Skip to content
Arjen Hiemstra edited this page Sep 13, 2023 · 44 revisions

Welcome to the ithowifi wiki!

To buy visit this page https://www.nrgwatch.nl/ (Dutch) or https://www.tindie.com (English).

This Wiki covers the installation and configuration of the add-on for both the CVE and non-CVE units, integration with home automation software and more.

Note: the add-on hardware and software is the result of reverse engineering and endless hours of testing and debugging. It is not endorsed or supported by Itho Daalderop.

The add-on covers various use-cases so consider these first before obtaining it.

With or without CC1101 module?

When ordering add-on, you need to decide on CC1101 or not. The add-on works fine without CC1101 but if you want to link existing remotes and monitor their status, you can use the CC1101 transceiver to pair the existing remotes and read its commands and - if applicable - CO2 values (itho RFT-CO2) and Humidity/Temperature values (itho RFT-RV). For HRU300 devices the CC1101 module is needed to control the speed of the fan. This is due to the limited support for the I2C protocol on these devices.

Supported devices

The following Itho devices are supported or have been tested by the community. Use this table to select the right add-on.

Device Type Add-on Comments
CVE ECO 2 Fan CVE This unit is also sold by the
brand 'Heatrae Sadia' in the UK
CVE ECO RFT (SE/SP, HE/HP) Fan CVE
CVE-S ECO (SE/SP, HE/HP) Fan CVE
CVE-S OPTIMA inside
(with built-in CO2 sensor)
Fan CVE CO2 sensor only usable when extra long
headers are used on the add-on
CVE-S OPTIMA package
(with external CO2 sensor)
Fan CVE To readout the CO2 sensor the CC1101
module is needed
HRU 200 ECO Fan CVE Also sold as 'Elektrodesign EHR 140 Akor BP'
and 'Heatrae Sadia Advance Plus'
DemandFlow Fan non-CVE Readout values and change settings only
QualityFlow Fan non-CVE Readout values and change settings only
HRU-300 Heat Exchanger non-CVE Adapter board and CC1101 needed for full control
HRU-350 Heat Exchanger non-CVE WTW
HRU ECO Heat Exchanger non-CVE WTW
WPU 5G Heat pump non-CVE Readout values and change settings only
AutoTemp Floor heating distributor non-CVE Readout values and change settings only

Non working devices

The main print below is from a CVE ECO 2E article number 545-5020 version 110-0010-002 and doesn't have the 2x4 pins connector so the CVE addon won't work.

Main Print 1 Main Print 2
The backside of the RF print.
Main Print 3

Installation

The add-on hardware and installation steps differs per unit type.

  • Addon for CVE
    This applies to the Itho Daalderop CVE-S and related units.

  • Addon for non-CVE
    This applies to DemandFlow, QualityFlow and HRU-350 and supported WTW units.

  • Addon for WPU Heat Pump
    This uses the non-CVE add-on but applies to Itho Daalderop WPU Heat Pump like 5G.

Remotes and CO2 sensors

Integration

Once the CVE or non-CVE add-on is installed, automation is a logical next step. Use either the Web API or MQTT for the basics.

Guidance for modern home automation systems Home Assistant, Node-RED, HomeBridge and Domoticz is covered here

Issues?

See here how to report issues via GitHub.

On Gathering of Tweakers (Dutch only) forum, there is active thread with users of the add-on. See here: https://gathering.tweakers.net/forum/list_messages/1976492/0