Skip to content

Merten Z wave parameters

Johan Bendz edited this page May 18, 2020 · 3 revisions

Parameter 0: Switching/dimming/shutters dual-surface: Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 4: Switching single-surface Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 44: Doorbell function Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_44_1 and is of type INTEGER.

Parameter 52: LOWER shutter as long as button is pressed Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_52_1 and is of type INTEGER.

Parameter 54: Move shutter single-surface Size: 1. Direction of movement changes after each switching process Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_54_1 and is of type INTEGER.

Parameter 55: RAISE shutter as long as button is pressed Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_55_1 and is of type INTEGER.

Parameter 60: Retrieve/save scene Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_60_1 and is of type INTEGER.

Parameter 176: Staircase timer, byte 1 Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_176_1 and is of type INTEGER.

Parameter 177: Staircase timer, byte 2 Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_177_1 and is of type INTEGER.

Parameter 176: Changeover delay (motor protection. Changeover delay = Input * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_176_1 and is of type INTEGER.

Parameter 177: Raising time (Input 1. Raising time = (256 * Input 1 + Input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_177_1 and is of type INTEGER.

Parameter 178: Raising time (Input 2. Raising time = (256 * Input 1 + Input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_178_1 and is of type INTEGER.

Parameter 179: Lowering time (Input 1. Raising time = (256 * Input 1 + Input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_179_1 and is of type INTEGER.

Parameter 180: Lowering time (Input 2. Raising time = (256 * Input 1 + Input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_180_1 and is of type INTEGER.

Parameter 181: Inclusion of light sensor Size: 1. Values: Auto = 0, Enable = 1, Disable = 2. The manufacturer defined default value is 0. This parameter has the configuration ID config_181_1 and is of type INTEGER.

Parameter 182: Brightness threshold Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_182_1 and is of type INTEGER.

Parameter 183: Additional limit duration (after brief interruption, unsure what this does) Size: 1. Values in the range 0 to 127 may be set. The manufacturer defined default value is 30. This parameter has the configuration ID config_183_1 and is of type INTEGER.

Parameter 183: Reaction threshold for raising shutter (Input 1, Reaction threshold = (256 * Input 1 + input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_183_1 and is of type INTEGER.

Parameter 184: Reaction threshold for raising shutter (Input 2, Reaction threshold = (256 * Input 1 + input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_184_1 and is of type INTEGER.

Parameter 185: Reaction threshold for lowering shutter (Input 2, Reaction threshold = (256 * Input 1 + input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_185_1 and is of type INTEGER.

Parameter 186: Reaction threshold for lowering shutter (Input 2, Reaction threshold = (256 * Input 1 + input 2) * 0.1s) Size: 1. Values in the range 0 to 255 may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_186_1 and is of type INTEGER.

Parameter 196: Dimmer speed Size: 1. Values in the range 0 (fast) to 240 (slow) may be set. The manufacturer defined default value is 0. This parameter has the configuration ID config_196_1 and is of type INTEGER.

Clone this wiki locally