[gree] Add channel for temperature sensor (openhab#8303)
Browse files Browse the repository at this point in the history
Signed-off-by: Clayton Tabone <taboneclayton@gmail.com>
  • Loading branch information
taboneclayton authored and andrewfg committed Oct 8, 2020
1 parent 993e9df commit 27eaf31
Show file tree
Hide file tree
Showing 8 changed files with 116 additions and 65 deletions.
65 changes: 36 additions & 29 deletions bundles/org.openhab.binding.gree/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -19,11 +19,12 @@ No binding configuration is required.

## Thing Configuration

| Channel Name | Type | Description |
|------------------|------------|-----------------------------------------------------------------------------------------------|
| ipAddress | IP Address | IP address of the unit. |
| broadcastAddress | IP Address | Broadcast address being used for discovery, usually derived from the IP interface address. |
| refresh | Integer | Refresh interval in seconds for polling the device status. |
| Channel Name | Type | Description |
|--------------------------|------------|-----------------------------------------------------------------------------------------------|
| ipAddress | IP Address | IP address of the unit. |
| broadcastAddress | IP Address | Broadcast address being used for discovery, usually derived from the IP interface address. |
| refresh | Integer | Refresh interval in seconds for polling the device status. |
| currentTemperatureOffset | Decimal | The offset in Celsius for the current temperature value received from the device. |

The Air Conditioner's IP address is mandatory, all other parameters are optional.
If the broadcast is not set (default) it will be derived from openHAB's network setting (PaperUI:Configuration:System:Network Settings).
Expand All @@ -33,27 +34,28 @@ Only change this if you have a good reason to.

The following channels are supported for fans:

| Channel Name | Item Type | Description |
|---------------|-----------|---------------------------------------------------------------------------------------------------|
| power | Switch | Power on/off the Air Conditioner |
| mode | String | Sets the operating mode of the Air Conditioner |
| | | Mode can be one of auto/cool/eco/dry/fan/heat or on/off |
| | | Check the Air Conditioner's operating manual for supported modes. |
| temperature | Number:Temperature | Sets the desired room temperature |
| air | Switch | Set on/off the Air Conditioner's Air function if applicable to the Air Conditioner model |
| dry | Switch | Set on/off the Air Conditioner's Dry function if applicable to the Air Conditioner model |
| health | Switch | Set on/off the Air Conditioner's Health function if applicable to the Air Conditioner model |
| turbo | Switch | Set on/off the Air Conditioner's Turbo Mode. |
| quiet | String | Set Quiet Mode: off/auto/quiet |
| swingUpDown | Number | Sets the vertical (up..down) swing action on the Air Conditioner, |
| | | OFF: 0, Full Swing: 1, Up: 2, MidUp: 3, Mid: 4, Mid Down: 5, Down : 6 |
| swingLeftRight| Number | Sets the horizontal (left..right) swing action on the Air Conditioner |
| | | OFF: 0, Full Swing: 1, Left: 2, Mid Left: 3, Mid: 4, Mid Right: 5, Right : 6 |
| windspeed | Number | Sets the fan speed on the Air conditioner Auto:0, Low:1, MidLow:2, Mid:3, MidHigh:4, High:5 |
| | | The number of speeds depends on the Air Conditioner model. |
| powersave | Switch | Set on/off the Air Conditioner's Power Saving function if applicable to the Air Conditioner model |
| light | Switch | Enable/disable the front display on the Air Conditioner if applicable to the Air Conditioner model|
| | | Full Swing: 1, Up: 2, MidUp: 3, Mid: 4, Mid Down: 5, Down : 6 |
| Channel Name | Item Type | Description |
|--------------------|-----------|---------------------------------------------------------------------------------------------------|
| power | Switch | Power on/off the Air Conditioner |
| mode | String | Sets the operating mode of the Air Conditioner |
| | | Mode can be one of auto/cool/eco/dry/fan/heat or on/off |
| | | Check the Air Conditioner's operating manual for supported modes. |
| temperature | Number:Temperature | Sets the desired room temperature. |
| currentTemperature | Number:Temperature | Displays the current room temperature. |
| air | Switch | Set on/off the Air Conditioner's Air function if applicable to the Air Conditioner model |
| dry | Switch | Set on/off the Air Conditioner's Dry function if applicable to the Air Conditioner model |
| health | Switch | Set on/off the Air Conditioner's Health function if applicable to the Air Conditioner model |
| turbo | Switch | Set on/off the Air Conditioner's Turbo Mode. |
| quiet | String | Set Quiet Mode: off/auto/quiet |
| swingUpDown | Number | Sets the vertical (up..down) swing action on the Air Conditioner, |
| | | OFF: 0, Full Swing: 1, Up: 2, MidUp: 3, Mid: 4, Mid Down: 5, Down : 6 |
| swingLeftRight | Number | Sets the horizontal (left..right) swing action on the Air Conditioner |
| | | OFF: 0, Full Swing: 1, Left: 2, Mid Left: 3, Mid: 4, Mid Right: 5, Right : 6 |
| windspeed | Number | Sets the fan speed on the Air conditioner Auto:0, Low:1, MidLow:2, Mid:3, MidHigh:4, High:5 |
| | | The number of speeds depends on the Air Conditioner model. |
| powersave | Switch | Set on/off the Air Conditioner's Power Saving function if applicable to the Air Conditioner model |
| light | Switch | Enable/disable the front display on the Air Conditioner if applicable to the Air Conditioner model|
| | | Full Swing: 1, Up: 2, MidUp: 3, Mid: 4, Mid Down: 5, Down : 6 |


When changing mode, the air conditioner will be turned on unless "off" is selected.
Expand All @@ -73,7 +75,8 @@ Switch AirconPower { channel="gree:airconditioner:a1234561:powe
String AirconMode { channel="gree:airconditioner:a1234561:mode" }
Switch AirconTurbo { channel="gree:airconditioner:a1234561:turbo" }
Switch AirconLight { channel="gree:airconditioner:a1234561:light" }
Number AirconTemp "Temperature [%.1f °C]" {channel="gree:airconditioner:a1234561:temperature" }
Number AirconTargetTemp "Target Temperature [%.1f °C]" {channel="gree:airconditioner:a1234561:temperature" }
Number AirconCurrentTemp "Current Temperature [%.1f °C]" {channel="gree:airconditioner:a1234561:currentTemperature" }
Number AirconSwingVertical { channel="gree:airconditioner:a1234561:swingUpDown" }
Number AirconSwingHorizontal { channel="gree:airconditioner:a1234561:swingLeftRight" }
Number AirconFanSpeed { channel="gree:airconditioner:a1234561:windspeed" }
Expand All @@ -91,7 +94,11 @@ This is an example of how to set up your sitemap.
Frame label="Controls"
{
Switch item=AirconMode label="Mode" mappings=["auto"="Auto", "cool"="Cool", "eco"="Eco", "dry"="Dry", "fan"="Fan", "turbo"="Turbo", "heat"="Heat", "on"="ON", "off"="OFF"]
Setpoint item=AirconTemp label="Set temperature" icon=temperature minValue=16 maxValue=30 step=1
Setpoint item=AirconTargetTemp label="Set target temperature" icon=temperature minValue=16 maxValue=30 step=1
}
Frame label="Current Temperature"
{
Text item=AirconCurrentTemp label="Current temperature [%.1f °C]" icon="temperature"
}
Frame label="Fan Speed"
{
Expand Down Expand Up @@ -124,7 +131,7 @@ Group Gree_Modechannel "Gree" { ga="Thermostat" } //
Switch GreeAirConditioner_Power "Aircon" {channel="gree:airconditioner:a1234561:power", ga="Switch"}
String GreeAirConditioner_Mode "Aircon Mode" {channel="gree:airconditioner:a1234561:mode", ga="thermostatMode"}
Number GreeAirConditioner_Temp "Aircon Temperature" {channel="gree:airconditioner:a1234561:temperature}
Switch GreeAirConditioner_Lightl "Light" {channel="gree:airconditioner:a1234561:light"}
Switch GreeAirConditioner_Light "Light" {channel="gree:airconditioner:a1234561:light"}
```

**Rules**
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -45,7 +45,8 @@ public class GreeBindingConstants {
public static final String MODE_CHANNEL = "mode";
public static final String TURBO_CHANNEL = "turbo";
public static final String LIGHT_CHANNEL = "light";
public static final String TEMP_CHANNEL = "temperature";
public static final String TARGET_TEMP_CHANNEL = "temperature";
public static final String CURRENT_TEMP_CHANNEL = "currentTemperature";
public static final String SWINGUD_CHANNEL = "swingUpDown";
public static final String SWINGLR_CHANNEL = "swingLeftRight";
public static final String WINDSPEED_CHANNEL = "windspeed";
Expand Down Expand Up @@ -137,6 +138,7 @@ public class GreeBindingConstants {
public static final String GREE_PROP_HEAT = "StHt";
public static final String GREE_PROP_HEATCOOL = "HeatCoolType";
public static final String GREE_PROP_NOISESET = "NoiseSet";
public static final String GREE_PROP_CURRENT_TEMP_SENSOR = "TemSen";

// Temperatur types and min/max ranges
public static final int TEMP_UNIT_CELSIUS = 0;
Expand All @@ -159,4 +161,15 @@ public class GreeBindingConstants {
public static final int REFRESH_INTERVAL_SEC = 5;

public static final int DIGITS_TEMP = 1;

/**
* The internal offset for the temperature sensor which is set to a constant of -40 degrees Celsius. GREE
* airconditioners usually return a value from the temperature sensor which is offset by +40 degrees Celsius. The
* temperature value shown on the device LCD display should match the value shown by this binding when the config
* parameter currentTemperatureOffset is set to 0.
*
* @See https://github.com/tomikaa87/gree-remote#getting-the-current-temperature-reading-from-the-internal-sensor
* for more details.
*/
public static final double INTERNAL_TEMP_SENSOR_OFFSET = -40.0;
}
Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,8 @@
*/
package org.openhab.binding.gree.internal;

import java.math.BigDecimal;

import org.eclipse.jdt.annotation.NonNullByDefault;

/**
Expand All @@ -25,9 +27,15 @@ public class GreeConfiguration {
public String ipAddress = "";
public String broadcastAddress = "";
public int refresh = 60;
/**
* The currentTemperatureOffset is configureable in case the user wants to offset this temperature for calibration
* of the temperature sensor.
*/
public BigDecimal currentTemperatureOffset = new BigDecimal(0.0);

@Override
public String toString() {
return "Config: ipAddress=" + ipAddress + ", broadcastAddress=" + broadcastAddress + ", refresh=" + refresh;
return "Config: ipAddress=" + ipAddress + ", broadcastAddress=" + broadcastAddress + ", refresh=" + refresh
+ ", currentTemperatureOffset=" + currentTemperatureOffset;
}
}
Original file line number Diff line number Diff line change
Expand Up @@ -105,6 +105,7 @@ public void getDeviceStatus(DatagramSocket clientSocket) throws GreeException {
columns.add(GREE_PROP_TEMPREC);
columns.add(GREE_PROP_PWR_SAVING);
columns.add(GREE_PROP_NOISESET);
columns.add(GREE_PROP_CURRENT_TEMP_SENSOR);

// Convert the parameter map values to arrays
String[] colArray = columns.toArray(new String[0]);
Expand Down Expand Up @@ -231,10 +232,6 @@ public void setQuietMode(DatagramSocket clientSocket, int value) throws GreeExce
setCommandValue(clientSocket, GREE_PROP_QUIET, value, 0, 2);
}

public int getDeviceTurbo() {
return getIntStatusVal(GREE_PROP_TURBO);
}

public void setDeviceLight(DatagramSocket clientSocket, int value) throws GreeException {
setCommandValue(clientSocket, GREE_PROP_LIGHT, value);
}
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -153,7 +153,7 @@ public void handleCommand(ChannelUID channelUID, Command command) {
case LIGHT_CHANNEL:
device.setDeviceLight(socket, getOnOff(command));
break;
case TEMP_CHANNEL:
case TARGET_TEMP_CHANNEL:
// Set value, read back effective one and update channel
// e.g. 22.5C will result in 22.0, because the AC doesn't support half-steps for C
device.setDeviceTempSet(socket, convertTemp(command));
Expand Down Expand Up @@ -405,8 +405,11 @@ private void publishChannel(ChannelUID channelUID) {
case LIGHT_CHANNEL:
state = updateOnOff(GREE_PROP_LIGHT);
break;
case TEMP_CHANNEL:
state = updateTemp();
case TARGET_TEMP_CHANNEL:
state = updateTargetTemp();
break;
case CURRENT_TEMP_CHANNEL:
state = updateCurrentTemp();
break;
case SWINGUD_CHANNEL:
state = updateNumber(GREE_PROP_SWINGUPDOWN);
Expand Down Expand Up @@ -505,7 +508,7 @@ private void publishChannel(ChannelUID channelUID) {
return null;
}

private @Nullable State updateTemp() throws GreeException {
private @Nullable State updateTargetTemp() throws GreeException {
if (device.hasStatusValChanged(GREE_PROP_SETTEMP) || device.hasStatusValChanged(GREE_PROP_TEMPUNIT)) {
int unit = device.getIntStatusVal(GREE_PROP_TEMPUNIT);
return toQuantityType(device.getIntStatusVal(GREE_PROP_SETTEMP), DIGITS_TEMP,
Expand All @@ -514,6 +517,14 @@ private void publishChannel(ChannelUID channelUID) {
return null;
}

private @Nullable State updateCurrentTemp() throws GreeException {
if (device.hasStatusValChanged(GREE_PROP_CURRENT_TEMP_SENSOR)) {
return new DecimalType(device.getIntStatusVal(GREE_PROP_CURRENT_TEMP_SENSOR) + INTERNAL_TEMP_SENSOR_OFFSET
+ config.currentTemperatureOffset.doubleValue());
}
return null;
}

private String logInfo(String msgKey, Object... arg) {
String message = messages.get(msgKey, arg);
logger.info("{}: {}", thingId, message);
Expand All @@ -525,7 +536,7 @@ public static QuantityType<?> toQuantityType(Number value, int digits, Unit<?> u
return new QuantityType<>(bd.setScale(digits, BigDecimal.ROUND_HALF_EVEN), unit);
}

private void stopRefrestTask() {
private void stopRefreshTask() {
forceRefresh = false;
if (refreshTask == null) {
return;
Expand All @@ -544,7 +555,7 @@ public void dispose() {
clientSocket.get().close();
clientSocket = Optional.empty();
}
stopRefrestTask();
stopRefreshTask();
if (initializeFuture != null) {
initializeFuture.cancel(true);
}
Expand Down