Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

New feature for MiElHVAC #22290

Merged
merged 6 commits into from
Oct 14, 2024
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
74 changes: 60 additions & 14 deletions tasmota/tasmota_xdrv_driver/xdrv_44_miel_hvac.ino
Original file line number Diff line number Diff line change
Expand Up @@ -91,8 +91,14 @@ struct miel_hvac_data_roomtemp {

struct miel_hvac_data_status {
uint8_t _pad1[2];
uint8_t _pad2[1];
uint8_t compressor;
uint8_t operation;
#define MIEL_HVAC_STATUS_COMPRESSOR_OFF 0x00
#define MIEL_HVAC_STATUS_COMPRESSOR_ON 0x01
uint8_t operationpower;
uint8_t operationpower1;
uint8_t operationenergy;
uint8_t operationenergy1;
};

struct miel_hvac_data {
Expand Down Expand Up @@ -130,6 +136,12 @@ CTASSERT(offsetof(struct miel_hvac_data, data.settings.airdirection) == 14);
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.temp) == 3);
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.temp05) == 6);

CTASSERT(offsetof(struct miel_hvac_data, data.status.compressor) == 4);
CTASSERT(offsetof(struct miel_hvac_data, data.status.operationpower) == 5);
CTASSERT(offsetof(struct miel_hvac_data, data.status.operationpower1) == 6);
CTASSERT(offsetof(struct miel_hvac_data, data.status.operationenergy) == 7);
CTASSERT(offsetof(struct miel_hvac_data, data.status.operationenergy1) == 8);

/* to hvac */

#define MIEL_HVAC_H_TYPE_CONNECT 0x5a
Expand Down Expand Up @@ -206,7 +218,7 @@ struct miel_hvac_msg_update {
uint8_t _pad1[4];
uint8_t widevane;
#define MIEL_HVAC_UPDATE_WIDEVANE_MASK 0x0f
#define MIEL_HVAC_UPDATE_WIDEVANE_ISEE 0x00
#define MIEL_HVAC_UPDATE_WIDEVANE_AUTO 0x00
#define MIEL_HVAC_UPDATE_WIDEVANE_LL 0x01
#define MIEL_HVAC_UPDATE_WIDEVANE_L 0x02
#define MIEL_HVAC_UPDATE_WIDEVANE_C 0x03
Expand Down Expand Up @@ -304,6 +316,11 @@ struct miel_hvac_map {
const char *name;
};

static const struct miel_hvac_map miel_hvac_power_map[] = {
{ MIEL_HVAC_UPDATE_POWER_OFF, "off" },
{ MIEL_HVAC_UPDATE_POWER_ON, "on" },
};

static const struct miel_hvac_map miel_hvac_mode_map[] = {
{ MIEL_HVAC_UPDATE_MODE_HEAT, "heat" },
{ MIEL_HVAC_UPDATE_MODE_DRY, "dry" },
Expand Down Expand Up @@ -335,7 +352,7 @@ static const struct miel_hvac_map miel_hvac_vane_map[] = {
};

static const struct miel_hvac_map miel_hvac_widevane_map[] = {
{ MIEL_HVAC_UPDATE_WIDEVANE_ISEE, "isee" },
{ MIEL_HVAC_UPDATE_WIDEVANE_AUTO, "auto" },
{ MIEL_HVAC_UPDATE_WIDEVANE_LL, "left" },
{ MIEL_HVAC_UPDATE_WIDEVANE_L, "left_middle" },
{ MIEL_HVAC_UPDATE_WIDEVANE_C, "center" },
Expand All @@ -362,6 +379,11 @@ static const struct miel_hvac_map miel_hvac_airdirection_map[] = {
{ MIEL_HVAC_UPDATE_AIRDIRECTION_DIRECT, "direct" },
};

static const struct miel_hvac_map miel_hvac_compressor_map[] = {
{ MIEL_HVAC_STATUS_COMPRESSOR_OFF, "off" },
{ MIEL_HVAC_STATUS_COMPRESSOR_ON, "on" },
};

enum miel_hvac_parser_state {
MIEL_HVAC_P_START,
MIEL_HVAC_P_TYPE,
Expand Down Expand Up @@ -997,8 +1019,12 @@ miel_hvac_publish_settings(struct miel_hvac_softc *sc)
const char *name;
const char *name_swing_h;

Response_P(PSTR("{\"" D_JSON_IRHVAC_POWER "\":\"%s\""),
set->power ? "ON" : "OFF");
name = miel_hvac_map_byval(set->power,
miel_hvac_power_map, nitems(miel_hvac_power_map));
if (name != NULL) {
Response_P(PSTR("{\"" D_JSON_IRHVAC_POWER "\":\"%s\""),
name);
}

name = miel_hvac_map_byval( set->mode &
MIEL_HVAC_SETTINGS_MODE_MASK,
Expand Down Expand Up @@ -1046,7 +1072,7 @@ miel_hvac_publish_settings(struct miel_hvac_softc *sc)
miel_hvac_airdirection_map, nitems(miel_hvac_airdirection_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"AirDirection\":\"%s\""),
name_swing_h == "isee" ? name : "OFF");
name_swing_h == "auto" ? name : "OFF");
}

name = miel_hvac_map_byval(set->prohibit,
Expand Down Expand Up @@ -1236,8 +1262,13 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
const char *name_swing_h;

ResponseAppend_P(PSTR("," "\"MiElHVAC\":{"));
ResponseAppend_P(PSTR("\"Power\":\"%s\""),
set->power ? "ON" : "OFF");

name = miel_hvac_map_byval(set->power,
miel_hvac_power_map, nitems(miel_hvac_power_map));
if (name != NULL) {
ResponseAppend_P(PSTR("\"Power\":\"%s\""),
name);
}

name = miel_hvac_map_byval( set->mode &
MIEL_HVAC_SETTINGS_MODE_MASK,
Expand Down Expand Up @@ -1283,7 +1314,7 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
miel_hvac_airdirection_map, nitems(miel_hvac_airdirection_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"AirDirection\":\"%s\""),
name_swing_h == "isee" ? name : "OFF");
name_swing_h == "auto" ? name : "off");
}

name = miel_hvac_map_byval(set->prohibit,
Expand Down Expand Up @@ -1317,13 +1348,28 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
}

if (sc->sc_status.type != 0) {
const struct miel_hvac_data_status *s =
const struct miel_hvac_data_status *status =
&sc->sc_status.data.status;

ResponseAppend_P(PSTR(",\"Operation\":\"%s\""),
s->operation ? "ON" : "OFF");
ResponseAppend_P(PSTR(",\"Compressor\":\"%s\""),
s->compressor ? "ON" : "OFF");
name = miel_hvac_map_byval(status->compressor,
miel_hvac_compressor_map, nitems(miel_hvac_compressor_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"Compressor\":\"%s\""),
name);
}

uint16_t combined_power = ((uint16_t)status->operationpower << 8) | (uint16_t)status->operationpower1;
char operationpower[33];
dtostrfd((float)combined_power, 0, operationpower);
ResponseAppend_P(PSTR(",\"OperationPower\":\"%s\""),
operationpower);

uint16_t combined_energy = ((uint16_t)status->operationenergy << 8) | (uint16_t)status->operationenergy1;
float operationenergy_in_kWh = (float)combined_energy / 10.0;
char operationenergy[33];
dtostrfd((float)operationenergy_in_kWh, 1, operationenergy);
ResponseAppend_P(PSTR(",\"OperationEnergy\":\"%s\""),
operationenergy);
}

if (sc->sc_temp.type != 0) {