Merge branch 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git…
Browse files Browse the repository at this point in the history
…/evalenti/linux-soc-thermal

Pull thermal fixes from Eduardo Valentin:
 "A couple of fixes for the thermal subsystem"

* 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal:
  dt-bindings: thermal: Remove "cooling-{min|max}-level" properties
  dt-bindings: thermal: remove no longer needed samsung thermal properties
  • Loading branch information
torvalds committed Apr 20, 2018
2 parents 7e3cb16 + e04907d commit 83beed7
Show file tree
Hide file tree
Showing 2 changed files with 6 additions and 33 deletions.
23 changes: 5 additions & 18 deletions Documentation/devicetree/bindings/thermal/exynos-thermal.txt
Original file line number Diff line number Diff line change
Expand Up @@ -49,19 +49,6 @@ on the SoC (only first trip points defined in DT will be configured):
- samsung,exynos5433-tmu: 8
- samsung,exynos7-tmu: 8

Following properties are mandatory (depending on SoC):
- samsung,tmu_gain: Gain value for internal TMU operation.
- samsung,tmu_reference_voltage: Value of TMU IP block's reference voltage
- samsung,tmu_noise_cancel_mode: Mode for noise cancellation
- samsung,tmu_efuse_value: Default level of temperature - it is needed when
in factory fusing produced wrong value
- samsung,tmu_min_efuse_value: Minimum temperature fused value
- samsung,tmu_max_efuse_value: Maximum temperature fused value
- samsung,tmu_first_point_trim: First point trimming value
- samsung,tmu_second_point_trim: Second point trimming value
- samsung,tmu_default_temp_offset: Default temperature offset
- samsung,tmu_cal_type: Callibration type

** Optional properties:

- vtmu-supply: This entry is optional and provides the regulator node supplying
Expand All @@ -78,7 +65,7 @@ Example 1):
clocks = <&clock 383>;
clock-names = "tmu_apbif";
vtmu-supply = <&tmu_regulator_node>;
#include "exynos4412-tmu-sensor-conf.dtsi"
#thermal-sensor-cells = <0>;
};

Example 2):
Expand All @@ -89,7 +76,7 @@ Example 2):
interrupts = <0 58 0>;
clocks = <&clock 21>;
clock-names = "tmu_apbif";
#include "exynos5440-tmu-sensor-conf.dtsi"
#thermal-sensor-cells = <0>;
};

Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
Expand All @@ -99,7 +86,7 @@ Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
interrupts = <0 184 0>;
clocks = <&clock 318>, <&clock 318>;
clock-names = "tmu_apbif", "tmu_triminfo_apbif";
#include "exynos4412-tmu-sensor-conf.dtsi"
#thermal-sensor-cells = <0>;
};

tmu_cpu3: tmu@1006c000 {
Expand All @@ -108,7 +95,7 @@ Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
interrupts = <0 185 0>;
clocks = <&clock 318>, <&clock 319>;
clock-names = "tmu_apbif", "tmu_triminfo_apbif";
#include "exynos4412-tmu-sensor-conf.dtsi"
#thermal-sensor-cells = <0>;
};

tmu_gpu: tmu@100a0000 {
Expand All @@ -117,7 +104,7 @@ Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
interrupts = <0 215 0>;
clocks = <&clock 319>, <&clock 318>;
clock-names = "tmu_apbif", "tmu_triminfo_apbif";
#include "exynos4412-tmu-sensor-conf.dtsi"
#thermal-sensor-cells = <0>;
};

Note: For multi-instance tmu each instance should have an alias correctly
Expand Down
16 changes: 1 addition & 15 deletions Documentation/devicetree/bindings/thermal/thermal.txt
Original file line number Diff line number Diff line change
Expand Up @@ -55,8 +55,7 @@ of heat dissipation). For example a fan's cooling states correspond to
the different fan speeds possible. Cooling states are referred to by
single unsigned integers, where larger numbers mean greater heat
dissipation. The precise set of cooling states associated with a device
(as referred to by the cooling-min-level and cooling-max-level
properties) should be defined in a particular device's binding.
should be defined in a particular device's binding.
For more examples of cooling devices, refer to the example sections below.

Required properties:
Expand All @@ -69,15 +68,6 @@ Required properties:
See Cooling device maps section below for more details
on how consumers refer to cooling devices.

Optional properties:
- cooling-min-level: An integer indicating the smallest
Type: unsigned cooling state accepted. Typically 0.
Size: one cell

- cooling-max-level: An integer indicating the largest
Type: unsigned cooling state accepted.
Size: one cell

* Trip points

The trip node is a node to describe a point in the temperature domain
Expand Down Expand Up @@ -226,8 +216,6 @@ cpus {
396000 950000
198000 850000
>;
cooling-min-level = <0>;
cooling-max-level = <3>;
#cooling-cells = <2>; /* min followed by max */
};
...
Expand All @@ -241,8 +229,6 @@ cpus {
*/
fan0: fan@48 {
...
cooling-min-level = <0>;
cooling-max-level = <9>;
#cooling-cells = <2>; /* min followed by max */
};
};
Expand Down