Zib-TNMTumorClassification-UnitedStates #1428
Annotations
10 errors and 10 warnings
resources/nl-core/nl-core-TNMTumorClassification.xml#L49
Rule eld-1: 'If there are no discriminators, there must be a definition' Failed
|
resources/zib/pattern-VitalSigns.xml#L30
The invariant vs-2 defined in the differential must have no source, or the source must be the same as the profile
|
resources/zib/pattern-VitalSigns.xml#L83
The invariant vs-1 defined in the differential must have no source, or the source must be the same as the profile
|
resources/zib/pattern-VitalSigns.xml#L101
The invariant vs-3 defined in the differential must have no source, or the source must be the same as the profile
|
examples/nl-core-LaboratoryTestResult.Specimen-02.xml#L7
None of the codings provided are in the value set 'Monstermateriaal-en-Microorganisme-Codelijsten' (http://nictiz.nl/fhir/ValueSet/Monstermateriaal-en-Microorganisme-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://snomed.info/sct#87612001)
|
examples/nl-core-MedicalDevice-03.xml#L39
None of the codings provided are in the value set 'LocatieCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.11--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://snomed.info/sct#9454009)
|
examples/nl-core-Vaccination-event-02.xml#L8
None of the codings provided are in the value set 'ProductCodeCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.17--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://www.whocc.no/atc#J07BC02)
|
examples/nl-core-LaboratoryTestResult-LaboratoryTest-06.xml#L22
None of the codings provided are in the value set 'TestCode-en-Onderzoek-Codelijsten' (http://nictiz.nl/fhir/ValueSet/TestCode-en-Onderzoek-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://loinc.org#20570-8)
|
examples/nl-core-Vaccination-request-01.xml#L14
None of the codings provided are in the value set 'ProductCodeCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.17--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://www.whocc.no/atc#J07CA06)
|
examples/nl-core-Encounter-01.xml#L8
Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP - should be one of 1 choices: 'inpatient encounter' (for the language(s) 'en') for 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP'
|
resources/zib/zib-HearingFunction.HearingAid.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.11--20200901000000 could not be expanded
|
resources/zib/zib-NursingIntervention.xml#L1
The slice definition for CarePlan.activity.detail.performer has a maximum of 1 but the slices add up to a maximum of 3. Check that this is what is intended
|
resources/zib/zib-NursingIntervention.xml#L185
Canonical URL 'http://nictiz.nl/fhir/StructureDefinition/zib-TreatmentObjective' does not resolve
|
resources/zib/zib-NursingIntervention.xml#L1
Cannot check whether the target profile http://nictiz.nl/fhir/StructureDefinition/zib-TreatmentObjective on CarePlan.goal is valid constraint on the base because it is not known
|
resources/zib/zib-NursingIntervention.xml#L1
Unable to resolve profile http://nictiz.nl/fhir/StructureDefinition/zib-TreatmentObjective
|
resources/zib/zib-TNMTumorClassification.VVenousInvasion.xml#L62
Canonical URL 'http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.4.27.7--20200901000000' does not resolve
|
resources/zib/zib-TNMTumorClassification.VVenousInvasion.xml#L1
The valueSet reference http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.4.27.7--20200901000000 on element Observation.value[x] could not be resolved
|
resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
|
resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 could not be expanded
|
The logs for this run have expired and are no longer available.
Loading