Zib-Bowelfunction #1375
This run and associated checks have been archived and are scheduled for deletion.
Learn more about checks retention
qa-all.yml
on: pull_request
Loose QA on the entire repo
9m 11s
Annotations
10 errors and 10 warnings
Loose QA on the entire repo:
resources/zib/zib-StrongKidsScore.xml#L36
Error in invariant 'zib-StrongKidsScore-1' with expression 'component.where(code.coding.system='urn:oid:2.16.840.1.113883.2.4.3.11.60.40.4.0.1' and code.coding.code.subsetOf('4028003'|'4028004'|'4028005'|'4028008')).count().subsetOf(0|4)': Error evaluating FHIRPath expression: The parameter type http://hl7.org/fhirpath/System.String is not legal for subsetOf parameter 1. expecting SINGLETON[http://hl7.org/fhir/StructureDefinition/code] (@char 3)
|
Loose QA on the entire repo:
resources/zib/zib-StrongKidsScore.xml#L42
Error in invariant 'zib-StrongKidsScore-2' with expression 'value.empty().not() or component.where(code.coding.system='urn:oid:2.16.840.1.113883.2.4.3.11.60.40.4.0.1' and code.coding.code.subsetOf('4028003'|'4028004'|'4028005'|'4028008')).count()=4': Error evaluating FHIRPath expression: The parameter type http://hl7.org/fhirpath/System.String is not legal for subsetOf parameter 1. expecting SINGLETON[http://hl7.org/fhir/StructureDefinition/code] (@char 5)
|
Loose QA on the entire repo:
examples/nl-core-LaboratoryTestResult.Specimen-02.xml#L7
None of the codings provided are in the value set 'Monstermateriaal-en-Microorganisme-Codelijsten' (http://nictiz.nl/fhir/ValueSet/Monstermateriaal-en-Microorganisme-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://snomed.info/sct#87612001)
|
Loose QA on the entire repo:
examples/nl-core-Encounter-01.xml#L8
Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP - should be one of 1 choices: 'inpatient encounter' (for the language(s) 'en') for 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP'
|
Loose QA on the entire repo:
examples/nl-core-LaboratoryTestResult-01.xml#L22
None of the codings provided are in the value set 'TestCode-en-Onderzoek-Codelijsten' (http://nictiz.nl/fhir/ValueSet/TestCode-en-Onderzoek-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://loinc.org#2947-0)
|
Loose QA on the entire repo:
examples/nl-core-HealthProfessional-Practitioner-01.xml#L68
None of the codings provided are in the value set 'LandCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.10--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = urn:iso:std:iso:3166#NL)
|
Loose QA on the entire repo:
examples/nl-core-Patient-01.xml#L116
None of the codings provided are in the value set 'LandCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.10--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = urn:iso:std:iso:3166#NL)
|
Loose QA on the entire repo:
examples/nl-core-LaboratoryTestResult-03.xml#L22
None of the codings provided are in the value set 'TestCode-en-Onderzoek-Codelijsten' (http://nictiz.nl/fhir/ValueSet/TestCode-en-Onderzoek-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://loinc.org#22314-9)
|
Loose QA on the entire repo:
examples/nl-core-Vaccination-event-02.xml#L8
None of the codings provided are in the value set 'ProductCodeCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.17--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://www.whocc.no/atc#J07BC02)
|
Loose QA on the entire repo:
examples/nl-core-Alert-02.xml#L16
The code provided (http://snomed.info/sct#432415000) is not in the value set 'AlertNaamCodelijst' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.8.3.2--20200901000000|2020-09-01T00:00:00), and a code from this value set is required: Unable to check whether the code is in the value set http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.8.3.2--20200901000000|2020-09-01T00:00:00
|
Loose QA on the entire repo:
resources/zib/zib-Refraction.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.20.7.2--20200901000000 could not be expanded
|
Loose QA on the entire repo:
resources/zib/zib-HelpFromOthers.xml#L1
The slice definition for CarePlan.activity.detail.performer has a maximum of 1 but the slices add up to a maximum of 3. Check that this is what is intended
|
Loose QA on the entire repo:
resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
Loose QA on the entire repo:
resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
Loose QA on the entire repo:
resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 could not be expanded
|
Loose QA on the entire repo:
resources/zib/zib-HearingFunction.HearingAid.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
Loose QA on the entire repo:
resources/zib/zib-HearingFunction.HearingAid.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
Loose QA on the entire repo:
resources/zib/zib-HearingFunction.HearingAid.Product.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 could not be expanded
|
Loose QA on the entire repo:
resources/zib/zib-MedicalDevice.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
Loose QA on the entire repo:
resources/zib/zib-MedicalDevice.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|