Notifications
You must be signed in to change notification settings - Fork 7
Workflow Guide deskewing
Arne Rümmler edited this page Mar 17, 2023
·
2 revisions
In this processing step, a document image is taken as input and the skew of that page is corrected by annotating the detected angle (-45° .. 45°) and rotating the image. Optionally, also the orientation is corrected by annotating the detected angle (multiples of 90°) and transposing the image. The input images have to be binarized for this module to work.
Processor | Parameter | Remarks | Call |
---|---|---|---|
ocrd-cis-ocropy-deskew | -P level-of-operation page |
Recommended | ocrd-cis-ocropy-deskew -I OCR-D-DENOISE -O OCR-D-DESKEW-PAGE -P level-of-operation page |
ocrd-tesserocr-deskew | -P operation_level page |
Fast, also performs a decent orientation correction | ocrd-tesserocr-deskew -I OCR-D-DENOISE -O OCR-D-DESKEW-PAGE -P operation_level page |
E.g.
- which parameters do you use with what values?
- which parameters are insufficiently documented?
- which aspects of a processor should be parameterizable but are not?
E.g. which processors worked best with what material? -- feel free to post sample images here, too.
Welcome to the OCR-D wiki, a companion to the OCR-D website.
Articles and tutorials
- Running OCR-D on macOS
- Running OCR-D in Windows 10 with Windows Subsystem for Linux
- Running OCR-D on POWER8 (IBM pSeries)
- Running browse-ocrd in a Docker container
- OCR-D Installation on NVIDIA Jetson Nano and Xavier
- Mapping PAGE to ALTO
- Comparison of OCR formats (outdated)
- A Practicioner's View on Binarization
- How to use the bulk-add command to generate workspaces from existing files
- Evaluation of (intermediary) steps of an OCR workflow
- A quickstart guide to ocrd workspace
- Introduction to parameters in OCR-D
- Introduction to OCR-D processors
- Introduction to OCR-D workflows
- Visualizing (intermediate) OCR-D-results
- Guide to updating ocrd workspace calls for 2.15.0+
- Introduction to Docker in OCR-D
- How to import Abbyy-generated ALTO
- How to create ALTO for DFG Viewer
- How to create searchable fulltext data for DFG Viewer
- Setup native CUDA Toolkit for Qurator tools on Ubuntu 18.04
- OCR-D Code Review Guidelines
- OCR-D Recommendations for Using CI in Your Repository
Expert section on OCR-D- workflows
Particular workflow steps
Workflow Guide
- Workflow Guide: preprocessing
- Workflow Guide: binarization
- Workflow Guide: cropping
- Workflow Guide: denoising
- Workflow Guide: deskewing
- Workflow Guide: dewarping
- Workflow Guide: region-segmentation
- Workflow Guide: clipping
- Workflow Guide: line-segmentation
- Workflow Guide: resegmentation
- Workflow Guide: olr-evaluation
- Workflow Guide: text-recognition
- Workflow Guide: text-alignment
- Workflow Guide: post-correction
- Workflow Guide: ocr-evaluation
- Workflow Guide: adaptation-of-coordinates
- Workflow Guide: format-conversion
- Workflow Guide: generic transformations
- Workflow Guide: dummy processing
- Workflow Guide: archiving
- Workflow Guide: recommended workflows