The applet always displays 0 devices
- Check out if arpalert is running (
ps ax|grep arpalert
). If not take a look at /var/log/arpalert.log - Check out if the dbus service is running:
ps ax|grep arpalert-service
- Send a message to the applet and see if the status text is updated:
qdbus --system org.arpsentinel /org/arpsentinel sendAlert "1" "2" "3" "4" "5" "6"
- or:
gdbus call --system --dest org.arpsentinel --object-path /org/arpsentinel --method org.arpsentinel.alerts.sendAlert "1" "2" "3" "4" "5" "6"
- Restart arpalert:
sudo service arpalert restart || sudo /etc/init.d/arpalert restart
- Check out if arpalert is running (
-
The applet fails to load
- Check if the DBUS Service is running (
ps ax|grep arpalert-service
). - If it's not, launch it manually (
~/.arpsentinel-applet/bin/arpalert-service.py
) and add the applet afterwards. - Remember that
arpalert
must be installed and running. - Once you've executed arpalert-service.py manually, run this command:
~/.arpsentinel-applet/bin/arpalert.sh 1 2 3 4 5 6
, and see again if the DBUS service is running (ps ax|grep arpalert-service
). - If it's, add the applet to the panel.
- Check if the DBUS Service is running (
-
Gathering logs when reporting an issue:
- Press ALT+F2 and type lg
- Press Windows key + l, and select the extension tab.
tail -f ~/.cinnamon/glass.log