Macro: After pressing Snake mode, attachment points stick out in different directions and not attached to the bonds #3919

Closed
Zhirnoff opened this issue Jan 17, 2024 · 4 comments · Fixed by #3911, #4034, #4035 or #4482

Comments

@Zhirnoff
Copy link
Collaborator

Steps to Reproduce

  1. Switch to Macro mode
  2. Make monomers sequence connected by bonds
  3. Hover over monomer and move away mouse cursor when bonds freezes
  4. Press Snake mode

Actual behavior
After pressing Snake mode, attachment points stick out in different directions and not attached to the bonds.
Expected behavior
After pressing Snake mode, bonds are connected to monomers and attachment points do not stick out in different directions.

Screenshots

Recording.2024-01-17.150432.mp4

Desktop (please complete the following information):

  • OS: Windows 11
  • Browser Chrome
  • Version 112.0.5615.138 (Official Build) (64-bit)

Ketcher version
[Version 2.18.0-rc.1]

@Zhirnoff
Copy link
Collaborator Author

Test added to the automation table.

@Zhirnoff
Copy link
Collaborator Author

Zhirnoff commented Feb 9, 2024

Bug is still reproducing
2024-02-09_17h59_15

@NadezhdaPeskun
Copy link

Verified as fixed for CI Version
2.21.0-rc.1 Build at 2024-04-26
Indigo Toolkit
Version 1.20.0-dev.1.25-gafde2b35-wasm32-wasm-clang-12.0.0

OS: Windows 11
Browser Chrome
Version 112.0.5615.138 (Official Build) (64-bit)

@Zhirnoff
Copy link
Collaborator Author

Zhirnoff commented May 7, 2024

Tested on release 2.21.0-rc.2
Fixed.

2024-05-07_16h45_54.mp4