#Helios Binding for Modbus TCP#
##Configuration and Deployment##
Configuration in openhab.cfg:
############################### Helios Binding ########################################
#
helios:host=<ip-address>
#helios:port=502
#helios:unit=180
#helios:startAddress=1
Folder _release
contains the JAR of the actual plugin. It also contains sample configuration files (items, sitemap, ...) based on my personal configuration.
##Binding##
Bindings are specified based on the following simple syntax:
{ helios="<variable-name>" }
See the following table for the supported variables:
Description | Access | Variable | Min Value | Max Value |
---|---|---|---|---|
article_description | RW | v00000 | - | - |
ref_no | RW | v00001 | - | - |
mac_address | R | v00002 | - | - |
language | RW | v00003 | - | - |
date | RW | v00004 | - | - |
time | RW | v00005 | - | - |
summer_winter | RW | v00006 | - | - |
auto_sw_update | RW | v00007 | - | - |
access_helios_portal | RW | v00008 | - | - |
volt_fan_s1_ea | RW | v00012 | 1.6 | 10.0 |
volt_fan_s1_sa | RW | v00013 | 1.6 | 10.0 |
volt_fan_s2_ea | RW | v00014 | 1.6 | 10.0 |
volt_fan_s2_sa | RW | v00015 | 1.6 | 10.0 |
volt_fan_s3_ea | RW | v00016 | 1.6 | 10.0 |
volt_fan_s3_sa | RW | v00017 | 1.6 | 10.0 |
volt_fan_s4_ea | RW | v00018 | 1.6 | 10.0 |
volt_fan_s4_sa | RW | v00019 | 1.6 | 10.0 |
min_fan_stage | RW | v00020 | 0 | 1 |
kwl_be | RW | v00021 | 0 | 1 |
kwl_bec | RW | v00022 | 0 | 1 |
unit_config | RW | v00023 | 0 | 1 |
pre-heater_status | RW | v00024 | 0 | 1 |
kwl_ftf_config0 | RW | v00025 | 1 | 3 |
kwl_ftf_config1 | RW | v00026 | 1 | 3 |
kwl_ftf_config2 | RW | v00027 | 1 | 3 |
kwl_ftf_config3 | RW | v00028 | 1 | 3 |
kwl_ftf_config4 | RW | v00029 | 1 | 3 |
kwl_ftf_config5 | RW | v00030 | 1 | 3 |
kwl_ftf_config6 | RW | v00031 | 1 | 3 |
kwl_ftf_config7 | RW | v00032 | 1 | 3 |
humidity_control_status | RW | v00033 | 0 | 2 |
humidity_control_set_value | RW | v00034 | 20 | 80 |
humidity_control_steps | RW | v00035 | 5 | 20 |
humidity_control_stop_time | RW | v00036 | 0 | 24 |
co2_control_status | RW | v00037 | 0 | 2 |
co2_control_set_value | RW | v00038 | 300 | 2000 |
co2_control_steps | RW | v00039 | 50 | 400 |
voc_control_status | RW | v00040 | 0 | 2 |
voc_control_set_value | RW | v00041 | 300 | 2000 |
voc_control_steps | RW | v00042 | 50 | 400 |
comfort_temp | RW | v00043 | 10 | 25 |
time_zone_diff_to_gmt | RW | v00051 | -12 | 14 |
date_format | RW | v00052 | 0 | 2 |
heat_exchanger_type | RW | v00053 | 0 | 3 |
party-mode_duration | RW | v00091 | 5 | 180 |
party-mode_fan_stage | RW | v00092 | 0 | 4 |
party-mode_remaining_time | R | v00093 | 0 | 180 |
party-mode | RW | v00094 | 0 | 1 |
standby-mode_duration | RW | v00096 | 5 | 180 |
standby-mode_fan_stage | RW | v00097 | 0 | 4 |
standby-mode_remaining_time | R | v00098 | 0 | 180 |
standby-mode | RW | v00099 | 0 | 1 |
operating_mode | RW | v00101 | 0 | 1 |
fan_stage | RW | v00102 | 0 | 4 |
percentage_fan_stage | R | v00103 | 0 | 100 |
temperature_outside_air | R | v00104 | -27 | 9998 |
temperature_supply_air | R | v00105 | -27 | 9998 |
temperature_outgoing_air | R | v00106 | -27 | 9998 |
temperature_extract_air | R | v00107 | -27 | 9998 |
vhz_duct_sensor | R | v00108 | -27 | 9998 |
nhz_return_sensor | R | v00110 | -27 | 9998 |
ext_sensor_kwl-ftf_humid_1 | R | v00111 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_2 | R | v00112 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_3 | R | v00113 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_4 | R | v00114 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_5 | R | v00115 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_6 | R | v00116 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_7 | R | v00117 | 0 | 9998 |
ext_sensor_kwl-ftf_humid_8 | R | v00118 | 0 | 9998 |
ext_sensor_kwl-ftf_temp_1 | R | v00119 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_2 | R | v00120 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_3 | R | v00121 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_4 | R | v00122 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_5 | R | v00123 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_6 | R | v00124 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_7 | R | v00125 | -27 | 9998 |
ext_sensor_kwl-ftf_temp_8 | R | v00126 | -27 | 9998 |
ext_sensor_kwl-co2_1 | R | v00128 | 0 | 9998 |
ext_sensor_kwl-co2_2 | R | v00129 | 0 | 9998 |
ext_sensor_kwl-co2_3 | R | v00130 | 0 | 9998 |
ext_sensor_kwl-co2_4 | R | v00131 | 0 | 9998 |
ext_sensor_kwl-co2_5 | R | v00132 | 0 | 9998 |
ext_sensor_kwl-co2_6 | R | v00133 | 0 | 9998 |
ext_sensor_kwl-co2_7 | R | v00134 | 0 | 9998 |
ext_sensor_kwl-co2_8 | R | v00135 | 0 | 9998 |
ext_sensor_kwl-voc_1 | R | v00136 | 0 | 9998 |
ext_sensor_kwl-voc_2 | R | v00137 | 0 | 9998 |
ext_sensor_kwl-voc_3 | R | v00138 | 0 | 9998 |
ext_sensor_kwl-voc_4 | R | v00139 | 0 | 9998 |
ext_sensor_kwl-voc_5 | R | v00140 | 0 | 9998 |
ext_sensor_kwl-voc_6 | R | v00141 | 0 | 9998 |
ext_sensor_kwl-voc_7 | R | v00142 | 0 | 9998 |
ext_sensor_kwl-voc_8 | R | v00143 | 0 | 9998 |
nhz_duct_sensor | R | v00146 | -27 | 9998 |
week_profile_nhz | RW | v00201 | 0 | 6 |
ser_no | RW | v00303 | - | - |
prod_code | RW | v00304 | - | - |
supply_air_rpm | R | v00348 | 0 | 9999 |
extract_air_rpm | R | v00349 | 0 | 9999 |
logout | W | v00403 | 1 | 1 |
holiday_programme | RW | v00601 | 0 | 2 |
holiday_programme_fan_stage | RW | v00602 | 1 | 4 |
holiday_programme_start | RW | v00603 | - | - |
holiday_programme_end | RW | v00604 | - | - |
holiday_programme_interval | RW | v00605 | 1 | 24 |
holiday_programme_activation_time | RW | v00606 | 5 | 300 |
vhz_type | RW | v01010 | 1 | 4 |
function_type_kwl-em | RW | v01017 | 1 | 2 |
run-on_time_vhz_nhz | RW | v01019 | 60 | 120 |
external_contact | RW | v01020 | 1 | 6 |
error_output_function | RW | v01021 | 1 | 2 |
filter_change | RW | v01031 | 0 | 1 |
filter_change_interval | RW | v01032 | 0 | 12 |
filter_change_remaining_time | R | v01033 | 2 | 4294967295 |
bypass_room_temp | RW | v01035 | 10 | 40 |
bypass_min_outside_temp | RW | v01036 | 5 | 20 |
factory_setting_wzu | RW | v01037 | 3 | 10 |
factory_reset | RW | v01041 | 1 | 1 |
supply_air_fan_stage | RW | v01050 | 1 | 4 |
extract_air_fan_stage | RW | v01051 | 1 | 4 |
fan_stages_stepped_range0-2 | RW | v01061 | 0 | 2 |
fan_stages_stepped_range2-4 | RW | v01062 | 0 | 2 |
fan_stages_stepped_range4-6 | RW | v01063 | 0 | 2 |
fan_stages_stepped_range6-8 | RW | v01064 | 0 | 2 |
fan_stages_stepped_range8-10 | RW | v01065 | 0 | 2 |
offset_extract_air | RW | v01066 | - | - |
fan_stages_stepped_vs_1-10v | RW | v01068 | 0 | 1 |
sensor_name_humidity+temp1 | RW | v01071 | - | - |
sensor_name_humidity+temp2 | RW | v01072 | - | - |
sensor_name_humidity+temp3 | RW | v01073 | - | - |
sensor_name_humidity+temp4 | RW | v01074 | - | - |
sensor_name_humidity+temp5 | RW | v01075 | - | - |
sensor_name_humidity+temp6 | RW | v01076 | - | - |
sensor_name_humidity+temp7 | RW | v01077 | - | - |
sensor_name_humidity+temp8 | RW | v01078 | - | - |
sensor_name_co21 | RW | v01081 | - | - |
sensor_name_co22 | RW | v01082 | - | - |
sensor_name_co23 | RW | v01083 | - | - |
sensor_name_co24 | RW | v01084 | - | - |
sensor_name_co25 | RW | v01085 | - | - |
sensor_name_co26 | RW | v01086 | - | - |
sensor_name_co27 | RW | v01087 | - | - |
sensor_name_co28 | RW | v01088 | - | - |
sensor_name_voc1 | RW | v01091 | - | - |
sensor_name_voc2 | RW | v01092 | - | - |
sensor_name_voc3 | RW | v01093 | - | - |
sensor_name_voc4 | RW | v01094 | - | - |
sensor_name_voc5 | RW | v01095 | - | - |
sensor_name_voc6 | RW | v01096 | - | - |
sensor_name_voc7 | RW | v01097 | - | - |
sensor_name_voc8 | RW | v01098 | - | - |
sw_version | R | v01101 | 0.0 | 99.99 |
operating_hours_supply_air_vent | R | v01103 | 0 | 4294967295 |
operating_hours_extract_air_vent | R | v01104 | 0 | 4294967295 |
operating_hours_vhz | R | v01105 | 0 | 4294967295 |
operating_hours_nhz | R | v01106 | 0 | 4294967295 |
output_power_vhz_percent | R | v01108 | 0 | 4294967295 |
output_power_nhz_percent | R | v01109 | 0 | 4294967295 |
reset_flag | R | v01120 | 1 | 1 |
errors | R | v01123 | 0 | 4294967295 |
warnings | R | v01124 | 0 | 255 |
infos | R | v01125 | 0 | 255 |
number_of_errors | R | v01300 | 0 | 32 |
number_of_warnings | R | v01301 | 0 | 8 |
number_of_infos | R | v01302 | 0 | 8 |
errors_string | R | v01303 | - | - |
warnings_string | R | v01304 | - | - |
infos_string | R | v01305 | - | - |
status_flags | R | v01306 | - | - |
global_manual_web-update | RW | v02013 | 1 | 1 |
portal_latest_error | R | v02014 | 1 | 255 |
clear_error | W | v02015 | 1 | 1 |
kw_ftf_config1 | R | v02020 | 0 | 1 |
kw_ftf_config2 | R | v02021 | 0 | 1 |
kw_ftf_config3 | R | v02022 | 0 | 1 |
kw_ftf_config4 | R | v02023 | 0 | 1 |
kw_ftf_config5 | R | v02024 | 0 | 1 |
kw_ftf_config6 | R | v02025 | 0 | 1 |
kw_ftf_config7 | R | v02026 | 0 | 1 |
kw_ftf_config8 | R | v02027 | 0 | 1 |
##Implementation## The implementation is based on the Helios Modbus Gateway TCP/IP specification.