Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Feature pipsolar anh #1084

Merged
merged 10 commits into from
Aug 10, 2021
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Binary file added components/images/pipsolar.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
343 changes: 343 additions & 0 deletions components/pipsolar.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,343 @@
PipSolar PV Inverter
====================

.. seo::
:description: Instructions for setting up PipSolar Compatible PV Inverter in ESPHome.
:image: pipsolar.jpg

The PipSolar component allows you to integrate PIP-compatible Inverters in ESPHome.
It uses :ref:`UART <uart>` for communication.

Once configured, you can use sensors, binary sensors, switches and outputs as described below for your projects.

.. warning::

All functionality is working fine on esp8266 and esp32 chips.
If you configure a lot of the possible sensors etc. from below it could be that you run out of memory (on esp8266).
If you configure more than one if this devices with nearly all sensors etc. you run in a stack-size issue. In this case you have to increase stack size.

.. figure:: images/pipsolar.jpg
:align: center
:width: 50.0%

pip4048 compatible PV Inverter.

Overview
--------

You can connect a wide variety of PV Inverters as long as they provide a serial interface and talk the commands used (at least those you want to use).
A documentation about the communication protocol mostly supported can be found |here|_.

This component will poll the needed polling commands in a loop. If there is a command to send for controlling the inverter this command will be queued and fired as next after the current polling command ends.
There is a buffer to buffer up to 10 commands.

.. |here| replace:: ``here``
.. _here: https://github.com/jblance/mpp-solar/raw/master/docs/PI30_PIP-GK_MK-Protocol.pdf

.. code-block:: yaml

# Example configuration entry
uart:
- id: uart_bus
tx_pin: GPIO18
rx_pin: GPIO19
# most devices use 2400 as baud_rate
baud_rate: 2400

pipsolar:
- uart_id: uart_bus
id: inverter0

Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~

- **id** (**Required**, :ref:`config-id`): The id to use for this pipsolar component.
- **uart_id** (*Optional*): The uart Bus ID

Sensors
-------
.. code-block:: yaml

# Example configuration entry
sensor:
- platform: pipsolar
pipsolar_id: inverter0
grid_rating_voltage:
id: inverter0_grid_rating_voltage
name: inverter0_grid_rating_voltage
grid_rating_current:
id: inverter0_grid_rating_current
name: inverter0_grid_rating_current
ac_output_apparent_power:
id: inverter0_ac_output_apparent_power
name: inverter0_ac_output_apparent_power
ac_output_active_power:
id: inverter0_ac_output_active_power
name: inverter0_ac_output_active_power

Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~
All sensors are normal sensors... so all sensor variables are working to.

- **grid_rating_voltage** (*Optional*): grid rating voltage
- **grid_rating_current** (*Optional*): grid rating current
- **ac_output_rating_voltage** (*Optional*): AC output rating voltage
- **ac_output_rating_frequency** (*Optional*): AC output rating frequency
- **ac_output_rating_current** (*Optional*): AC output rating current
- **ac_output_rating_apparent_power** (*Optional*): AC output rating apparent power
- **ac_output_rating_active_power** (*Optional*): AC output rating active power
- **battery_rating_voltage** (*Optional*): battery rating voltage
- **battery_recharge_voltage** (*Optional*): battery recharge voltage
- **battery_under_voltage** (*Optional*): battery under voltage
- **battery_bulk_voltage** (*Optional*): battery bulk voltage
- **battery_float_voltage** (*Optional*): battery float voltage
- **battery_type** (*Optional*): battery type
- **current_max_ac_charging_current** (*Optional*): current max ac charging current
- **current_max_charging_current** (*Optional*): current max charging current
- **input_voltage_range** (*Optional*): input voltage range
- **output_source_priority** (*Optional*): output source priority
- **charger_source_priority** (*Optional*): charger source priority
- **parallel_max_num** (*Optional*): parallel max num
- **machine_type** (*Optional*): machine type
- **topology** (*Optional*): topology
- **output_mode** (*Optional*): output mode
- **battery_redischarge_voltage** (*Optional*): battery re-discharge voltage
- **pv_ok_condition_for_parallel** (*Optional*): PV OK condition for parallel
- **pv_power_balance** (*Optional*): PV power balance mode

- **grid_voltage** (*Optional*): grid voltage
- **grid_frequency** (*Optional*): grid frequency
- **ac_output_voltage** (*Optional*): ac output voltage
- **ac_output_frequency** (*Optional*): ac output frequency
- **ac_output_apparent_power** (*Optional*): ac output apparent power
- **ac_output_active_power** (*Optional*): ac output active power
- **output_load_percent** (*Optional*): output load percentage
- **bus_voltage** (*Optional*): bus voltage
- **battery_voltage** (*Optional*): battery voltage
- **battery_charging_current** (*Optional*): battery charging current
- **battery_capacity_percent** (*Optional*): battery capacity percent
- **inverter_heat_sink_temperature** (*Optional*): inverter heatsink temperature
- **pv_input_current_for_battery** (*Optional*): pv input current for battery
- **pv_input_voltage** (*Optional*): pv input voltage
- **battery_voltage_scc** (*Optional*): battery voltage from scc
- **battery_discharge_current** (*Optional*): battery discharge current
- **add_sbu_priority_version** (*Optional*): add sbu priority status
- **configuration_status** (*Optional*): configuration status
- **scc_firmware_version** (*Optional*): scc firmware version
- **battery_voltage_offset_for_fans_on** (*Optional*): battery voltage offset for fans on
- **eeprom_version** (*Optional*): eeprom version
- **pv_charging_power** (*Optional*): pc charging power

Binary Sensors
--------------
.. code-block:: yaml

# Example configuration entry
binary_sensor:
- platform: pipsolar
pipsolar_id: inverter0
add_sbu_priority_version:
id: inverter0_add_sbu_priority_version
name: inverter0_add_sbu_priority_version
configuration_status:
id: inverter0_configuration_status
name: inverter0_configuration_status

Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~
All sensors are normal binary sensors... so all binary sensor variables are working to.

- **add_sbu_priority_version** (*Optional*): add sbu priority version
- **configuration_status** (*Optional*): configuration status
- **scc_firmware_version** (*Optional*): scc firmware version
- **load_status** (*Optional*): load status
- **battery_voltage_to_steady_while_charging** (*Optional*): battery voltage to steady while charging
- **charging_status** (*Optional*): charging status
- **scc_charging_status** (*Optional*): scc charging status
- **ac_charging_status** (*Optional*): ac charging status
- **charging_to_floating_mode** (*Optional*): charging to floating mode
- **switch_on** (*Optional*): switch on
- **dustproof_installed** (*Optional*): dustproof installed
- **silence_buzzer_open_buzzer** (*Optional*): silence buzzer open buzzer
- **overload_bypass_function** (*Optional*): overload bypass function
- **lcd_escape_to_default** (*Optional*): lcd escape to default
- **overload_restart_function** (*Optional*): overload restart function
- **over_temperature_restart_function** (*Optional*): over temperature restart function
- **backlight_on** (*Optional*): backlight on
- **alarm_on_when_primary_source_interrupt** (*Optional*): alarm on when primary source interrupt
- **fault_code_record** (*Optional*): fault code record
- **power_saving** (*Optional*): power saving

- **warnings_present** (*Optional*): warnings present
- **faults_present** (*Optional*): faults present
- **warning_power_loss** (*Optional*): warning power loss
- **fault_inverter_fault** (*Optional*): fault inverter fault
- **fault_bus_over** (*Optional*): fault bus over
- **fault_bus_under** (*Optional*): fault bus under
- **fault_bus_soft_fail** (*Optional*): fault bus soft fail
- **warning_line_fail** (*Optional*): warning line fail
- **fault_opvshort** (*Optional*): fault opvshort
- **fault_inverter_voltage_too_low** (*Optional*): fault inverter voltage too low
- **fault_inverter_voltage_too_high** (*Optional*): fault inverter voltage too high
- **warning_over_temperature** (*Optional*): warning over temperature
- **warning_fan_lock** (*Optional*): warning fan lock
- **warning_battery_voltage_high** (*Optional*): warning battery voltage high
- **warning_battery_low_alarm** (*Optional*): warning battery low alarm
- **warning_battery_under_shutdown** (*Optional*): warning battery under shutdown
- **warning_battery_derating** (*Optional*): warning battery derating
- **warning_over_load** (*Optional*): warning over load
- **warning_eeprom_failed** (*Optional*): warning eeprom failed
- **fault_inverter_over_current** (*Optional*): fault inverter over current
- **fault_inverter_soft_failed** (*Optional*): fault inverter soft failed
- **fault_self_test_failed** (*Optional*): fault_self_test_failed
- **fault_op_dc_voltage_over** (*Optional*): fault op dc voltage over
- **fault_battery_open** (*Optional*): fault battery open
- **fault_current_sensor_failed** (*Optional*): fault current sensor failed
- **fault_battery_short** (*Optional*): fault battery short
- **warning_power_limit** (*Optional*): warning power limit
- **warning_pv_voltage_high** (*Optional*): warning pv voltage high
- **fault_mppt_overload** (*Optional*): fault mppt overload
- **warning_mppt_overload** (*Optional*): warning mppt overload
- **warning_battery_too_low_to_charge** (*Optional*): warning battery too low to charge
- **fault_dc_dc_over_current** (*Optional*): fault dc dc over current
- **fault_code** (*Optional*): fault code
- **warnung_low_pv_energy** (*Optional*): warnung low pv energy
- **warning_high_ac_input_during_bus_soft_start** (*Optional*): warning high ac input during bus soft start
- **warning_battery_equalization** (*Optional*): warning battery equalization

Text Sensors
------------
.. code-block:: yaml

# Example configuration entry
text_sensor:
- platform: pipsolar
pipsolar_id: inverter0
device_mode:
id: inverter0_device_mode
name: inverter0_device_mode
last_qpigs:
id: inverter0_last_qpigs
name: inverter0_last_qpigs
last_qpiri:

Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~
All sensors are normal text sensors... so all text sensor variables are working to.

- **device_mode** (*Optional*): device mode response
- **last_qpigs** (*Optional*): last qpigs reponse
- **last_qpiri** (*Optional*): last qpiri reponse
- **last_qmod** (*Optional*): last qmod reponse
- **last_qflag** (*Optional*): last qflag reponse
- **last_qpiws** (*Optional*): last qpiws reponse
- **last_qt** (*Optional*): last qt reponse
- **last_qmn** (*Optional*): last qmn reponse

Switches
--------
Not all possible switches are exposed as they lead to the possibility to make serious damage. They should only be set at the physical device itself.

.. code-block:: yaml

# Example configuration entry
switch:
- platform: pipsolar
pipsolar_id: inverter0
output_source_priority_utility:
name: inverter0_output_source_priority_utility
output_source_priority_solar:
name: inverter0_output_source_priority_solar
output_source_priority_battery:
name: inverter0_output_source_priority_battery
input_voltage_range:
name: inverter0_input_voltage_range
pv_ok_condition_for_parallel:
name: inverter0_pv_ok_condition_for_parallel
pv_power_balance:
name: inverter0_pv_power_balance

Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~
All sensors are normal text sensors... so all text sensor variables are working to.

- **output_source_priority_utility** (*Optional*): output source priority utility
- **output_source_priority_solar** (*Optional*): output source priority solar
- **output_source_priority_battery** (*Optional*): output source priority battery
- **input_voltage_range** (*Optional*): input voltage range
- **pv_ok_condition_for_parallel** (*Optional*): pv ok condition for parallel
- **pv_power_balance** (*Optional*): pv power balance

Outputs
--------------
Not all possible outputs are exposed as they lead to the possibility to make serious damage. They should only be set at the physical device itself.

.. code-block:: yaml

# Example configuration entry
output:
- platform: pipsolar
pipsolar_id: inverter0
battery_recharge_voltage:
id: inverter0_battery_recharge_voltage_out

Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~
All sensors are normal text sensors... so all text sensor variables are working to.

- **battery_recharge_voltage** (*Optional*): battery recharge voltage;

- **possible_values** (*Optional*,list): a list of possible values default: 44.0,45.0,46.0,47.0,48.0,49.0,50.0,51.0
- **battery_under_voltage** (*Optional*): battery under voltage;

- **possible_values** (*Optional*,list): a list of possible values default: 40.0,40.1,42,43,44,45,46,47,48.0
- **battery_float_voltage** (*Optional*): battery float voltage;

- **possible_values** (*Optional*,list): a list of possible values default: 48.0,49.0,50.0,51.0
- **battery_type** (*Optional*): battery type;

- **possible_values** (*Optional*,list): a list of possible values default: 0,1,2
- **current_max_ac_charging_current** (*Optional*): current max ac charging current;

- **possible_values** (*Optional*,list): a list of possible values default: 2,10,20
- **current_max_charging_current** (*Optional*): current max charging current;

- **possible_values** (*Optional*,list): a list of possible values default: 10,20,30,40
- **output_source_priority** (*Optional*): output source priority;

- **possible_values** (*Optional*,list): a list of possible values default: 0,1,2
- **charger_source_priority** (*Optional*): charger source priority;

- **possible_values** (*Optional*,list): a list of possible values default: 0,1,2,3
- **battery_redischarge_voltage** (*Optional*): battery redischarge voltage;

- **possible_values** (*Optional*,list): a list of possible values default: 00.0,48.0,49,50.0,51.0,52,53,54,55,56,57,58

.. _pipsolaroutput_set_level_action:

``output.pipsolar.set_level`` Action
------------------------------------

To use your outputs in :ref:`automations <automation>` or templates, you can use this action to set the
target level of the output.

.. code-block:: yaml

on_...:
then:
- output.pipsolar.set_level:
id: my_pipsolar_output
level: 48.0


Configuration options:

- **id** (**Required**, :ref:`config-id`): The ID of the output.
- **level** (*Optional*, percentage, :ref:`templatable <config-templatable>`): The target level.


See Also
--------

- :ref:`uart`
- :ghedit:`Edit`
Binary file added images/pipsolar.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
1 change: 1 addition & 0 deletions index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -449,6 +449,7 @@ Misc Components
Exposure Notifications, components/exposure_notifications, exposure_notifications.png
RTTTL Buzzer, components/rtttl, buzzer.jpg
Prometheus, components/prometheus, prometheus.svg
PipSolar - compatible PV Inverter, components/pipsolar, pipsolar.jpg
Grow Fingerprint Reader, components/fingerprint_grow, fingerprint.svg

Additional Custom Components
Expand Down