80X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting #12190
80X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting #12190
Conversation
…h incorrect 16 samples flag reporting
A new Pull Request was created by @barvic for CMSSW_8_0_X. 80X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting It involves the following packages: EventFilter/CSCRawToDigi @cmsbuild, @cvuosalo, @slava77 can you please review it and eventually sign? Thanks. |
@cmsbuild please test |
The tests are being triggered in jenkins. |
The jenkins tests job failed, please try again. |
+1 Bug fix to handle rare cases of CSC CFEB data corruption. There should be no change in monitored quantities. #12186, #12187, and #12188 are the 74X, 75X, and 76X versions of this PR, and they have already been approved by Reco. The code fix is satisfactory, and Jenkins tests against baseline CMSSW_8_0_X_2015-10-29-1100 show no significant differences, as expected. The fix was verified for #12186. |
This pull request is fully signed and it will be integrated in one of the next CMSSW_8_0_X IBs (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @Degano, @smuzaffar |
This pull request is fully signed and it will be integrated in one of the next CMSSW_8_0_X IBs (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @Degano, @smuzaffar |
+1 |
80X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting
80X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting.
Refer to https://hypernews.cern.ch/HyperNews/CMS/get/recoDevelopment/1395.html thread.
74X - PR #12186