Expand Up @@ -117,52 +117,52 @@ The module is installed in A/Cs and humidifiers that are either manufactured or

Listed here are the properties available through the API:

| Property | Read Only | Values | Comment |
|------------------|-----------|----------------------------------------|---------------------------------------|
| f_electricity | x | Integer | |
| f_e_arkgrille | x | 0, 1 | |
| f_e_incoiltemp | x | 0, 1 | |
| f_e_incom | x | 0, 1 | |
| f_e_indisplay | x | 0, 1 | |
| f_e_ineeprom | x | 0, 1 | |
| f_e_inele | x | 0, 1 | |
| f_e_infanmotor | x | 0, 1 | |
| f_e_inhumidity | x | 0, 1 | |
| f_e_inkeys | x | 0, 1 | |
| f_e_inlow | x | 0, 1 | |
| f_e_intemp | x | 0, 1 | |
| f_e_invzero | x | 0, 1 | |
| f_e_outcoiltemp | x | 0, 1 | |
| f_e_outeeprom | x | 0, 1 | |
| f_e_outgastemp | x | 0, 1 | |
| f_e_outmachine2 | x | 0, 1 | |
| f_e_outmachine | x | 0, 1 | |
| f_e_outtemp | x | 0, 1 | |
| f_e_outtemplow | x | 0, 1 | |
| f_e_push | x | 0, 1 | |
| f_filterclean | x | 0, 1 | Does the filter require cleaning |
| f_humidity | x | Integer | Relative humidity percent |
| f_power_display | x | 0, 1 | |
| f_temp_in | x | Decimal | Environment temperature in Fahrenheit |
| f_voltage | x | Integer | |
| t_backlight | | ON, OFF | Turn the display on/off |
| t_device_info | | 0, 1 | |
| t_display_power | | 0, 1 | |
| t_eco | | OFF, ON | Economy mode |
| t_fan_leftright | | OFF, ON | Horizontal air flow |
| t_fan_mute | | OFF, ON | Quite mode |
| t_fan_power | | OFF, ON | Vertical air flow |
| t_fan_speed | | AUTO, LOWER, LOW, MEDIUM, HIGH, HIGHER | Fan Speed |
| t_ftkt_start | | Integer | |
| t_power | | OFF, ON | Power |
| t_run_mode | | OFF, ON | Double frequency |
| t_setmulti_value | | Integer | |
| t_sleep | | STOP, ONE, TWO, THREE, FOUR | Sleep mode |
| t_temp | | Integer | Temperature in Fahrenheit |
| t_temptype | | CELSIUS, FAHRENHEIT | Displayed temperature unit |
| t_temp_eight | | OFF, ON | Eight heat mode |
| t_temp_heatcold | | OFF, ON | Fast cool heat |
| t_work_mode | | FAN, HEAT, COOL, DRY, AUTO | Work mode |
| Property | Read Only | Values | Comment |
|------------------|-----------|----------------------------------------|--------------------------------------------------------------------------|
| f_electricity | x | Integer | |
| f_e_arkgrille | x | 0, 1 | Alarm from cabinet grille protection |
| f_e_incoiltemp | x | 0, 1 | Indoor coil temperature sensor in fault |
| f_e_incom | x | 0, 1 | Indoor and outdoor communication in fault |
| f_e_indisplay | x | 0, 1 | Communication faulty between indoor control panel and display panel |
| f_e_ineeprom | x | 0, 1 | Error in EEPROM of indoor control panel |
| f_e_inele | x | 0, 1 | Communication faulty between indoor control panel and indoor power panel |
| f_e_infanmotor | x | 0, 1 | Indoor fan motor operation abnormal |
| f_e_inhumidity | x | 0, 1 | Indoor humidity sensor in fault |
| f_e_inkeys | x | 0, 1 | Communication faulty between indoor control panel and keyboard plate |
| f_e_inlow | x | 0, 1 | |
| f_e_intemp | x | 0, 1 | Indoor temperature sensor in fault |
| f_e_invzero | x | 0, 1 | Fault found from indoor voltage crossing zero detection |
| f_e_outcoiltemp | x | 0, 1 | The temperature sensor in outdoor coil faulty |
| f_e_outeeprom | x | 0, 1 | Outdoor EEPROM error |
| f_e_outgastemp | x | 0, 1 | Exhaust temperature sensor faulty |
| f_e_outmachine2 | x | 0, 1 | |
| f_e_outmachine | x | 0, 1 | |
| f_e_outtemp | x | 0, 1 | Outdoor ambient temperature sensor faulty |
| f_e_outtemplow | x | 0, 1 | |
| f_e_push | x | 0, 1 | Communication faulty between WiFi control panel and indoor control panel |
| f_filterclean | x | 0, 1 | Does the filter require cleaning |
| f_humidity | x | Integer | Relative humidity percent |
| f_power_display | x | 0, 1 | |
| f_temp_in | x | Decimal | Environment temperature in Fahrenheit |
| f_voltage | x | Integer | |
| t_backlight | | ON, OFF | Turn the display on/off |
| t_device_info | | 0, 1 | |
| t_display_power | | 0, 1 | |
| t_eco | | OFF, ON | Economy mode |
| t_fan_leftright | | OFF, ON | Horizontal air flow |
| t_fan_mute | | OFF, ON | Quite mode |
| t_fan_power | | OFF, ON | Vertical air flow |
| t_fan_speed | | AUTO, LOWER, LOW, MEDIUM, HIGH, HIGHER | Fan Speed |
| t_ftkt_start | | Integer | |
| t_power | | OFF, ON | Power |
| t_run_mode | | OFF, ON | Double frequency |
| t_setmulti_value | | Integer | |
| t_sleep | | STOP, ONE, TWO, THREE, FOUR | Sleep mode |
| t_temp | | Integer | Temperature in Fahrenheit |
| t_temptype | | CELSIUS, FAHRENHEIT | Displayed temperature unit |
| t_temp_eight | | OFF, ON | Eight heat mode |
| t_temp_heatcold | | OFF, ON | Fast cool heat |
| t_work_mode | | FAN, HEAT, COOL, DRY, AUTO | Work mode |

## Multiple Air Conditioners