fix for BRP069A81. WARNING: breaking change for other types
Browse files Browse the repository at this point in the history
  • Loading branch information
Mich-b committed Aug 6, 2022
1 parent bfa0bcf commit 1ffce1e
Showing 1 changed file with 10 additions and 14 deletions.
24 changes: 10 additions & 14 deletions index.js
Original file line number Diff line number Diff line change
Expand Up @@ -366,7 +366,7 @@ Daikin.prototype = {
const responseValues = this.parseResponse(body);
this.log.debug('getActive: Power is: %s, Mode is %s', responseValues.pow, responseValues.mode);
let HomeKitState = '0';
if (responseValues.mode === '6' || responseValues.mode === '2' || responseValues.mode === '1') // If AC is in Fan-mode, or an Humidity-mode then show AC OFF in HomeKit
if (responseValues.mode === '6' || responseValues.mode === '2') // If AC is in Fan-mode, or an Humidity-mode then show AC OFF in HomeKit
HomeKitState = '0';
else
if (responseValues.pow === '1')
Expand All @@ -391,7 +391,7 @@ Daikin.prototype = {
const responseValues = this.parseResponse(body);
this.log.info('setActive: Power is %s, Mode is %s. Going to change power to %s.', responseValues.pow, responseValues.mode, power);
let query = body.replace(/,/g, '&').replace(/pow=[01]/, `pow=${power}`);
if (responseValues.mode === '6' || responseValues.mode === '2' || responseValues.mode === '1' || responseValues.mode === '0') {// If AC is in Fan-mode, or an Humidity-mode then use the default mode.
if (responseValues.mode === '6' || responseValues.mode === '2' ) {// If AC is in Fan-mode, or an Humidity-mode then use the default mode.
switch (this.defaultMode) {
case '1': // Auto
this.log.warn('Auto');
Expand Down Expand Up @@ -488,16 +488,15 @@ Daikin.prototype = {
let status = Characteristic.CurrentHeaterCoolerState.INACTIVE;
if (responseValues.pow === '1') {
switch (responseValues.mode) {
case '0': // Auto
case '1': // humidification
case '2': // dehumidification
case '1': // Auto
case '2': // Dry
case '6': // FAN-Mode
status = Characteristic.CurrentHeaterCoolerState.IDLE;
break;
case '3':
case '3': //Cool
status = Characteristic.CurrentHeaterCoolerState.COOLING;
break;
case '4':
case '4': //Heat
status = Characteristic.CurrentHeaterCoolerState.HEATING;
break;
default:
Expand Down Expand Up @@ -527,13 +526,10 @@ Daikin.prototype = {
let status = Characteristic.TargetHeaterCoolerState.AUTO;
if (responseValues.pow === '1') {
switch (responseValues.mode) {
case '0': // automatic
case '1': // automatic
status = Characteristic.TargetHeaterCoolerState.AUTO;
break;
case '1': // humidification
status = Characteristic.TargetHeaterCoolerState.AUTO;
break;
case '2': // dehumidification
case '2': // dry
status = Characteristic.TargetHeaterCoolerState.AUTO;
break;
case '3': // cool
Expand All @@ -542,7 +538,7 @@ Daikin.prototype = {
case '4': // heat
status = Characteristic.TargetHeaterCoolerState.HEAT;
break;
case '6': // AUTO or FAN
case '6': // FAN
status = Characteristic.TargetHeaterCoolerState.AUTO;
break;
default:
Expand Down Expand Up @@ -573,7 +569,7 @@ Daikin.prototype = {
switch (state) {
case Characteristic.TargetHeaterCoolerState.AUTO:
this.log.info('HomeKit requested the AC to operate in AUTO mode.');
mode = 0;
mode = 1;
break;
case Characteristic.TargetHeaterCoolerState.COOL:
this.log.info('HomeKit requested the AC to operate in COOL mode.');
Expand Down

2 comments on commit 1ffce1e

@HelderCardoso
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Is it just for this model?

@Mich-b
Copy link
Author

@Mich-b Mich-b commented on 1ffce1e Aug 8, 2022

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I’m afraid so, see #257

Please sign in to comment.