].min # Max heating ODB
# Extrapolate to minimum HP operating temperature and 60F
outdoor_dry_bulbs << hp_temp
outdoor_dry_bulbs << 60.0
end

capacity_description = data[0].capacity_description
user_odbs = data.map { |dp| dp.outdoor_temperature }
outdoor_dry_bulbs.each do |target_odb|
next if user_odbs.include? target_odb

Expand All @@ -2936,43 +2920,6 @@ def self.extrapolate_data_points(data_array, mode, hp_temp, weather_temp)
end
end

# TODO
#
# @param data [TODO] TODO
# @param user_odbs [TODO] TODO
# @param property [TODO] TODO
# @param find_high [TODO] TODO
# @return [TODO] TODO
def self.calculate_odb_at_zero_cop_or_capacity(data, user_odbs, property, find_high)
if find_high
odb_dp1 = data.find { |dp| dp.outdoor_temperature == user_odbs[-1] }
odb_dp2 = data.find { |dp| dp.outdoor_temperature == user_odbs[-2] }
else
odb_dp1 = data.find { |dp| dp.outdoor_temperature == user_odbs[0] }
odb_dp2 = data.find { |dp| dp.outdoor_temperature == user_odbs[1] }
end

slope = (odb_dp1.send(property) - odb_dp2.send(property)) / (odb_dp1.outdoor_temperature - odb_dp2.outdoor_temperature)

# Datapoints don't trend toward zero COP?
if (find_high && slope >= 0)
return 999999.0
elsif (!find_high && slope <= 0)
return -999999.0
end

intercept = odb_dp2.send(property) - (slope * odb_dp2.outdoor_temperature)
target_odb = -intercept / slope

# Return a slightly larger (or smaller, for cooling) ODB so things don't blow up
delta_odb = 1.0
if find_high
return target_odb - delta_odb
else
return target_odb + delta_odb
end
end

# Extrapolates the given performance property for the specified outdoor drybulb temperature
# per RESNET MINHERS Addendum 82:
# - Cooling, Min ODB: Linear from 82°F and 95°F cooling performance, but no less than 50% of the value at 82°F
Expand Down Expand Up @@ -3149,10 +3096,9 @@ def self.correct_ft_cap_eir(data_array, mode)
# @param obj_name [String] Name for the OpenStudio object
# @param cooling_system [HPXML::CoolingSystem or HPXML::HeatPump] The HPXML cooling system or heat pump of interest
# @param max_rated_fan_cfm [TODO] TODO
# @param weather_max_drybulb [Double] Maximum outdoor drybulb temperature
# @param has_deadband_control [Boolean] Whether to apply on off thermostat deadband
# @return [TODO] TODO
def self.create_dx_cooling_coil(model, obj_name, cooling_system, max_rated_fan_cfm, weather_max_drybulb, has_deadband_control = false)
def self.create_dx_cooling_coil(model, obj_name, cooling_system, max_rated_fan_cfm, has_deadband_control = false)
clg_ap = cooling_system.additional_properties

if cooling_system.cooling_detailed_performance_data.empty?
Expand All @@ -3168,7 +3114,7 @@ def self.create_dx_cooling_coil(model, obj_name, cooling_system, max_rated_fan_c
clg_ap.cool_rated_capacities_gross << gross_capacity
end
else
process_neep_detailed_performance(cooling_system, :clg, max_rated_fan_cfm, cooling_system.compressor_maximum_temp, weather_max_drybulb)
process_neep_detailed_performance(cooling_system, :clg, max_rated_fan_cfm, cooling_system.compressor_maximum_temp)
end

clg_coil = nil
Expand Down Expand Up @@ -3298,12 +3244,11 @@ def self.create_dx_cooling_coil(model, obj_name, cooling_system, max_rated_fan_c
# @param obj_name [String] Name for the OpenStudio object
# @param heating_system [HPXML::HeatingSystem or HPXML::HeatPump] The HPXML heating system or heat pump of interest
# @param max_rated_fan_cfm [TODO] TODO
# @param weather_min_drybulb [Double] Minimum outdoor drybulb temperature
# @param defrost_model_type [String] Defrost model type (HPXML::AdvancedResearchDefrostModelTypeXXX)
# @param p_dot_defrost [TODO] TODO
# @param has_deadband_control [Boolean] Whether to apply on off thermostat deadband
# @return [TODO] TODO
def self.create_dx_heating_coil(model, obj_name, heating_system, max_rated_fan_cfm, weather_min_drybulb, defrost_model_type, p_dot_defrost, has_deadband_control = false)
def self.create_dx_heating_coil(model, obj_name, heating_system, max_rated_fan_cfm, defrost_model_type, p_dot_defrost, has_deadband_control = false)
htg_ap = heating_system.additional_properties

if heating_system.heating_detailed_performance_data.empty?
Expand All @@ -3319,7 +3264,7 @@ def self.create_dx_heating_coil(model, obj_name, heating_system, max_rated_fan_c
htg_ap.heat_rated_capacities_gross << gross_capacity
end
else
process_neep_detailed_performance(heating_system, :htg, max_rated_fan_cfm, htg_ap.hp_min_temp, weather_min_drybulb)
process_neep_detailed_performance(heating_system, :htg, max_rated_fan_cfm, htg_ap.hp_min_temp)
end

htg_coil = nil
Expand Down

0 comments on commit 143b37e