Custom Gree climate component written in Python3 for Home Assistant. Controls AC's supporting the Gree protocol.
Tested on the following hardware:
- Innova HVAC
- Cooper & Hunter (CH-S12FTXE(WI-FI)-NG)
- AC Pioneer Fortis Series with WI-FI module CS532AE
- AC Gree GWH12ACC-K6DNA1D
- Inventor Life Pro WiFi
- Toyotomi Izuru TRN/TRG-828ZR
- Sinclair ASH-13BIF2
- Sinclair ASH-12BIV
- TOSOT BORA-GWH09AAB
- CASCADE BORA-CWH09AAB
- EWT S-090 GDI-HRFN1, EWT S-120 GDI-HRFN1 (WI-FI module CS532AEH)
- Tadiran Alpha Expert Inverter
- Copmax Air-Air Heatpump GWH12QC-K6DNA5F 3.5kW
- Bulex vivair multisplit units; 20-080MC4NO outdoor unit, 20-025 NWI (2,5 kW) indoor unit, 20-035 NWI (3,5 kW) indoor unit
- Kinghome "Pular" - KW12HQ25SDI (Requires encryption_version=2)
Tested on Home Assistant 2024.5.4.
If you are experiencing issues please be sure to provide details about your device, Home Assistant version and what exactly went wrong.
If your HVAC has already been configured to be controlled remotely by an android app, the encryption key might have changed.
To configure HVAC wifi (without the android app): https://github.com/arthurkrupa/gree-hvac-mqtt-bridge#configuring-hvac-wifi
Sources used:
- https://github.com/tomikaa87/gree-remote
- https://github.com/vpnmaster/homeassistant-custom-components
- https://developers.home-assistant.io/
This component is added to HACS default repository list.
!!! PLEASE NOTE !!!: Skip step 1 if you are using HACS.
-
Copy the custom_components folder to your own hassio /config folder.
-
In the root of your /config folder, create a file called climate.yaml
- platform: gree name: First AC host: <ip of your first AC> port: 7000 mac: '<mac address of your first AC. NOTE: Format can be XX:XX:XX:XX:XX:XX, XX-XX-XX-XX-XX-XX or xxxxxxxxxxxx depending on your model>' target_temp_step: 1 encryption_key: <OPTIONAL: custom encryption key. Integration will try to get key from device if empty> encryption_version: <OPTIONAL: should be set to 2 for V1.21> uid: <some kind of device identifier. NOTE: for some devices this is optional> temp_sensor: <entity id of the EXTERNAL temperature sensor. For example: sensor.bedroom_temperature> lights: <OPTIONAL: input_boolean to switch AC lights mode on/off. For example: input_boolean.first_ac_lights> xfan: <OPTIONAL: input_boolean to switch AC xfan mode on/off. For example: input_boolean.first_ac_xfan> health: <OPTIONAL: input_boolean used to switch the Health option on/off of your first AC. For example: input_boolean.first_ac_health> sleep: <OPTIONAL: input_boolean to switch AC sleep mode on/off. For example: input_boolean.first_ac_sleep> powersave: <OPTIONAL: input_boolean to switch AC powersave mode on/off. For example: input_boolean.first_ac_powersave> eightdegheat: <OPTIONAL: input_boolean used to switch 8 degree heating on/off on your first AC> air: <OPTIONAL: input_boolean used to switch air/scavenging on/off on your first AC> target_temp: <OPTIONAL: input_number used to set the temperature of your first AC> auto_xfan: <OPTIONAL: input_boolean: this feature will always turn on xFan in cool and dry mode to avoid mold & rust created from potential water buildup in the AC> auto_light: <OPTIONAL: input_boolean: this feature will always turn light on when power on and turn light light off when power off automatically> horizontal_swing: <OPTIONAL: boolean (true/false); this feature will enable horizontal swing on devices that have this functionality. This feature replaces presets in the UI anti_direct_blow: <OPTIONAL: input_boolean used to switch Anti Direct Blow feature on devices devices that have this functionality. Until next release, it should be set only when device has this feature. For example: input_boolean.first_ac_anti_direct_blow> light_sensor: <OPTIONAL: input_boolean this feature will enable built-in light sensor. max_online_attempts: <OPTIONAL: integer specifying number of attempts to connect to the device before it goes into the unavailable state disable_available_check: <OPTIONAL: boolean (true/false): if set to true device is always available in Home Assistant, useful for automation, device never goes into an unavailable state - platform: gree name: Second AC host: <ip of your second AC> port: 7000 mac: '<mac address of your second AC. NOTE: Format can be XX:XX:XX:XX:XX:XX or XX-XX-XX-XX-XX-XX depending on your model>' target_temp_step: 1
-
In your configuration.yaml add the following:
climate: !include climate.yaml
-
OPTIONAL: Add info logging to this component (to see if/how it works)
logger: default: error logs: custom_components.gree: debug custom_components.gree.climate: debug
-
OPTIONAL: Provide encryption key if you have it or feel like extracting it.
One way is to pull the sqlite db from android device like described here:
https://stackoverflow.com/questions/9997976/android-pulling-sqlite-database-android-device
adb backup -f ~/backup.ab -noapk com.gree.ewpesmart dd if=data.ab bs=1 skip=24 | python -c "import zlib,sys;sys.stdout.write(zlib.decompress(sys.stdin.read()))" | tar -xvf - sqlite3 data.ab 'select privateKey from db_device_20170503;' # but table name can differ a little bit.
Write it down in climate.yaml
encryption_key: <key>
. -
OPTIONAL: Provide the
uid
parameter (can be sniffed) NOTE: This is not needed for all devices -
OPTIONAL: Provice input_boolean's to set lights, xfan, sleep and powersave mode on/off.
NOTE: Your AC has to support these features for it to be used.
temp_sensor: This attaches an external temperature sensor to your AC. Gree unfortunately doesnt support a "current temperature" on its own.
lights: This switches the backlight of the AC Display on or off
xfan: This dries the AC after being used. This is to avoid nasty smells from usage.
health: The air goes through a filter to "clean the air".
sleep: This will enable a comfortable sleep mode. The AC won't make a lot of noise using this.
powersave: It seems this mode should be an efficient way of approximately reaching the desired temperature (temperatures will vary using this).
eightdegheat: This feature maintains the room temperature steadily at 8°C and prevents the room from freezing by activating the heating operation automatically when nobody is at home over a longer period during severe winter
air: This feature will extract air from the room. This is to remove hot air or nasty smells from the room.
target_temp: You can use a custom input_number entity as the input of the set temperature for this AC. Define the input_number entity in this parameter. This is useful if you want to use dashboards with custom frontend components.
auto_xfan: This feature will always turn on xFan in cool and dry mode to avoid mold & rust created from potential water buildup in the AC
auto_light: This feature will always turn light on when power on and turn light light off when power off automatically