it's my fault. All working fine. |
No, problem does't solved. It maybe solved if use collectors in cookbook, because if used collectors initscript is rewrite. Default initscript got error if try to restart ganglia-monitor on ubuntu 14.04. |
it's happened because in ubuntu package ganglia-monitor v3.6.0 there is init config for upstart which have a name of pidfile 'ganglia0monitor.pid', while in init.d script have a pidfile name gmond.pid. |
I'm also having this exact same issue. Is it now solved? |
+1 I shortened the name and now the -name value passed from start-stop doesn't match any process names. It has the right pid file and pid but doesn't use it. |
If we have the pid file why bother with the --name? Plus name seems to to be limited to 15 chars and cookbook prepends ganglia-monitor. Mine was ganglia-monitor-mesos-master !!! Just take the --name no? |
if you lost pid file than start-stop-daemon can to stop process by name. |
I'll try it later today.
|
in package ganglia-monitor (3.6.0) on ubuntu 14.04 initscript return exit code 1 when restart because upstart run process fastly than initscript. Generally it error of initscript which return exit code 1 when application already run.