Notifications
You must be signed in to change notification settings - Fork 422
Spectrum analyzer
egzumer edited this page Dec 20, 2023
·
28 revisions
Press F
+ 5 NOAA
to turn on the Spectrum analyzer.
The current VFO/Memory frequency will be the center frequency of the spectrum sweep
Spectrum analyzer can also be used with ScnRng mode
NOTE: in this mode blacklist is limited to 15 frequecies
-
1
/7
- increases/decreases frequency step between consecutive bars -
4
- toggles the number of bars (channels) in the graph -
2
/8
- increases/decreases frequency step size by which the graph is scrolled with UP/DOWN buttons -
5
- shows a frequency input box for lower sweep frequency (value in MHz,*
- decimal point) -
3
/9
- increases/decreases maximum dB value (vertical scale) -
6
- toggles receiver bandwidth -
*
/F
- increases/decreases squelch level -
0
- toggles modulation type (FM/AM/USB) -
Side Button I
- excludes current frequency from the spectrum scan -
Side Button II
- toggles backlight -
EXIT
- exits to a previous screen/function -
PTT
- switches screen to detail monitoring of last received frequency (see below)
-
M
- Scrolls through the parameters displayed at the bottom of the screen which can be adjusted withUP/DOWN
- LNAs - Short Low Noise Amplifier
- LNA - Low Noise Amplifier
- PGA - Programmable Gain Amplifier
- IF - Intermediate Frequency
-
EXIT
- exits to the previous screen of the spectrum analyzer
- Instruction for the Spectrum Analyzer QuanSheng.UV.K5.Spectrum.analyzer.guide.EN.pdf