Issue overview
In 22.2.0, there’s a new error in ZoneHVAC:PackagedTerminal:AC/HP if you don’t supply a Supply Air Fan Operating Mode Schedule when you have a Fan:ConstantVolume
** Severe ** ZoneHVAC:PackagedTerminalAirConditioner = ZONE HVAC PACKAGED TERMINAL AIR CONDITIONER 4
** ~~~ ** Fan type must be Fan:OnOff or Fan:SystemModel when Supply Air Fan Operating Mode Schedule Name is blank
Except:
- if I pass a Always 0 schedule, there’s another error saying value must be > 0 for Fan:CV.
- If I pass Always 1 schedule, my EUI changes quite dramatically.
- If I use a Fan:OnOff with always 0, my EUI is closer but still different.
We need a way to handle this so we don't end up with too broken models (lots are failing on OS-resources right now) and ideally without changing EUI too drastically.
cf 9abf9e4#diff-6792272e2d22af45d561660c93bc735d74a30b2a15218ed60d1b05a91eeca176R310